{"id":6537,"date":"2023-09-18T18:49:43","date_gmt":"2023-09-18T10:49:43","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6537"},"modified":"2025-03-28T10:33:47","modified_gmt":"2025-03-28T10:33:47","slug":"gb-t-3369-1-2008-iec-60381-1-1982","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/sl_sl\/podpora\/aktuator-ts\/gb-t-3369-1-2008-iec-60381-1-1982","title":{"rendered":"Standardi napetostnih signalov za elektri\u010dne aktuatorje \u2013 GB\/T 3369.2\u20142008\/IEC 60381-2:1978"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6537\" class=\"elementor elementor-6537\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4ad6800 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"4ad6800\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-448b26a\" data-id=\"448b26a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2d2988c elementor-widget elementor-widget-text-editor\" data-id=\"2d2988c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h4 class=\"\" data-start=\"243\" data-end=\"339\">Veljavni standardi za napetostne signale elektri\u010dnih aktuatorjev (1\u20135 V, 2\u201310 V, 0\u20135 V, 0\u201310 V):<\/h4><p class=\"\" data-start=\"340\" data-end=\"485\"><strong data-start=\"340\" data-end=\"457\">Analogni signali za sisteme za krmiljenje procesov \u2013 2. del: Enosmerni napetostni signali (GB\/T 3369.2\u20142008\/IEC 60381-2:1978)<\/strong><br data-start=\"457\" data-end=\"460\" \/><em data-start=\"460\" data-end=\"483\">IEC 60381-2-1978, IDT<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6d95a9b elementor-widget elementor-widget-image\" data-id=\"6d95a9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"678\" height=\"1028\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/09\/gbt3369-1-2008-IEC-60381-1-1982.png\" class=\"attachment-full size-full wp-image-6539\" alt=\"GB\/T 3369.1\u20142008\/IEC 60381-1:1982 - \u8fc7\u7a0b\u63a7\u5236\u7cfb\u7edf\u7528\u6a21\u62df\u4fe1\u53f7-\u7b2c1\u90e8\u5206\uff1a\u76f4\u6d41\u7535\u6d41\u4fe1\u53f7\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-314b810 elementor-widget elementor-widget-heading\" data-id=\"314b810\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Predgovor<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-303746d elementor-widget elementor-widget-text-editor\" data-id=\"303746d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"501\" data-end=\"618\">GB\/T 3369.2\u20142008\/IEC 60381-2:1978 \u2013 <em data-start=\"537\" data-end=\"616\">Analogni signali za sisteme za krmiljenje procesov \u2013 2. del: Signali enosmerne napetosti<\/em><\/p><p class=\"\" data-start=\"620\" data-end=\"681\">Standard GB\/T 3369 je sestavljen iz naslednjih dveh delov:<\/p><ul data-start=\"682\" data-end=\"764\"><li class=\"\" data-start=\"682\" data-end=\"725\"><p class=\"\" data-start=\"684\" data-end=\"725\"><strong data-start=\"684\" data-end=\"695\">1. del:<\/strong> Signali enosmernega toka (DC)<\/p><\/li><li class=\"\" data-start=\"726\" data-end=\"764\"><p class=\"\" data-start=\"728\" data-end=\"764\"><strong data-start=\"728\" data-end=\"739\">2. del:<\/strong> Neposredni napetostni signali<\/p><\/li><\/ul><p class=\"\" data-start=\"766\" data-end=\"817\">Ta dokument predstavlja <strong data-start=\"791\" data-end=\"801\">2. del<\/strong> iz GB\/T 3369.<\/p><p class=\"\" data-start=\"819\" data-end=\"957\">V celoti sprejema <strong data-start=\"835\" data-end=\"855\">IEC 60381-2:1978<\/strong>, <em data-start=\"857\" data-end=\"955\">Analogni signali za sisteme za krmiljenje procesov \u2013 2. del: Enosmerni napetostni signali (angle\u0161ka razli\u010dica).<\/em><\/p><p class=\"\" data-start=\"959\" data-end=\"1401\">Glede na <strong data-start=\"972\" data-end=\"989\">GB\/T 1.1\u20142000<\/strong> (<em data-start=\"991\" data-end=\"1066\">Vodnik za standardizacijsko delo \u2013 1. del: Standardna struktura in pravila pisanja<\/em>), so bile v standard IEC 60381-2:1978 narejene naslednje uredni\u0161ke spremembe:<br data-start=\"1137\" data-end=\"1140\" \/>a) Izraz <strong data-start=\"1152\" data-end=\"1171\">&quot;ta standard&quot;<\/strong> je bil spremenjen v <strong data-start=\"1187\" data-end=\"1203\">&quot;ta del.&quot;<\/strong><br data-start=\"1203\" data-end=\"1206\" \/>b) Predgovor standarda IEC 60381-2:1978 je bil odstranjen.<br data-start=\"1253\" data-end=\"1256\" \/>c) Vsako sklicevanje na <strong data-start=\"1276\" data-end=\"1291\">\u00bbIEC 60381\u00ab<\/strong> je bil zamenjan z <strong data-start=\"1310\" data-end=\"1326\">&quot;GB\/T 3369.&quot;<\/strong><br data-start=\"1326\" data-end=\"1329\" \/>d) Decimalna vejica <strong data-start=\"1350\" data-end=\"1357\">&#8220;,&#8221;<\/strong> je bila zamenjana z decimalno vejico <strong data-start=\"1392\" data-end=\"1399\">&#8220;.&#8221;<\/strong><\/p><p class=\"\" data-start=\"1403\" data-end=\"1511\">Ta del nadome\u0161\u010da <strong data-start=\"1422\" data-end=\"1440\">GB\/T 3370\u20141989<\/strong> (<em data-start=\"1442\" data-end=\"1507\">Analogni enosmerni napetostni signali za instrumente industrijske avtomatizacije<\/em>).<\/p><h3 data-start=\"1513\" data-end=\"1559\">\u00a0<\/h3><h3 data-start=\"1513\" data-end=\"1559\">Glavne spremembe v primerjavi z GB\/T 3370\u20141989:<\/h3><ul data-start=\"1560\" data-end=\"2575\"><li class=\"\" data-start=\"1560\" data-end=\"1756\"><p class=\"\" data-start=\"1562\" data-end=\"1756\">Standardno ime je bilo spremenjeno iz <strong data-start=\"1597\" data-end=\"1666\">&quot;Analogni enosmerni napetostni signali za instrumente industrijske avtomatizacije&quot;<\/strong> do <strong data-start=\"1670\" data-end=\"1754\">&quot;Analogni signali za sisteme za nadzor procesov \u2013 2. del: Signali enosmerne napetosti.&quot;<\/strong><\/p><\/li><li class=\"\" data-start=\"1757\" data-end=\"1824\"><p class=\"\" data-start=\"1759\" data-end=\"1824\">Izraz <strong data-start=\"1768\" data-end=\"1787\">&quot;ta standard&quot;<\/strong> je bil zamenjan z <strong data-start=\"1806\" data-end=\"1822\">&quot;ta del.&quot;<\/strong><\/p><\/li><li class=\"\" data-start=\"1825\" data-end=\"2119\"><p class=\"\" data-start=\"1827\" data-end=\"1854\"><strong data-start=\"1827\" data-end=\"1852\">Podro\u010dje uporabe:<\/strong><\/p><ul data-start=\"1857\" data-end=\"2119\"><li class=\"\" data-start=\"1857\" data-end=\"1967\"><p class=\"\" data-start=\"1859\" data-end=\"1967\"><strong data-start=\"1859\" data-end=\"1877\">GB\/T 3370\u20131989<\/strong> je temeljil na <strong data-start=\"1891\" data-end=\"1911\">IEC 60381-2:1979<\/strong> in se nana\u0161a na <strong data-start=\"1927\" data-end=\"1965\">instrumenti za industrijsko avtomatizacijo.<\/strong><\/p><\/li><li class=\"\" data-start=\"1970\" data-end=\"2119\"><p class=\"\" data-start=\"1972\" data-end=\"2119\"><strong data-start=\"1972\" data-end=\"1992\">GB\/T 3369.2\u20142008<\/strong> je <strong data-start=\"1999\" data-end=\"2022\">enakovredna posvojitev<\/strong> od <strong data-start=\"2026\" data-end=\"2046\">IEC 60381-2:1979<\/strong> in velja za <strong data-start=\"2062\" data-end=\"2117\">sistemi za merjenje in nadzor industrijskih procesov.<\/strong><\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"2120\" data-end=\"2205\"><p class=\"\" data-start=\"2122\" data-end=\"2205\">Izraz <strong data-start=\"2131\" data-end=\"2170\">&quot;Instrumenti za industrijsko avtomatizacijo&quot;<\/strong> je bil spremenjen v <strong data-start=\"2186\" data-end=\"2203\">&quot;komponente&quot;.<\/strong><\/p><\/li><li class=\"\" data-start=\"2206\" data-end=\"2501\"><p class=\"\" data-start=\"2208\" data-end=\"2328\">The <strong data-start=\"2212\" data-end=\"2232\">\u00bbVsebina valovanja\u00ab<\/strong> in <strong data-start=\"2237\" data-end=\"2262\">&quot;Izhodna AC komponenta&quot;<\/strong> definicije so bile odstranjene, dodane pa so bile nove definicije za:<\/p><ul data-start=\"2331\" data-end=\"2501\"><li class=\"\" data-start=\"2331\" data-end=\"2392\"><p class=\"\" data-start=\"2333\" data-end=\"2392\"><strong data-start=\"2333\" data-end=\"2390\">&quot;Izmerjena vrednost analognega enosmernega napetostnega signala&quot;<\/strong><\/p><\/li><li class=\"\" data-start=\"2395\" data-end=\"2419\"><p class=\"\" data-start=\"2397\" data-end=\"2419\"><strong data-start=\"2397\" data-end=\"2417\">&quot;Impedanca obremenitve&quot;<\/strong><\/p><\/li><li class=\"\" data-start=\"2422\" data-end=\"2446\"><p class=\"\" data-start=\"2424\" data-end=\"2446\"><strong data-start=\"2424\" data-end=\"2444\">\u00bbVsebina Ripple\u00ab<\/strong><\/p><\/li><li class=\"\" data-start=\"2449\" data-end=\"2472\"><p class=\"\" data-start=\"2451\" data-end=\"2472\"><strong data-start=\"2451\" data-end=\"2470\">&quot;Skupni signal&quot;<\/strong><\/p><\/li><li class=\"\" data-start=\"2475\" data-end=\"2501\"><p class=\"\" data-start=\"2477\" data-end=\"2501\"><strong data-start=\"2477\" data-end=\"2499\">&quot;Izolacija signala&quot;<\/strong><\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"2502\" data-end=\"2575\"><p class=\"\" data-start=\"2504\" data-end=\"2575\">Tabela 1 zdaj vklju\u010duje razpone signalov <strong data-start=\"2539\" data-end=\"2552\">0 do +10 V<\/strong> in <strong data-start=\"2557\" data-end=\"2573\">-10 do +10 V.<\/strong><\/p><\/li><\/ul><h3 data-start=\"2577\" data-end=\"2609\">\u00a0<\/h3><h3 data-start=\"2577\" data-end=\"2609\">Odgovorne organizacije:<\/h3><ul data-start=\"2610\" data-end=\"3176\"><li class=\"\" data-start=\"2610\" data-end=\"2666\"><p class=\"\" data-start=\"2612\" data-end=\"2666\"><strong data-start=\"2612\" data-end=\"2628\">Predlagatelj:<\/strong> Kitajska zveza strojne industrije<\/p><\/li><li class=\"\" data-start=\"2667\" data-end=\"2799\"><p class=\"\" data-start=\"2669\" data-end=\"2799\"><strong data-start=\"2669\" data-end=\"2684\">Upravlja:<\/strong> Nacionalni tehni\u010dni odbor za standardizacijo meritev in nadzora industrijskih procesov (drugi pododbor)<\/p><\/li><li class=\"\" data-start=\"2800\" data-end=\"2882\"><p class=\"\" data-start=\"2802\" data-end=\"2882\"><strong data-start=\"2802\" data-end=\"2828\">Institucije za pripravo osnutkov:<\/strong> Univerza Jugozahod, Kitajska Skupina za instrumente Silian<\/p><\/li><li class=\"\" data-start=\"2883\" data-end=\"3052\"><p class=\"\" data-start=\"2885\" data-end=\"2918\"><strong data-start=\"2885\" data-end=\"2916\">Sodelujo\u010de institucije:<\/strong><\/p><ul data-start=\"2921\" data-end=\"3052\"><li class=\"\" data-start=\"2921\" data-end=\"2992\"><p class=\"\" data-start=\"2923\" data-end=\"2992\">Kitajski in\u0161titut za instrumente in ekonomske raziskave strojne industrije<\/p><\/li><li class=\"\" data-start=\"2995\" data-end=\"3052\"><p class=\"\" data-start=\"2997\" data-end=\"3052\">Pekin\u0161ki in\u0161titut za avtomatizacijo strojne industrije<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"3053\" data-end=\"3125\"><p class=\"\" data-start=\"3055\" data-end=\"3125\"><strong data-start=\"3055\" data-end=\"3083\">Glavno osebje za pripravo osnutkov:<\/strong> Liu Feng, Pan Dongbo, Zhang Yu, Liu Jin<\/p><\/li><li class=\"\" data-start=\"3126\" data-end=\"3176\"><p class=\"\" data-start=\"3128\" data-end=\"3176\"><strong data-start=\"3128\" data-end=\"3145\">Sodelavci:<\/strong> Feng Xiaosheng, Xie Bingbing<\/p><\/li><\/ul><p class=\"\" data-start=\"3178\" data-end=\"3218\">Ta del nadome\u0161\u010da prej\u0161nje standarde:<\/p><ul data-start=\"3219\" data-end=\"3262\"><li class=\"\" data-start=\"3219\" data-end=\"3239\"><p class=\"\" data-start=\"3221\" data-end=\"3239\"><strong data-start=\"3221\" data-end=\"3237\">GB 3370\u20141982<\/strong><\/p><\/li><li class=\"\" data-start=\"3240\" data-end=\"3262\"><p class=\"\" data-start=\"3242\" data-end=\"3262\"><strong data-start=\"3242\" data-end=\"3260\">GB\/T 3370\u20141989<\/strong><\/p><\/li><\/ul><h2 data-start=\"3269\" data-end=\"3355\">\u00a0<\/h2><h2 data-start=\"3269\" data-end=\"3355\"><strong data-start=\"3272\" data-end=\"3353\">Analogni signali za sisteme za krmiljenje procesov \u2013 2. del: Signali enosmerne napetosti<\/strong><\/h2><h3 data-start=\"3357\" data-end=\"3375\">\u00a0<\/h3><h3 data-start=\"3357\" data-end=\"3375\"><strong data-start=\"3361\" data-end=\"3373\">1. Podro\u010dje uporabe<\/strong><\/h3><p class=\"\" data-start=\"3376\" data-end=\"3553\">Ta del velja za <strong data-start=\"3397\" data-end=\"3432\">analogni enosmerni napetostni signali<\/strong> uporablja se za prenos informacij med sistemskimi komponentami v <strong data-start=\"3496\" data-end=\"3551\">sistemi za merjenje in nadzor industrijskih procesov.<\/strong><\/p><p class=\"\" data-start=\"3555\" data-end=\"3733\">Za razliko od <strong data-start=\"3566\" data-end=\"3601\">analogni enosmerni signali<\/strong> dolo\u010deno v <strong data-start=\"3615\" data-end=\"3635\">GB\/T 3369.1-2008<\/strong>, <strong data-start=\"3637\" data-end=\"3672\">analogni enosmerni napetostni signali<\/strong> bi moral <strong data-start=\"3680\" data-end=\"3687\">ne<\/strong> se uporablja za <strong data-start=\"3700\" data-end=\"3731\">prenos na dolge razdalje.<\/strong><\/p><p class=\"\" data-start=\"3735\" data-end=\"3821\">Ta del <strong data-start=\"3745\" data-end=\"3757\">ne<\/strong> velja za signale, ki se uporabljajo v celoti <strong data-start=\"3789\" data-end=\"3819\">znotraj ene same komponente.<\/strong><\/p><h3 data-start=\"3828\" data-end=\"3862\">\u00a0<\/h3><h3 class=\"\" data-start=\"3828\" data-end=\"3862\"><strong data-start=\"3832\" data-end=\"3860\">2. Izrazi in definicije<\/strong><\/h3><h4 class=\"\" data-start=\"3864\" data-end=\"3943\"><strong data-start=\"3869\" data-end=\"3941\">2.1 Komponente sistemov za merjenje in krmiljenje industrijskih procesov<\/strong><\/h4><p class=\"\" data-start=\"3944\" data-end=\"4123\">Funkcionalne enote in integrirane kombinirane naprave, ki se uporabljajo za <strong data-start=\"4004\" data-end=\"4121\">pretvarjati, prena\u0161ati ali obdelovati izmerjene vrednosti, regulacijske koli\u010dine, regulirane spremenljivke in referen\u010dne spremenljivke.<\/strong><\/p><h4 class=\"\" data-start=\"4125\" data-end=\"4170\"><strong data-start=\"4130\" data-end=\"4168\">2.2 Analogni enosmerni napetostni signal<\/strong><\/h4><p class=\"\" data-start=\"4171\" data-end=\"4316\">A <strong data-start=\"4173\" data-end=\"4194\">enosmerni napetostni signal<\/strong> ki se neprekinjeno spreminja glede na eno ali ve\u010d fizikalnih veli\u010din, uporabljenih za <strong data-start=\"4271\" data-end=\"4314\">prenos ali obdelava informacij.<\/strong><\/p><h4 class=\"\" data-start=\"4318\" data-end=\"4384\"><strong data-start=\"4323\" data-end=\"4382\">2.3 Izmerjena vrednost analognega enosmernega napetostnega signala<\/strong><\/h4><p class=\"\" data-start=\"4385\" data-end=\"4476\">The <strong data-start=\"4389\" data-end=\"4406\">povpre\u010dna vrednost<\/strong> analognega enosmernega napetostnega signala <strong data-start=\"4444\" data-end=\"4474\">v dolo\u010denem obdobju.<\/strong><\/p><h4 class=\"\" data-start=\"4478\" data-end=\"4504\"><strong data-start=\"4483\" data-end=\"4502\">2.4 Spodnja meja<\/strong><\/h4><p class=\"\" data-start=\"4505\" data-end=\"4575\">The <strong data-start=\"4509\" data-end=\"4520\">minimalno<\/strong> vrednost napetosti analognega enosmernega napetostnega signala.<\/p><h4 class=\"\" data-start=\"4577\" data-end=\"4603\"><strong data-start=\"4582\" data-end=\"4601\">2.5 Zgornja meja<\/strong><\/h4><p class=\"\" data-start=\"4604\" data-end=\"4674\">The <strong data-start=\"4608\" data-end=\"4619\">najve\u010d<\/strong> vrednost napetosti analognega enosmernega napetostnega signala.<\/p><h4 class=\"\" data-start=\"4676\" data-end=\"4733\"><strong data-start=\"4681\" data-end=\"4731\">2.6 Obmo\u010dje analognega enosmernega napetostnega signala<\/strong><\/h4><p class=\"\" data-start=\"4734\" data-end=\"4819\">Obseg, ki ga dolo\u010da <strong data-start=\"4759\" data-end=\"4774\">spodnja meja<\/strong> in <strong data-start=\"4779\" data-end=\"4794\">zgornja meja<\/strong> napetosti signala.<\/p><h4 class=\"\" data-start=\"4821\" data-end=\"4850\"><strong data-start=\"4826\" data-end=\"4848\">2.7 Impedanca obremenitve<\/strong><\/h4><p class=\"\" data-start=\"4851\" data-end=\"4904\">Skupna impedanca vseh <strong data-start=\"4878\" data-end=\"4902\">priklju\u010deni sprejemniki.<\/strong><\/p><h4 class=\"\" data-start=\"4906\" data-end=\"4935\"><strong data-start=\"4911\" data-end=\"4933\">2.8 Vsebina Ripple<\/strong><\/h4><p class=\"\" data-start=\"4936\" data-end=\"5059\">Razmerje med <strong data-start=\"4953\" data-end=\"4995\">medvr\u0161na vrednost izmeni\u010dne komponente<\/strong> do <strong data-start=\"5003\" data-end=\"5018\">zgornja meja<\/strong> analognega enosmernega napetostnega signala.<\/p><h4 class=\"\" data-start=\"5061\" data-end=\"5089\"><strong data-start=\"5066\" data-end=\"5087\">2.9 Skupni signal<\/strong><\/h4><p class=\"\" data-start=\"5090\" data-end=\"5192\">Skupna elektri\u010dna povezava, ki si jo deli ve\u010d signalnih vezij, ki so lahko ozemljena ali pa tudi ne.<\/p><h4 class=\"\" data-start=\"5194\" data-end=\"5226\"><strong data-start=\"5199\" data-end=\"5224\">2.10 Izolacija signala<\/strong><\/h4><p class=\"\" data-start=\"5227\" data-end=\"5339\">Odsotnost <strong data-start=\"5242\" data-end=\"5268\">elektri\u010dni priklju\u010dki<\/strong> med <strong data-start=\"5281\" data-end=\"5299\">signalno vezje<\/strong> in druga vezja ali <strong data-start=\"5326\" data-end=\"5337\">tla.<\/strong><\/p><h3 data-start=\"5346\" data-end=\"5381\">\u00a0<\/h3><h3 class=\"\" data-start=\"5346\" data-end=\"5381\"><strong data-start=\"5350\" data-end=\"5379\">3. Tehni\u010dne zahteve<\/strong><\/h3><h4 class=\"\" data-start=\"5383\" data-end=\"5438\"><strong data-start=\"5388\" data-end=\"5436\">3.1 Obmo\u010dje analognih enosmernih napetostnih signalov<\/strong><\/h4><p class=\"\" data-start=\"5439\" data-end=\"5493\">Tabela 1 prikazuje standardna obmo\u010dja napetostnih signalov.<\/p><div class=\"overflow-x-auto contain-inline-size\"><table data-start=\"5495\" data-end=\"5720\"><thead data-start=\"5495\" data-end=\"5534\"><tr data-start=\"5495\" data-end=\"5534\"><th data-start=\"5495\" data-end=\"5513\">Spodnja meja (V)<\/th><th data-start=\"5513\" data-end=\"5534\">Zgornja meja (V)<\/th><\/tr><\/thead><tbody data-start=\"5573\" data-end=\"5720\"><tr data-start=\"5573\" data-end=\"5609\"><td>+1<\/td><td>+5<\/td><\/tr><tr data-start=\"5610\" data-end=\"5646\"><td>0<\/td><td>+5<\/td><\/tr><tr data-start=\"5647\" data-end=\"5683\"><td>0<\/td><td>+10<\/td><\/tr><tr data-start=\"5684\" data-end=\"5720\"><td>-10<\/td><td>+10<\/td><\/tr><\/tbody><\/table><\/div><p class=\"\" data-start=\"5722\" data-end=\"5734\"><strong data-start=\"5722\" data-end=\"5732\">Opombe:<\/strong><\/p><ul data-start=\"5735\" data-end=\"5938\"><li class=\"\" data-start=\"5735\" data-end=\"5845\"><p class=\"\" data-start=\"5737\" data-end=\"5845\">Napetostni signali <strong data-start=\"5753\" data-end=\"5771\">je mogo\u010de izpeljati<\/strong> iz analognih enosmernih signalov, dolo\u010denih v <strong data-start=\"5822\" data-end=\"5843\">GB\/T 3369.1\u20142008.<\/strong><\/p><\/li><li class=\"\" data-start=\"5846\" data-end=\"5938\"><p class=\"\" data-start=\"5848\" data-end=\"5938\">Napetostni signali <strong data-start=\"5864\" data-end=\"5871\">lahko<\/strong> predstavljajo fizikalne koli\u010dine z uporabo <strong data-start=\"5908\" data-end=\"5936\">bipolarne zna\u010dilnosti.<\/strong><\/p><\/li><\/ul><h4 class=\"\" data-start=\"5945\" data-end=\"5974\"><strong data-start=\"5950\" data-end=\"5972\">3.2 Vsebina Ripple<\/strong><\/h4><p class=\"\" data-start=\"5975\" data-end=\"6057\">Pri uporabi <strong data-start=\"5986\" data-end=\"6019\">enosmerni napajalniki brez valovanja<\/strong>, je treba navesti naslednje:<\/p><ul data-start=\"6058\" data-end=\"6274\"><li class=\"\" data-start=\"6058\" data-end=\"6124\"><p class=\"\" data-start=\"6060\" data-end=\"6124\"><strong data-start=\"6060\" data-end=\"6092\">Vsebina in frekvenca valovanja<\/strong> znotraj sistemskih komponent.<\/p><\/li><li class=\"\" data-start=\"6125\" data-end=\"6192\"><p class=\"\" data-start=\"6127\" data-end=\"6192\"><strong data-start=\"6127\" data-end=\"6150\">Hrup in frekvenca<\/strong> ustvarjene znotraj sistemskih komponent.<\/p><\/li><li class=\"\" data-start=\"6193\" data-end=\"6274\"><p class=\"\" data-start=\"6195\" data-end=\"6274\">Vsebina valovanja, ki jo povzro\u010da <strong data-start=\"6220\" data-end=\"6246\">Valovanje enosmernega napajanja<\/strong> je treba tudi navesti.<\/p><\/li><\/ul><h4 class=\"\" data-start=\"6281\" data-end=\"6314\"><strong data-start=\"6286\" data-end=\"6312\">3.3 Skupna linija signala<\/strong><\/h4><ul data-start=\"6315\" data-end=\"6705\"><li class=\"\" data-start=\"6315\" data-end=\"6511\"><p class=\"\" data-start=\"6317\" data-end=\"6511\">Za <strong data-start=\"6321\" data-end=\"6341\">unipolarni signali<\/strong>, ta <strong data-start=\"6347\" data-end=\"6368\">negativni pol<\/strong> slu\u017ei kot skupna signalna linija. \u010ce je priklju\u010den na <strong data-start=\"6421\" data-end=\"6440\">Napajalnik z enosmernim tokom<\/strong>, bi se moral povezati z <strong data-start=\"6467\" data-end=\"6488\">negativni pol<\/strong> napajalnika.<\/p><\/li><li class=\"\" data-start=\"6512\" data-end=\"6705\"><p class=\"\" data-start=\"6514\" data-end=\"6705\">Za <strong data-start=\"6518\" data-end=\"6537\">bipolarni signali<\/strong>, ta <strong data-start=\"6543\" data-end=\"6563\">nevtralni terminal<\/strong> slu\u017ei kot skupna signalna linija. \u010ce je priklju\u010den na <strong data-start=\"6616\" data-end=\"6635\">Napajalnik z enosmernim tokom<\/strong>, bi se moral povezati z <strong data-start=\"6662\" data-end=\"6682\">nevtralni terminal<\/strong> napajalnika.<\/p><\/li><\/ul><h4 class=\"\" data-start=\"6712\" data-end=\"6736\"><strong data-start=\"6717\" data-end=\"6734\">3.4 Ozemljitev<\/strong><\/h4><ul data-start=\"6737\" data-end=\"7033\"><li class=\"\" data-start=\"6737\" data-end=\"6888\"><p class=\"\" data-start=\"6739\" data-end=\"6888\">Za <strong data-start=\"6743\" data-end=\"6763\">unipolarni signali<\/strong>, \u010de je komponenta <strong data-start=\"6785\" data-end=\"6797\">prizemljen<\/strong>, ta <strong data-start=\"6803\" data-end=\"6824\">negativni pol<\/strong> signalnega in\/ali enosmernega napajanja mora biti tudi ozemljen.<\/p><\/li><li class=\"\" data-start=\"6889\" data-end=\"7033\"><p class=\"\" data-start=\"6891\" data-end=\"7033\">Za <strong data-start=\"6895\" data-end=\"6914\">bipolarni signali<\/strong>, \u010de je komponenta <strong data-start=\"6936\" data-end=\"6948\">prizemljen<\/strong>, ta <strong data-start=\"6954\" data-end=\"6974\">nevtralni terminal<\/strong> signala in\/ali enosmernega napajanja mora biti ozemljen.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Veljavni standardi za napetostne signale elektri\u010dnih aktuatorjev (1\u20135 V, 2\u201310 V, 0\u20135 V, 0\u201310 V): Analogni signali za sisteme za krmiljenje procesov \u2013 2. del: Enosmerni napetostni signali (GB\/T 3369.2\u20142008\/IEC 60381-2:1978)IEC 60381-2-1978, IDT Predgovor GB\/T 3369.2\u20142008\/IEC 60381-2:1978 \u2013 Analogni signali za sisteme za krmiljenje procesov \u2013 2. del: Enosmerni napetostni signali Standard GB\/T 3369 je sestavljen iz naslednjih dveh delov: [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[3],"tags":[49],"class_list":["post-6537","post","type-post","status-publish","format-standard","hentry","category-ts-actuator","tag-input-signal"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/sl_sl\/wp-json\/wp\/v2\/posts\/6537","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/sl_sl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/sl_sl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/sl_sl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/sl_sl\/wp-json\/wp\/v2\/comments?post=6537"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/sl_sl\/wp-json\/wp\/v2\/posts\/6537\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/sl_sl\/wp-json\/wp\/v2\/media?parent=6537"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/sl_sl\/wp-json\/wp\/v2\/categories?post=6537"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/sl_sl\/wp-json\/wp\/v2\/tags?post=6537"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}