{"id":9257,"date":"2024-07-05T15:43:31","date_gmt":"2024-07-05T07:43:31","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=9257"},"modified":"2025-03-31T06:18:52","modified_gmt":"2025-03-31T06:18:52","slug":"dc-fb3","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/pt_pt\/apoio\/um-atuador\/dc-fb3","title":{"rendered":"Manual do utilizador DC-FB3"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"9257\" class=\"elementor elementor-9257\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-342a362 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"342a362\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-aaa43ff\" data-id=\"aaa43ff\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-41c310b elementor-widget elementor-widget-text-editor\" data-id=\"41c310b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>O m\u00f3dulo DC-FB3, quando instalado no atuador el\u00e9trico DCL, permite controlar a posi\u00e7\u00e3o da v\u00e1lvula utilizando Modbus-TCP\/IP. A instala\u00e7\u00e3o \u00e9 mostrada abaixo:<\/p><figure style=\"width: 351px\" class=\"wp-caption alignnone\"><img fetchpriority=\"high\" decoding=\"async\" src=\"\/dam\/um\/images\/\/dc-fb3.webp\" alt=\"\" width=\"351\" height=\"406\" \/><figcaption class=\"wp-caption-text\">DC-FB3<\/figcaption><\/figure><h4>\u00a0<\/h4><figure style=\"width: 446px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"\" src=\"\/dam\/um\/images\/dcl-actuator-with-dc-fb3-scaled.webp\" alt=\"\" width=\"446\" height=\"559\" \/><figcaption class=\"wp-caption-text\">DC-FB3 Instalado no Atuador DCL<\/figcaption><\/figure><h2><strong>1. Controlar o Atuador El\u00e9trico DCL via Modbus-TCP\/IP Utilizando Par\u00e2metros Predefinidos<\/strong><\/h2><p>O DC-FB3 est\u00e1 pr\u00e9-configurado no modo Cliente. Utilizando os par\u00e2metros predefinidos de MAC, IP, Gateway, Servidor e Porta, \u00e9 poss\u00edvel controlar o atuador el\u00e9trico DCL atrav\u00e9s de Modbus-TCP\/IP. Os par\u00e2metros predefinidos est\u00e3o indicados dentro da caixa azul na imagem abaixo.<\/p><p>Quando utilizar os par\u00e2metros predefinidos, pode saltar o passo 2 e avan\u00e7ar diretamente para o passo 3, utilizando o Modbus-TCP\/IP para controlar o atuador el\u00e9trico DCL.<\/p><figure style=\"width: 500px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"\" src=\"\/dam\/um\/images\/dcl-actuator-with-dc-fb3-flag-scaled.webp\" alt=\"\" width=\"500\" height=\"627\" \/><figcaption class=\"wp-caption-text\">Atuador DCL Modbus TCP\/IP<\/figcaption><\/figure><h2><strong>2. Alterar os par\u00e2metros de rede TCP\/IP<\/strong><\/h2><h3><strong>2.1 Ligar o DC-FB3 ao PC utilizando o DC-FB1 (USB para RS485)<\/strong><\/h3><figure style=\"width: 500px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"\/dam\/um\/images\/\/connect-dc-fb3-to-pc.webp\" alt=\"\" width=\"500\" height=\"374\" \/><figcaption class=\"wp-caption-text\">Ligar o Atuador DCL com Modbus TCP\/IP ao Computador<\/figcaption><\/figure><p>A cablagem para ligar o DC-FB3 \u00e9 a seguinte:<\/p><ul><li><p><strong>Caixa vermelha 1<\/strong>: Ligar \u00e0 fonte de alimenta\u00e7\u00e3o AC220V.<\/p><\/li><li><p><strong>Caixa Verde 4<\/strong>: Ligar \u00e0 interface RS485 (A\/B) do DC-FB1.<\/p><\/li><li><p><strong>DC-FB1 USB<\/strong>: Ligar ao PC.<\/p><\/li><\/ul><p>Para mais informa\u00e7\u00f5es, consulte o manual do utilizador do DC-FB1.<\/p><h5>\u00a0<\/h5><h3><strong>2.2 Utilizar o software de configura\u00e7\u00e3o no PC para definir os par\u00e2metros de rede<\/strong><\/h3><p><strong>Descarregar o software de configura\u00e7\u00e3o<\/strong>: Instalar o software de configura\u00e7\u00e3o necess\u00e1rio para definir os par\u00e2metros da rede.<\/p><p><strong>Selecionar a porta correta<\/strong>: Abrir o software de configura\u00e7\u00e3o, escolher a porta correta e clicar em <strong>CONECTAR<\/strong> para ligar ao DC-FB3.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/um\/images\/\/dc-fb3-config3.webp\" width=\"681\" height=\"473\" \/><\/p><p>Uma vez ligado, o software de configura\u00e7\u00e3o ler\u00e1 automaticamente os par\u00e2metros do DC-FB3.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/um\/images\/\/dc-fb3-config2.webp\" width=\"676\" height=\"467\" \/><\/p><p><strong>Alterar os par\u00e2metros da rede<\/strong>: Depois de modificar os par\u00e2metros de rede, clique em <strong>SALVAR<\/strong> para guardar os par\u00e2metros actualizados no DC-FB3.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/um\/images\/\/dc-fb3-config1.webp\" width=\"677\" height=\"472\" \/><\/p><h2><strong>3. Controlo do Atuador DCL atrav\u00e9s de Modbus-TCP\/IP<\/strong><\/h2><h3><strong>Liga\u00e7\u00f5es de hardware<\/strong><\/h3><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" src=\"\/dam\/um\/images\/dcl-actuator-with-dc-fb3-flag-scaled.webp\" width=\"500\" height=\"627\" \/><\/p><ul><li>Ligar a fonte de alimenta\u00e7\u00e3o AC220V aos terminais marcados com a caixa vermelha 1<\/li><li>Introduzir a ficha RJ45 na tomada marcada com a caixa amarela 2<\/li><\/ul><p>Agora \u00e9 poss\u00edvel controlar o atuador atrav\u00e9s de comandos modbus-RTU seguindo o <a href=\"\/pt_pt\/apoio\/um-atuador\/um-sf-zc-modbus\/\">Manual de Aplica\u00e7\u00e3o Modbus do Atuador DCL<\/a><\/p><p><a href=\"\/pt_pt\/apoio\/um-atuador\/um-sf-zc-modbus\/\">Saiba mais<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4060921 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"4060921\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-78394cd\" data-id=\"78394cd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4f45092 elementor-widget elementor-widget-text-editor\" data-id=\"4f45092\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"\/pt_pt\/content\/dam\/downloads\/app\/DLC_DC-FB3-v1.17.zip\/\" target=\"_blank\" rel=\"noopener\"><span style=\"text-decoration: underline;\">Descarregar o software de configura\u00e7\u00e3o<\/span><\/a><\/p><p><a href=\"\/pt_pt\/um\/dc-fb1\/\" target=\"_blank\" rel=\"noopener\"><span style=\"text-decoration: underline;\">Ver instru\u00e7\u00f5es de utiliza\u00e7\u00e3o do DC-FB1<\/span><\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>O m\u00f3dulo DC-FB3, quando instalado no atuador el\u00e9trico DCL, permite o controle da posi\u00e7\u00e3o da v\u00e1lvula usando Modbus-TCP\/IP. A instala\u00e7\u00e3o \u00e9 mostrada abaixo: 1. Controlando o atuador el\u00e9trico DCL via Modbus-TCP\/IP usando os par\u00e2metros padr\u00e3o O DC-FB3 vem pr\u00e9-configurado no modo Cliente. Usando os par\u00e2metros padr\u00e3o de MAC, IP, Gateway, Servidor e Porta, voc\u00ea pode controlar o atuador el\u00e9trico DCL via Modbus-TCP\/IP usando os par\u00e2metros padr\u00e3o.<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[9],"tags":[],"class_list":["post-9257","post","type-post","status-publish","format-standard","hentry","category-um-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/posts\/9257","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/comments?post=9257"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/posts\/9257\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/media?parent=9257"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/categories?post=9257"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/tags?post=9257"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}