Technical Parameters
| Power Supply | DC24V, AC24V, AC110V, AC220V, AC380V |
| Standard Torque/Time | 200Nm /30S |
| Optional Torque/Time | 100Nm/15S, 200Nm/60S |
| Rotation Angle Range | Adjustable from 0 to 90 degrees |
| Motor Power/Current | DC24V:35W/3.57A AC24V:40W/3.65A AC110V:40W/0.65A AC220V:40W/0.37A AC380V:30W/0.15A |
| Control Circuit | Type A/B/C/D/E/F/G/H |
| Weight | 9Kg |
| Insulation Resistance | DC24V/AC24V: 100MΩ/250VDC AC110V/AC220V/AC380V: 100MΩ/500VDC |
| Withstand Voltage | DC24V/AC24V: 500VAC for 1 minute |
| Water Proof Level | IP67 |
| Installation | 360 ° installation at any angle |
| Electrical Interface | G1/2 waterproof cable connector: one power line and one signal line each |
| Working Temperature | -25℃ ~ +55℃ |
| Optional Function | Over torque protection, dehumidification heater, convex indicator, operating handwheel |
| Modulation Parameters | |
| Signal d'entrée | 4~20mA, 0~10V arbitrary calibration |
| output Signal | 4~20mA, 0~10V arbitrary calibration |
| Bus | 485/Modbus/CAN |
| Internet of Things | WIFI/LoRA/4G |
| Basic Error | ≤±1% |
| Return Error | ≤1% |
| Hysteresis | Adjustable from 0.5% to 5.0% |
| Reposition Times | 0 times |
| Repeatability Error | ≤1% |
Dimensions
Application Circuit
Modulation
E - Modulation avec une unité de contrôle
- Entrée : 4~20 mA / 0~10 V
- Sortie : 4~20 mA / 0~10 V
- Field Bus:Modbus / CAN
- IIot:WIFI/LoRA/4G DTU
Détails de connexion :
- Raccordement de la ligne d'alimentation AC85-220V à L et du neutre à N.
- Connexion de la source de signal d'entrée 4-20mA/2-10V du système de contrôle à l'entrée-/+.
- Connectez la sortie -/+ au système pour envoyer la position de la vanne en temps réel.
Inching and positioning
F - With a positioning unit
- Control actuator to open or close with K
- The real-time valve position will be send out as a 4-20mA signal.
Détails de connexion :
- Raccordement de la ligne d'alimentation AC85-220V à L et du neutre à N.
- Switch AC85-220V line to CLOSE(P2) to close the valve.
- Switch AC85-220V line to OPEN(P3) to open the valve.
- Connectez la sortie -/+ au système pour envoyer la position de la vanne en temps réel.
C - With a 1KΩ/500Ω potentiometer
- Control actuator to open or close with K
- The real-time valve position will be send out as a potentiometer resistance value
Détails de connexion :
- Connecting AC85-220V supply power neutral to P1.
- Switch AC85-220V line to CLOSE(P2) to close the valve
- Switch AC85-220V line to OPEN(P3) to open the valve.
- P4 is the low side of potentiometer that is normally connected to signal GND.
- Connecting signal input of control system to P5. The resistance value between P4 and P5 will become higher as actuator opening the valve, while the value between P5 and P6 will become lower.
- P6 is the high side of potentiometer that is normally connected to signal power.
- Connect earth to P7.
D - With a potentiometer and end-position feedback
- Control actuator to open or close with K
- The real-time valve position will be send out as a potentiometer resistance value
- The output terminal of end-position OPEN/CLOSE will send out the event as a passive signal form when the end-position was reached.
Détails de connexion :
- Connecting AC85-220V supply power neutral to P1.
- Switch AC85-220V line to CLOSE(P2) to close the valve
- Switch AC85-220V line to OPEN(P3) to open the valve.
- P4 is the COM for passive contact signal of end-position OPEN/CLOSE which is normally connected to signal GND.
- P5 is end-position OPEN terminal which will be connected to COM when actuator reached end-position of open.
- P6 is end-position CLOSE terminal which will be connected to COM when actuator reached end-position of close.
- P7 is the low side of potentiometer that is normally connected to signal GND.
- Connecting signal input of control system to P8. The resistance value between P7 and P8 will become higher as actuator opening the valve, while the value between P8 and P9 will become lower.
- P9 is the high side of potentiometer that is normally connected to signal power.
- Connect earth to P12.
ON - OFF
A - With 2 active end-position signal outputs
- Control actuator to open or close with K
- The output terminal of end-position OPEN/CLOSE will send out the event as a 220VAC active signal form when the end-position was reached.
Détails de connexion :
- Connecting AC85-220V supply power neutral to P1.
- Switch AC85-220V line to CLOSE(P2) to close the valve
- Switch AC85-220V line to OPEN(P3) to open the valve.
- P5 is end-position OPEN terminal which will output a AC220V source which can be used to drive an Indication light when actuator reached end-position of open.
- P6 is end-position OPEN terminal which will output a AC220V source which can be used to drive an Indication light when actuator reached end-position of close.
- Connect earth to P7.
B - With 2 passive end-position switches
- Control actuator to open or close with K
- The output terminal of end-position OPEN/CLOSE will send out the event as a passive signal form when the end-position was reached.
Détails de connexion :
- Connecting AC85-220V supply power neutral to P1.
- Switch AC85-220V line to CLOSE(P2) to close the valve
- Switch AC85-220V line to OPEN(P3) to open the valve.
- P4 is the COM for passive contact signal of end-position OPEN/CLOSE which is normally connected to signal GND.
- P5 is end-position OPEN terminal which will be connected to COM when actuator reached end-position of open.
- P6 is end-position CLOSE terminal which will be connected to COM when actuator reached end-position of close.
- Connect earth to P7.
G - DC motor with 2 end-position switches
- Control actuator to open or close by the supply power direction between the terminal 1 and 2
- The output terminal of end-position OPEN/CLOSE will send out the event as a passive signal form when the end-position was reached.
Détails de connexion :
- Connecting DC24V+ to P1 and DC24V- to P2 to close the valve.
- Connecting DC24V+ to P2 and DC24V- to P1 to close the valve.
- P3 is the COM for passive contact signal of end-position OPEN/CLOSE which is normally connected to signal GND.
- P4 is end-position OPEN terminal which will be connected to COM when actuator reached end-position of open.
- P5 is end-position CLOSE terminal which will be connected to COM when actuator reached end-position of close.
- Connect earth to P7.
H - 3 phase 380VAC motor with 2 end-position switches
- Control actuator to open or close by an external inverter to change the phase of supply power.
- The output terminal of end-position OPEN/CLOSE will send out the event as a passive signal form when the end-position was reached.
Détails de connexion :
- Connecting a 3 phase AC380V inverter output to P1, P2 and P3, then the actuator can be controlled to open or close the valve by change the 3 phase order.
- Connecting AC380V neutral to N(P4).
- P5 is used for cooperating with an external switch to control the inverter 3 phase order. This terminal is connected to N(P4) when actuator is not in end-position of CLOSE and disconnected from N(P4) after actuator reached end-position of CLOSE.
- P6 is used for cooperating with an external switch to control the inverter 3 phase order. This terminal is connected to N(P4) when actuator is not in end-position of OPEN and disconnected from N(P4) after actuator reached end-position of OPEN.
- P7 is the COM for passive contact signal of end-position OPEN/CLOSE which is normally connected to signal GND.
- P8 is end-position OPEN terminal which will be connected to COM when actuator reached end-position of open.
- P9 is end-position CLOSE terminal which will be connected to COM when actuator reached end-position of close.
- Connect earth to P12.
Note:
- Le circuit à l'intérieur du cadre en pointillés représente le circuit interne de l'actionneur. Le circuit extérieur illustre le branchement électrique nécessaire à l'utilisation de l'actionneur.
- Si vous avez d'autres exigences spécifiques concernant le raccordement du circuit, n'hésitez pas à contacter notre assistance technique.
Choose another actuator with different torque
50 Nm/20 s
————————–
Optionnel avec
20 Nm/4 S
30 Nm/10 s
50 Nm/60 s
50Nm/100S
100 Nm/30 s
————————–
Optionnel avec
50 Nm/15 s
100 Nm/60 s
200 Nm/30 s
————————–
Optionnel avec
100 Nm/15 s
200 Nm/60 s
400 Nm/30 s
————————–
Optionnel avec
200 Nm/15 s
400 Nm/60 s
1000Nm/30S
————————–
Optionnel avec
1000Nm/30S
500Nm/15S