Produtos

Technical Parameters

Power SupplyDC24V, AC24V, AC110V, AC220V, AC380V
Standard Torque/Time400 Nm/30 S
Optional Torque/Time200Nm/15S, 400Nm/60S
Rotation Angle RangeAdjustable from 0 to 90 degrees
Motor powerDC24V:70W/5.13A
AC24V:90W/6.80A
AC110V:90W/1.12A
AC220V:90W/0.57A
AC380V:40W/0.29A
Control CircuitType A/B/C/D/E/F/G/H
Weight9.5Kg
Insulation Resistance DC24V/AC24V: 100MΩ/250VDC
AC110V/AC220V/AC380V: 100MΩ/500VDC
Withstand VoltageDC24V/AC24V: 500VAC for 1 minute
Water Proof LevelIP67
Installation360 ° installation at any angle
Electrical InterfaceG1/2 waterproof cable connector: one power line and one signal line each
Working Temperature-25℃ ~ +55℃
Optional FunctionOver torque protection, dehumidification heater, convex indicator, operating handwheel
Modulation Parameters
Sinal de entrada4~20mA, 0~10V arbitrary calibration
output Signal4~20mA, 0~10V arbitrary calibration
Bus485/Modbus/CAN
Internet of ThingsWIFI/LoRA/4G
Basic Error≤±1%
Return Error≤1%
HysteresisAdjustable from 0.5% to 5.0%
Reposition Times0 times
Repeatability Error≤1%

Dimensions

华易普通型执行器安装形式 | DCL Electrical Actuator Install Type
华易执行器 DCL-20 DCL-40 DCL-60 外型安装尺寸

Application Circuit

Modulação

E - Modulação com uma unidade de controle

  • Entrada: 4~20mA / 0~10V
  • Saída: 4~20mA / 0~10V
  • Barramento de campo: Modbus / CAN
  • IIoT: Wi-Fi/LoRa/4G DTU

 

Connecting Details:

  1. Connecting AC85-220V supply power line to L and neutral to N.
  2. Connecting 4-20mA/2-10V input signal source from control system to input-/+.
  3. Connecting Output -/+ to the system to send out the real-time valve position.

Aproximação e posicionamento

F - Com uma unidade de posicionamento

  • Atuador de controle para abrir ou fechar com K
  • The real-time valve position will be send out as a 4-20mA signal.

 

Connecting Details:

  1. Connecting AC85-220V supply power line to L and neutral to N.
  2. Switch AC85-220V line to CLOSE(P2) to close the valve.
  3. Switch AC85-220V line to OPEN(P3) to open the valve.
  4. Connecting Output -/+ to the system to send out the real-time valve position.

C - Com um potenciômetro de 1KΩ/500Ω

  • Atuador de controle para abrir ou fechar com K
  • A posição da válvula em tempo real será enviada como um valor de resistência do potenciômetro.

 

Connecting Details:

  1. Connecting AC85-220V supply power neutral to P1.
  2. Switch AC85-220V line to CLOSE(P2) to close the valve
  3. Switch AC85-220V line to OPEN(P3) to open the valve.
  4. P4 is the low side of potentiometer that is normally connected to signal GND.
  5. Connecting signal input of  control system to P5. The resistance value between P4 and P5 will become higher as actuator opening the valve, while the value between P5 and P6 will become lower.
  6. P6 is the high side of potentiometer that is normally connected to signal power.
  7. Connect earth to P7.

D - Com um potenciômetro e feedback de posição final

  • Atuador de controle para abrir ou fechar com K
  • A posição da válvula em tempo real será enviada como um valor de resistência do potenciômetro.
  • O terminal de saída de posição final ABERTO/FECHAR enviará o evento como um sinal passivo quando a posição final for atingida.

 

Connecting Details:

  1. Connecting AC85-220V supply power neutral to P1.
  2. Switch AC85-220V line to CLOSE(P2) to close the valve
  3. Switch AC85-220V line to OPEN(P3) to open the valve.
  4. P4 is the COM for passive contact signal of end-position OPEN/CLOSE which is normally connected to signal GND.
  5. P5 is end-position OPEN terminal which will be connected to COM when actuator reached end-position of open.
  6. P6 is end-position CLOSE terminal which will be connected to COM when actuator reached end-position of close.
  7. P7 is the low side of potentiometer that is normally connected to signal GND.
  8. Connecting signal input of  control system to P8. The resistance value between P7 and P8 will become higher as actuator opening the valve, while the value between P8 and P9 will become lower.
  9. P9 is the high side of potentiometer that is normally connected to signal power.
  10. Connect earth to P12.

LIGADO - DESLIGADO

A - Com 2 saídas de sinal de posição final ativas

  • Atuador de controle para abrir ou fechar com K
  • O terminal de saída da posição final ABERTO/FECHAR enviará o evento como um sinal ativo de 220 VCA quando a posição final for atingida.

 

Connecting Details:

  1. Connecting AC85-220V supply power neutral to P1.
  2. Switch AC85-220V line to CLOSE(P2) to close the valve
  3. Switch AC85-220V line to OPEN(P3) to open the valve.
  4. P5 is end-position OPEN terminal which will output a AC220V source which can be used to drive an Indication light when actuator reached end-position of open.
  5. P6 is end-position OPEN terminal which will output a AC220V source which can be used to drive an Indication light when actuator reached end-position of close.
  6. Connect earth to P7.

B - Com 2 interruptores passivos de posição final

  • Atuador de controle para abrir ou fechar com K
  • O terminal de saída de posição final ABERTO/FECHAR enviará o evento como um sinal passivo quando a posição final for atingida.

 

Connecting Details:

  1. Connecting AC85-220V supply power neutral to P1.
  2. Switch AC85-220V line to CLOSE(P2) to close the valve
  3. Switch AC85-220V line to OPEN(P3) to open the valve.
  4. P4 is the COM for passive contact signal of end-position OPEN/CLOSE which is normally connected to signal GND.
  5. P5 is end-position OPEN terminal which will be connected to COM when actuator reached end-position of open.
  6. P6 is end-position CLOSE terminal which will be connected to COM when actuator reached end-position of close.
  7. Connect earth to P7.

G - Motor CC com 2 interruptores de posição final

  • O atuador de controle abre ou fecha de acordo com a direção da alimentação elétrica entre os terminais 1 e 2.
  • O terminal de saída de posição final ABERTO/FECHAR enviará o evento como um sinal passivo quando a posição final for atingida.

 

Connecting Details:

  1. Connecting DC24V+ to P1 and DC24V- to P2 to close the valve.
  2. Connecting DC24V+ to P2 and DC24V- to P1 to close the valve.
  3. P3 is the COM for passive contact signal of end-position OPEN/CLOSE which is normally connected to signal GND.
  4. P4 is end-position OPEN terminal which will be connected to COM when actuator reached end-position of open.
  5. P5 is end-position CLOSE terminal which will be connected to COM when actuator reached end-position of close.
  6. Connect earth to P7.

H - Motor trifásico de 380 VCA com 2 interruptores de posição final

  • Atuador de controle para abrir ou fechar por meio de um inversor externo, alterando assim a fase da energia fornecida.
  • O terminal de saída de posição final ABERTO/FECHAR enviará o evento como um sinal passivo quando a posição final for atingida.

 

Connecting Details:

  1. Connecting a 3 phase AC380V inverter output to P1, P2 and P3, then the actuator can be controlled to open or close the valve by change the 3 phase order.
  2. Connecting AC380V neutral to N(P4).
  3. P5 is used for cooperating with an external switch to control the inverter 3 phase order. This terminal is connected to N(P4) when actuator is not in end-position of CLOSE and disconnected from N(P4) after actuator reached end-position of CLOSE.
  4. P6 is used for cooperating with an external switch to control the inverter 3 phase order. This terminal is connected to N(P4) when actuator is not in end-position of OPEN and disconnected from N(P4) after actuator reached end-position of OPEN.
  5. P7 is the COM for passive contact signal of end-position OPEN/CLOSE which is normally connected to signal GND.
  6. P8 is end-position OPEN terminal which will be connected to COM when actuator reached end-position of open.
  7. P9 is end-position CLOSE terminal which will be connected to COM when actuator reached end-position of close.
  8. Connect earth to P12.

Observação:

  • O circuito dentro da caixa tracejada é o circuito interno do atuador. Já o circuito externo demonstra a conexão elétrica para utilização do atuador.
  • Caso tenha outros requisitos específicos sobre a conexão do circuito, não hesite em contatar nosso suporte técnico. 

Choose another actuator with different torque​

50 Nm/20 S

————————–

Opcional com

20 Nm/4 S

30 Nm/10 S

50 Nm/60 S

50 Nm/100 S

100 Nm/30 S

————————–

Opcional com

50 Nm/15 S

100 Nm/60 S

 

 

200 Nm/30 S

————————–

Opcional com

100 Nm/15 S

200 Nm/60 S

 

 

400 Nm/30 S

————————–

Opcional com

200 Nm/15 S

400 Nm/60 S

 

 

Solicitação de Cotação

Clique em "Enviar" agora. Confirmaremos o número do modelo do produto e o distribuidor local com você posteriormente e, em seguida, enviaremos a cotação.

WhatsApp

Escaneie o código QR para conversar com nosso engenheiro agora mesmo...

Solicitação de Cotação

Clique em "Enviar" agora. Confirmaremos o número do modelo do produto e o distribuidor local com você posteriormente e, em seguida, enviaremos a cotação.

WhatsApp

Escaneie o código QR para conversar com nosso engenheiro agora mesmo...

Solicitação de Cotação

Clique em "Enviar" agora. Confirmaremos o número do modelo do produto e o distribuidor local com você posteriormente e, em seguida, enviaremos a cotação.

WhatsApp

Escaneie o código QR para conversar com nosso engenheiro agora mesmo...

🤝 Seja nosso parceiro para construir sua marca

✅ ODM

  • Seu logotipo e embalagem
  • Formatos de saída personalizados (4-20mA, RS485 Modbus, HART, etc.)
  • Alterações na cor ou na etiqueta da caixa
  • Versões compatíveis com a nuvem (opcional)

✅ OEM

  • Siga rigorosamente o projeto e as especificações.
  • Confidencialidade total e proteção de propriedade intelectual.
  • Produção de alta qualidade a preços competitivos
  • Produção em pequenos lotes ou em grande escala
  • 🏭 Pesquisa e Desenvolvimento e Fabricação InternasDa placa de circuito impresso à caixa, tudo em um só lugar.
  • 💬 Suporte multilíngueEngenheiros e equipe de vendas que falam inglês.

  • ⚙️ Quantidade mínima de encomenda flexívelApoio tanto para startups quanto para marcas globais.

  • 🚀 Prototipagem rápidaEntrega da amostra em 7 a 10 dias.

 Entre em contato conosco hoje mesmo Para solicitar um catálogo de produtos ou obter uma consulta gratuita.

Solicitação de Cotação

Enviar consulta

WhatsApp

Escaneie o código QR para conversar com nosso engenheiro agora mesmo...

Contate-nos

Telefone

(+86) 130 2633 1611

WhatsApp

Ken Bryan

即时客服图标 | Ícone de mensagem ao vivo

No chat do site

Clique no ícone no canto inferior direito para conversar conosco...