{"id":9257,"date":"2024-07-05T15:43:31","date_gmt":"2024-07-05T07:43:31","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=9257"},"modified":"2025-03-31T06:18:52","modified_gmt":"2025-03-31T06:18:52","slug":"dc-fb3","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/sv_se\/stod\/um-stalldon\/dc-fb3","title":{"rendered":"DC-FB3 anv\u00e4ndarmanual"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"9257\" class=\"elementor elementor-9257\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-342a362 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"342a362\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-aaa43ff\" data-id=\"aaa43ff\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-41c310b elementor-widget elementor-widget-text-editor\" data-id=\"41c310b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>DC-FB3-modulen, n\u00e4r den \u00e4r installerad i det elektriska DCL-st\u00e4lldonet, m\u00f6jligg\u00f6r styrning av ventilens position med Modbus-TCP\/IP. Installationen visas nedan:<\/p><figure style=\"width: 351px\" class=\"wp-caption alignnone\"><img fetchpriority=\"high\" decoding=\"async\" src=\"\/dam\/um\/images\/\/dc-fb3.webp\" alt=\"\" width=\"351\" height=\"406\" \/><figcaption class=\"wp-caption-text\">DC-FB3<\/figcaption><\/figure><h4>\u00a0<\/h4><figure style=\"width: 446px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"\" src=\"\/dam\/um\/images\/dcl-actuator-with-dc-fb3-scaled.webp\" alt=\"\" width=\"446\" height=\"559\" \/><figcaption class=\"wp-caption-text\">DC-FB3 installerad i DCL-st\u00e4lldonet<\/figcaption><\/figure><h2><strong>1. Styrning av DCL elektriskt st\u00e4lldon via Modbus-TCP\/IP med hj\u00e4lp av standardparametrar<\/strong><\/h2><p>DC-FB3 \u00e4r f\u00f6rkonfigurerad i klientl\u00e4ge. Med hj\u00e4lp av standardparametrarna f\u00f6r MAC, IP, Gateway, Server och Port kan du styra DCL:s elektriska st\u00e4lldon via Modbus-TCP\/IP. Standardparametrarna anges i den bl\u00e5 rutan i bilden nedan.<\/p><p>N\u00e4r du anv\u00e4nder standardparametrarna kan du hoppa \u00f6ver steg 2 och g\u00e5 direkt till steg 3 med hj\u00e4lp av Modbus-TCP\/IP f\u00f6r att styra det elektriska DCL-st\u00e4lldonet.<\/p><figure style=\"width: 500px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"\" src=\"\/dam\/um\/images\/dcl-actuator-with-dc-fb3-flag-scaled.webp\" alt=\"\" width=\"500\" height=\"627\" \/><figcaption class=\"wp-caption-text\">DCL Modbus TCP\/IP-st\u00e4lldon<\/figcaption><\/figure><h2><strong>2. \u00c4ndra TCP\/IP-n\u00e4tverksparametrar<\/strong><\/h2><h3><strong>2.1 Anslut DC-FB3 till datorn med DC-FB1 (USB till RS485)<\/strong><\/h3><figure style=\"width: 500px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"\/dam\/um\/images\/\/connect-dc-fb3-to-pc.webp\" alt=\"\" width=\"500\" height=\"374\" \/><figcaption class=\"wp-caption-text\">Anslutning av DCL-st\u00e4lldon med Modbus TCP\/IP till dator<\/figcaption><\/figure><p>Ledningarna f\u00f6r anslutning av DC-FB3 \u00e4r f\u00f6ljande:<\/p><ul><li><p><strong>R\u00f6d ruta 1<\/strong>Anslut till AC220V str\u00f6mf\u00f6rs\u00f6rjning.<\/p><\/li><li><p><strong>Gr\u00f6na rutan 4<\/strong>Anslut till RS485-gr\u00e4nssnittet (A\/B) p\u00e5 DC-FB1.<\/p><\/li><li><p><strong>DC-FB1 USB<\/strong>Anslut till datorn.<\/p><\/li><\/ul><p>F\u00f6r mer information, se anv\u00e4ndarmanualen f\u00f6r DC-FB1.<\/p><h5>\u00a0<\/h5><h3><strong>2.2 Anv\u00e4nd konfigurationsprogramvara p\u00e5 datorn f\u00f6r att st\u00e4lla in n\u00e4tverksparametrar<\/strong><\/h3><p><strong>Ladda ner konfigurationsprogramvara<\/strong>Installera n\u00f6dv\u00e4ndig konfigurationsprogramvara f\u00f6r att st\u00e4lla in n\u00e4tverksparametrarna.<\/p><p><strong>V\u00e4lj r\u00e4tt port<\/strong>\u00d6ppna konfigurationsprogramvaran, v\u00e4lj r\u00e4tt port och klicka p\u00e5 <strong>ANSLUTA<\/strong> f\u00f6r att ansluta till DC-FB3.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/um\/images\/\/dc-fb3-config3.webp\" width=\"681\" height=\"473\" \/><\/p><p>N\u00e4r den \u00e4r ansluten kommer konfigurationsprogramvaran automatiskt att l\u00e4sa parametrarna fr\u00e5n DC-FB3.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/um\/images\/\/dc-fb3-config2.webp\" width=\"676\" height=\"467\" \/><\/p><p><strong>\u00c4ndra n\u00e4tverksparametrar<\/strong>N\u00e4r du har \u00e4ndrat n\u00e4tverksparametrarna klickar du p\u00e5 <strong>SPARA<\/strong> f\u00f6r att lagra de uppdaterade parametrarna i DC-FB3.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/um\/images\/\/dc-fb3-config1.webp\" width=\"677\" height=\"472\" \/><\/p><h2><strong>3. Styr DCL-st\u00e4lldonet via Modbus-TCP\/IP<\/strong><\/h2><h3><strong>H\u00e5rdvaruanslutningar<\/strong><\/h3><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" src=\"\/dam\/um\/images\/dcl-actuator-with-dc-fb3-flag-scaled.webp\" width=\"500\" height=\"627\" \/><\/p><ul><li>Anslut AC220V str\u00f6mf\u00f6rs\u00f6rjning till terminalerna markerade med r\u00f6d ruta 1<\/li><li>S\u00e4tt i RJ45-kontakten i uttaget m\u00e4rkt med den gula rutan 2<\/li><\/ul><p>Nu kan du styra st\u00e4lldonet via Modbus-RTU-kommandon enligt <a href=\"\/sv_se\/stod\/um-stalldon\/um-sf-zc-modbus\/\">DCL-st\u00e4lldonets Modbus-applikationsmanual<\/a><\/p><p><a href=\"\/sv_se\/stod\/um-stalldon\/um-sf-zc-modbus\/\">L\u00e4r dig mer<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4060921 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"4060921\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-78394cd\" data-id=\"78394cd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4f45092 elementor-widget elementor-widget-text-editor\" data-id=\"4f45092\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"\/sv_se\/content\/dam\/nedladdningar\/app\/dlc_dc-fb3-v1.17.zip\/\" target=\"_blank\" rel=\"noopener\"><span style=\"text-decoration: underline;\">Ladda ner installationsprogramvara<\/span><\/a><\/p><p><a href=\"\/sv_se\/um\/dc-fb1\/\" target=\"_blank\" rel=\"noopener\"><span style=\"text-decoration: underline;\">Se bruksanvisningen f\u00f6r DC-FB1<\/span><\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>DC-FB3-modulen, n\u00e4r den \u00e4r installerad i det elektriska DCL-st\u00e4lldonet, m\u00f6jligg\u00f6r styrning av ventilens position med Modbus-TCP\/IP. Installationen visas nedan: 1. Styrning av DCL elektriskt st\u00e4lldon via Modbus-TCP\/IP med standardparametrar DC-FB3 \u00e4r f\u00f6rkonfigurerad i klientl\u00e4ge. Med hj\u00e4lp av standardparametrarna MAC, IP, Gateway, Server och Port kan du styra [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[9],"tags":[],"class_list":["post-9257","post","type-post","status-publish","format-standard","hentry","category-um-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/sv_se\/wp-json\/wp\/v2\/posts\/9257","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/sv_se\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/sv_se\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/sv_se\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/sv_se\/wp-json\/wp\/v2\/comments?post=9257"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/sv_se\/wp-json\/wp\/v2\/posts\/9257\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/sv_se\/wp-json\/wp\/v2\/media?parent=9257"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/sv_se\/wp-json\/wp\/v2\/categories?post=9257"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/sv_se\/wp-json\/wp\/v2\/tags?post=9257"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}