{"id":6041,"date":"2023-08-03T20:58:30","date_gmt":"2023-08-03T12:58:30","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6041"},"modified":"2025-03-27T09:10:32","modified_gmt":"2025-03-27T09:10:32","slug":"dcl-gey-24v-modulating","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/tr_tr\/destek\/bay-aktuator\/dcl-gey-24v-modulasyonlu","title":{"rendered":"DC24V Mod\u00fclasyonlu Akt\u00fcat\u00f6rlerde S\u0131k G\u00f6r\u00fclen Ar\u0131zalar ve Sorun Giderme Y\u00f6ntemleri"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6041\" class=\"elementor elementor-6041\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2e3fdf7 e-con-full e-flex e-con e-child\" data-id=\"2e3fdf7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-47c2169 elementor-widget elementor-widget-text-editor\" data-id=\"47c2169\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bu k\u0131lavuz, DC24V ile \u00e7al\u0131\u015fan DCL Patlamaya Dayan\u0131kl\u0131 Seri \/ Hava Ko\u015fullar\u0131na Dayan\u0131kl\u0131 Seri \/ H\u0131zl\u0131 D\u00f6n\u00fc\u015fl\u00fc Seri mod\u00fclasyonlu akt\u00fcat\u00f6rlerin a\u015fa\u011f\u0131daki modelleri i\u00e7in ge\u00e7erlidir:<\/p><ul><li><p><strong>Hava ko\u015fullar\u0131na dayan\u0131kl\u0131 Akt\u00fcat\u00f6r<\/strong>: DCL-02GEY, DCL-05GEY, DCL-10GEY, DCL-20GEY, DCL-40GEY, DCL-60GEY<\/p><\/li><li><p><strong>Patlamaya dayan\u0131kl\u0131 Akt\u00fcat\u00f6r<\/strong>: DCL-Ex05GEY, DCL-Ex10GEY, DCL-Ex20GEY, DCL-Ex40GEY, DCL-Ex60GEY<\/p><\/li><\/ul><p>Bu k\u0131lavuzla ilgili daha fazla yard\u0131ma ihtiyac\u0131n\u0131z olursa l\u00fctfen bana bildirin!<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03ae46d elementor-widget elementor-widget-image\" data-id=\"03ae46d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"696\" height=\"600\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-product-line.webp\" class=\"attachment-full size-full wp-image-4829\" alt=\"DCL \u534e\u6613\u667a\u63a7 \u6267\u884c\u5668 \u4ea7\u54c1\u7ebf | DCL Akt\u00fcat\u00f6rler\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dc41cb3 elementor-widget elementor-widget-heading\" data-id=\"dc41cb3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Elektrik haznesinin kapa\u011f\u0131n\u0131 a\u00e7\u0131n.<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4f350d elementor-widget elementor-widget-text-editor\" data-id=\"b4f350d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Kontrol odas\u0131n\u0131n d\u0131\u015f kapa\u011f\u0131ndaki 4 sabitleme vidas\u0131n\u0131 s\u00f6kmek i\u00e7in y\u0131ld\u0131z tornavida kullan\u0131n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3417eab elementor-widget elementor-widget-image\" data-id=\"3417eab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"500\" height=\"593\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/08\/servo-module-cover.webp\" class=\"attachment-full size-full wp-image-6044\" alt=\"DCL Veri Taban\u0131\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cea5b49 elementor-widget elementor-widget-heading\" data-id=\"cea5b49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Ar\u0131za G\u00f6sterge I\u015f\u0131\u011f\u0131n\u0131n Durumunu Kontrol Edin<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-293ccda elementor-widget elementor-widget-image\" data-id=\"293ccda\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"600\" height=\"609\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/08\/gey-servo-module-interface.webp\" class=\"attachment-full size-full wp-image-6046\" alt=\"DCL 24V GEY Kontrol Paneli\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db918c7 elementor-widget elementor-widget-text-editor\" data-id=\"db918c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0<\/p><p><strong>2. Ar\u0131za G\u00f6sterge I\u015f\u0131\u011f\u0131n\u0131n Durumunu Kontrol Edin<\/strong><\/p><p>G\u00fcc\u00fc a\u00e7\u0131k tutun ve akt\u00fcat\u00f6r kontrol mod\u00fcl\u00fcndeki (Model: SF-ZCY) ar\u0131za g\u00f6sterge \u0131\u015f\u0131klar\u0131n\u0131 kontrol edin:<\/p><ul><li><p><strong>L1: Ye\u015fil<\/strong> \u2013 G\u00fc\u00e7 g\u00f6stergesi. G\u00fc\u00e7 kayna\u011f\u0131 servo kontrol \u00fcnitesinin g\u00fc\u00e7 terminallerine (\u2013, +) ba\u011fland\u0131\u011f\u0131nda \u0131\u015f\u0131k yanar.<\/p><\/li><li><p><strong>L2: K\u0131rm\u0131z\u0131<\/strong> \u2013 Giri\u015f sinyali ar\u0131za g\u00f6stergesi. Giri\u015f sinyali ar\u0131zaland\u0131\u011f\u0131nda \u0131\u015f\u0131k yanar.<\/p><\/li><li><p><strong>L3: K\u0131rm\u0131z\u0131<\/strong> \u2013 Konum alg\u0131lama devresi ar\u0131za g\u00f6stergesi. Bu \u0131\u015f\u0131k, konum potansiyometresi u\u00e7lar\u0131nda a\u00e7\u0131k devre, k\u0131sa devre veya hasar oldu\u011funda yanar.<\/p><\/li><li><p><strong>L4: K\u0131rm\u0131z\u0131<\/strong> \u2013 S\u0131k\u0131\u015fma ar\u0131za g\u00f6stergesi. Mekanik bir s\u0131k\u0131\u015fma oldu\u011funda \u0131\u015f\u0131k yanar.<\/p><\/li><\/ul><p><strong>Ar\u0131za Te\u015fhis Mant\u0131\u011f\u0131:<\/strong><\/p><ul><li><p><strong>L2 A\u00e7\u0131k<\/strong>Giri\u015f sinyali 2,5mA&#039;den az veya 22mA&#039;den fazla ise, servo kontrol \u00fcnitesi giri\u015f sinyalinin ar\u0131zal\u0131 oldu\u011funu kabul eder. Giri\u015f sinyali terminalleri aras\u0131ndaki voltaj\u0131 \u00f6l\u00e7\u00fcn. 4~20mA&#039;lik bir giri\u015f sinyali i\u00e7in, giri\u015f sinyali terminalleri aras\u0131ndaki voltaj 0,88V ile 4,4V aras\u0131nda olmal\u0131d\u0131r. Giri\u015f sinyali 0,55V&#039;den (2,5mA&#039;ye kar\u015f\u0131l\u0131k gelir) az veya 4,84V&#039;den (22mA&#039;ye kar\u015f\u0131l\u0131k gelir) fazla ise, bu a\u00e7\u0131k devre, k\u0131sa devre, ka\u00e7ak veya kontrol sisteminden gelen yanl\u0131\u015f sinyali g\u00f6sterir. Terminaller aras\u0131ndaki voltaj normal ise ancak L2 hala a\u00e7\u0131k ise, servo kontrol \u00fcnitesinde bir ar\u0131za olabilir.<\/p><\/li><li><p><strong>L3 A\u00e7\u0131k<\/strong>: Konum alg\u0131lama devresinde bir ar\u0131za oldu\u011funu g\u00f6sterir. Potansiyometre u\u00e7lar\u0131n\u0131n a\u00e7\u0131k devre, k\u0131sa devre olup olmad\u0131\u011f\u0131n\u0131 veya potansiyometrenin kendisinin hasarl\u0131 olup olmad\u0131\u011f\u0131n\u0131 kontrol edin. Normalde, potansiyometre \u00fczerindeki voltaj yakla\u015f\u0131k 4V olmal\u0131 ve potansiyometrenin merkez \u00e7izgisi ile her iki ucu aras\u0131ndaki voltaj, potansiyometrenin a\u00e7\u0131s\u0131 de\u011fi\u015ftik\u00e7e de\u011fi\u015fmelidir. T\u00fcm kontroller normal ise ancak L3 hala yan\u0131yorsa, servo kontrol \u00fcnitesinde bir ar\u0131za olabilir.<\/p><\/li><li><p><strong>L4 A\u00e7\u0131k<\/strong>: \u00c7al\u0131\u015fma s\u0131ras\u0131nda mekanik bir ar\u0131za oldu\u011funu g\u00f6sterir. Motor kablolar\u0131n\u0131n gev\u015fek veya a\u00e7\u0131k olup olmad\u0131\u011f\u0131n\u0131 kontrol edin. Motorun kendisinin d\u00fczg\u00fcn \u00e7al\u0131\u015f\u0131p \u00e7al\u0131\u015fmad\u0131\u011f\u0131n\u0131 do\u011frulay\u0131n. Akt\u00fcat\u00f6r\u00fc her iki y\u00f6nde de \u00e7evirmek i\u00e7in el \u00e7ark\u0131n\u0131 kullan\u0131n ve herhangi bir s\u0131k\u0131\u015fma olup olmad\u0131\u011f\u0131n\u0131 kontrol edin. T\u00fcm kontroller normal ise ancak L4 hala yan\u0131yorsa, servo kontrol \u00fcnitesinde bir ar\u0131za olabilir.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-59d699f elementor-widget elementor-widget-heading\" data-id=\"59d699f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Sinyal \u00d6l\u00e7\u00fcm\u00fc<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-203fdc0 elementor-widget elementor-widget-text-editor\" data-id=\"203fdc0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li data-start=\"74\" data-end=\"325\">Akt\u00fcat\u00f6r\u00fcn g\u00fc\u00e7 kayna\u011f\u0131nda herhangi bir dalgalanma veya voltaj d\u00fc\u015f\u00fc\u015f\u00fc olup olmad\u0131\u011f\u0131n\u0131 kontrol etmek i\u00e7in 24V DC g\u00fc\u00e7 kayna\u011f\u0131 voltaj\u0131n\u0131 \u00f6l\u00e7\u00fcn. Negatif bas\u0131n\u00e7 durumunda, akt\u00fcat\u00f6r\u00fcn \u00e7\u0131k\u0131\u015f torku azalabilir ve bu da vanan\u0131n \u00e7al\u0131\u015ft\u0131r\u0131lmas\u0131n\u0131 engelleyebilir.<\/li><li data-start=\"74\" data-end=\"325\">Giri\u015f sinyali terminalleri (- ve +) aras\u0131ndaki voltaj\u0131 \u00f6l\u00e7\u00fcn.<\/li><li data-start=\"74\" data-end=\"325\">\u00c7\u0131k\u0131\u015f sinyali terminalleri (- ve +) aras\u0131ndaki voltaj\u0131 \u00f6l\u00e7\u00fcn.<\/li><li data-start=\"74\" data-end=\"325\">Harici bir sinyal uygulay\u0131n ve akt\u00fcat\u00f6r\u00fcn \u00e7al\u0131\u015fmas\u0131 s\u0131ras\u0131nda 24V DC g\u00fc\u00e7 kayna\u011f\u0131 voltaj\u0131n\u0131 \u00f6l\u00e7\u00fcn. (Bu, 24V DC g\u00fc\u00e7 kayna\u011f\u0131n\u0131n \u00e7al\u0131\u015fma kapasitesini ve kablolardaki voltaj d\u00fc\u015f\u00fc\u015f\u00fcn\u00fc do\u011frulamaya yard\u0131mc\u0131 olacakt\u0131r.)<\/li><\/ul><p>Proje sahas\u0131nda sorun giderme i\u015flemi s\u0131ras\u0131nda, ar\u0131zay\u0131 tespit etmek ve \u00e7\u00f6z\u00fcm bulmak i\u00e7in hemen teknik servis personelimizle ileti\u015fime ge\u00e7ebilirsiniz.<br data-start=\"853\" data-end=\"856\" \/>\u0130leti\u015fim numaras\u0131: 13026331611 (M\u00fchendis Chen)<\/p><ul><li style=\"list-style-type: none;\">\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Bu k\u0131lavuz, a\u015fa\u011f\u0131daki modellere sahip DCL Patlamaya Dayan\u0131kl\u0131 Seri \/ Hava Ko\u015fullar\u0131na Dayan\u0131kl\u0131 Seri \/ H\u0131zl\u0131 D\u00f6n\u00fc\u015fl\u00fc Seri mod\u00fclasyonlu akt\u00fcat\u00f6rler i\u00e7in ge\u00e7erlidir: Hava Ko\u015fullar\u0131na Dayan\u0131kl\u0131 Akt\u00fcat\u00f6r: DCL-02GEY, DCL-05GEY, DCL-10GEY, DCL-20GEY, DCL-40GEY, DCL-60GEY Patlamaya Dayan\u0131kl\u0131 Akt\u00fcat\u00f6r: DCL-Ex05GEY, DCL-Ex10GEY, DCL-Ex20GEY, DCL-Ex40GEY, DCL-Ex60GEY Bu k\u0131lavuzla ilgili daha fazla yard\u0131ma ihtiyac\u0131n\u0131z olursa l\u00fctfen bana bildirin! Elektrik Haznesini A\u00e7\u0131n [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[103],"tags":[53,36,66,57,52,48],"class_list":["post-6041","post","type-post","status-publish","format-standard","hentry","category-mr-actuator","tag-actuator","tag-dcl-gey","tag-explosion-proof-actuator","tag-general-actuator","tag-fast-move-actuator","tag-trouble-shooting-guide"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/tr_tr\/wp-json\/wp\/v2\/posts\/6041","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/tr_tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/tr_tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/tr_tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/tr_tr\/wp-json\/wp\/v2\/comments?post=6041"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/tr_tr\/wp-json\/wp\/v2\/posts\/6041\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/tr_tr\/wp-json\/wp\/v2\/media?parent=6041"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/tr_tr\/wp-json\/wp\/v2\/categories?post=6041"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/tr_tr\/wp-json\/wp\/v2\/tags?post=6041"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}