{"id":6537,"date":"2023-09-18T18:49:43","date_gmt":"2023-09-18T10:49:43","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6537"},"modified":"2025-03-28T10:33:47","modified_gmt":"2025-03-28T10:33:47","slug":"gb-t-3369-1-2008-iec-60381-1-1982","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/pt_pt\/apoio\/atuador-ts\/gb-t-3369-1-2008-iec-60381-1-1982","title":{"rendered":"Normas de sinal de tens\u00e3o para atuadores el\u00e9tricos \u2013 GB\/T 3369.2\u20142008\/IEC 60381-2:1978"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6537\" class=\"elementor elementor-6537\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4ad6800 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"4ad6800\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-448b26a\" data-id=\"448b26a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2d2988c elementor-widget elementor-widget-text-editor\" data-id=\"2d2988c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h4 class=\"\" data-start=\"243\" data-end=\"339\">Normas aplic\u00e1veis para sinais de tens\u00e3o de atuadores el\u00e9tricos (1-5V, 2-10V, 0-5V, 0-10V):<\/h4><p class=\"\" data-start=\"340\" data-end=\"485\"><strong data-start=\"340\" data-end=\"457\">Sinais anal\u00f3gicos para sistemas de controle de processos \u2013 Parte 2: Sinais de tens\u00e3o direta (GB\/T 3369.2\u20142008\/IEC 60381-2:1978)<\/strong><br data-start=\"457\" data-end=\"460\" \/><em data-start=\"460\" data-end=\"483\">IEC 60381-2-1978, IDT<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6d95a9b elementor-widget elementor-widget-image\" data-id=\"6d95a9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"678\" height=\"1028\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/09\/gbt3369-1-2008-IEC-60381-1-1982.png\" class=\"attachment-full size-full wp-image-6539\" alt=\"GB\/T 3369.1\u20142008\/IEC 60381-1:1982 - \u8fc7\u7a0b\u63a7\u5236\u7cfb\u7edf\u7528\u6a21\u62df\u4fe1\u53f7-\u7b2c1\u90e8\u5206\uff1a\u76f4\u6d41\u7535\u6d41\u4fe1\u53f7\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-314b810 elementor-widget elementor-widget-heading\" data-id=\"314b810\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pref\u00e1cio<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-303746d elementor-widget elementor-widget-text-editor\" data-id=\"303746d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"501\" data-end=\"618\">GB\/T 3369.2\u20142008\/IEC 60381-2:1978 \u2013 <em data-start=\"537\" data-end=\"616\">Sinais anal\u00f3gicos para sistemas de controle de processos \u2013 Parte 2: Sinais de tens\u00e3o direta<\/em><\/p><p class=\"\" data-start=\"620\" data-end=\"681\">A norma GB\/T 3369 consiste nas seguintes duas partes:<\/p><ul data-start=\"682\" data-end=\"764\"><li class=\"\" data-start=\"682\" data-end=\"725\"><p class=\"\" data-start=\"684\" data-end=\"725\"><strong data-start=\"684\" data-end=\"695\">Parte 1:<\/strong> Sinais de corrente cont\u00ednua (CC)<\/p><\/li><li class=\"\" data-start=\"726\" data-end=\"764\"><p class=\"\" data-start=\"728\" data-end=\"764\"><strong data-start=\"728\" data-end=\"739\">Parte 2:<\/strong> Sinais de tens\u00e3o direta<\/p><\/li><\/ul><p class=\"\" data-start=\"766\" data-end=\"817\">Este documento representa <strong data-start=\"791\" data-end=\"801\">Parte 2<\/strong> de GB\/T 3369.<\/p><p class=\"\" data-start=\"819\" data-end=\"957\">Adota integralmente <strong data-start=\"835\" data-end=\"855\">IEC 60381-2:1978<\/strong>, <em data-start=\"857\" data-end=\"955\">Sinais anal\u00f3gicos para sistemas de controle de processos \u2013 Parte 2: Sinais de tens\u00e3o direta (vers\u00e3o em ingl\u00eas).<\/em><\/p><p class=\"\" data-start=\"959\" data-end=\"1401\">De acordo com <strong data-start=\"972\" data-end=\"989\">GB\/T 1.1\u20142000<\/strong> (<em data-start=\"991\" data-end=\"1066\">Guia de Trabalho de Padroniza\u00e7\u00e3o \u2013 Parte 1: Estrutura Padr\u00e3o e Regras de Reda\u00e7\u00e3o<\/em>), as seguintes modifica\u00e7\u00f5es editoriais foram feitas \u00e0 norma IEC 60381-2:1978:<br data-start=\"1137\" data-end=\"1140\" \/>a) O termo <strong data-start=\"1152\" data-end=\"1171\">\u201ceste padr\u00e3o\u201d<\/strong> foi alterado para <strong data-start=\"1187\" data-end=\"1203\">\u201cesta parte.\u201d<\/strong><br data-start=\"1203\" data-end=\"1206\" \/>b) O pref\u00e1cio da norma IEC 60381-2:1978 foi removido.<br data-start=\"1253\" data-end=\"1256\" \/>c) Qualquer refer\u00eancia a <strong data-start=\"1276\" data-end=\"1291\">\u201cIEC 60381\u201d<\/strong> foi substitu\u00eddo por <strong data-start=\"1310\" data-end=\"1326\">\u201cGB\/T 3369.\u201d<\/strong><br data-start=\"1326\" data-end=\"1329\" \/>d) A v\u00edrgula decimal <strong data-start=\"1350\" data-end=\"1357\">&#8220;,&#8221;<\/strong> foi substitu\u00eddo por um ponto decimal <strong data-start=\"1392\" data-end=\"1399\">&#8220;.&#8221;<\/strong><\/p><p class=\"\" data-start=\"1403\" data-end=\"1511\">Esta pe\u00e7a substitui <strong data-start=\"1422\" data-end=\"1440\">GB\/T 3370\u20141989<\/strong> (<em data-start=\"1442\" data-end=\"1507\">Sinais de tens\u00e3o CC anal\u00f3gicos para instrumentos de automa\u00e7\u00e3o industrial<\/em>).<\/p><h3 data-start=\"1513\" data-end=\"1559\">\u00a0<\/h3><h3 data-start=\"1513\" data-end=\"1559\">Principais altera\u00e7\u00f5es em compara\u00e7\u00e3o com a norma GB\/T 3370\u20141989:<\/h3><ul data-start=\"1560\" data-end=\"2575\"><li class=\"\" data-start=\"1560\" data-end=\"1756\"><p class=\"\" data-start=\"1562\" data-end=\"1756\">O nome padr\u00e3o foi alterado de <strong data-start=\"1597\" data-end=\"1666\">\u201cSinais de tens\u00e3o CC anal\u00f3gicos para instrumentos de automa\u00e7\u00e3o industrial\u201d<\/strong> para <strong data-start=\"1670\" data-end=\"1754\">\u201cSinais anal\u00f3gicos para sistemas de controle de processos \u2013 Parte 2: Sinais de tens\u00e3o direta.\u201d<\/strong><\/p><\/li><li class=\"\" data-start=\"1757\" data-end=\"1824\"><p class=\"\" data-start=\"1759\" data-end=\"1824\">O termo <strong data-start=\"1768\" data-end=\"1787\">\u201ceste padr\u00e3o\u201d<\/strong> foi substitu\u00eddo por <strong data-start=\"1806\" data-end=\"1822\">\u201cesta parte.\u201d<\/strong><\/p><\/li><li class=\"\" data-start=\"1825\" data-end=\"2119\"><p class=\"\" data-start=\"1827\" data-end=\"1854\"><strong data-start=\"1827\" data-end=\"1852\">\u00c2mbito de aplica\u00e7\u00e3o:<\/strong><\/p><ul data-start=\"1857\" data-end=\"2119\"><li class=\"\" data-start=\"1857\" data-end=\"1967\"><p class=\"\" data-start=\"1859\" data-end=\"1967\"><strong data-start=\"1859\" data-end=\"1877\">GB\/T 3370\u20131989<\/strong> foi baseado em <strong data-start=\"1891\" data-end=\"1911\">IEC 60381-2:1979<\/strong> e aplicado a <strong data-start=\"1927\" data-end=\"1965\">Instrumentos de automa\u00e7\u00e3o industrial.<\/strong><\/p><\/li><li class=\"\" data-start=\"1970\" data-end=\"2119\"><p class=\"\" data-start=\"1972\" data-end=\"2119\"><strong data-start=\"1972\" data-end=\"1992\">GB\/T 3369.2\u20142008<\/strong> \u00e9 um <strong data-start=\"1999\" data-end=\"2022\">ado\u00e7\u00e3o equivalente<\/strong> de <strong data-start=\"2026\" data-end=\"2046\">IEC 60381-2:1979<\/strong> e se aplica a <strong data-start=\"2062\" data-end=\"2117\">Sistemas de medi\u00e7\u00e3o e controle de processos industriais.<\/strong><\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"2120\" data-end=\"2205\"><p class=\"\" data-start=\"2122\" data-end=\"2205\">O termo <strong data-start=\"2131\" data-end=\"2170\">\u201cinstrumentos de automa\u00e7\u00e3o industrial\u201d<\/strong> foi alterado para <strong data-start=\"2186\" data-end=\"2203\">\u201ccomponentes\u201d.<\/strong><\/p><\/li><li class=\"\" data-start=\"2206\" data-end=\"2501\"><p class=\"\" data-start=\"2208\" data-end=\"2328\">O <strong data-start=\"2212\" data-end=\"2232\">\u201cconte\u00fado em cascata\u201d<\/strong> e <strong data-start=\"2237\" data-end=\"2262\">\u201ccomponente CA de sa\u00edda\u201d<\/strong> Defini\u00e7\u00f5es foram removidas e novas defini\u00e7\u00f5es foram adicionadas para:<\/p><ul data-start=\"2331\" data-end=\"2501\"><li class=\"\" data-start=\"2331\" data-end=\"2392\"><p class=\"\" data-start=\"2333\" data-end=\"2392\"><strong data-start=\"2333\" data-end=\"2390\">\u201cValor medido de um sinal de tens\u00e3o cont\u00ednua anal\u00f3gico\u201d<\/strong><\/p><\/li><li class=\"\" data-start=\"2395\" data-end=\"2419\"><p class=\"\" data-start=\"2397\" data-end=\"2419\"><strong data-start=\"2397\" data-end=\"2417\">\u201cImped\u00e2ncia de carga\u201d<\/strong><\/p><\/li><li class=\"\" data-start=\"2422\" data-end=\"2446\"><p class=\"\" data-start=\"2424\" data-end=\"2446\"><strong data-start=\"2424\" data-end=\"2444\">\u201cConte\u00fado Ripple\u201d<\/strong><\/p><\/li><li class=\"\" data-start=\"2449\" data-end=\"2472\"><p class=\"\" data-start=\"2451\" data-end=\"2472\"><strong data-start=\"2451\" data-end=\"2470\">\u201cSinal comum\u201d<\/strong><\/p><\/li><li class=\"\" data-start=\"2475\" data-end=\"2501\"><p class=\"\" data-start=\"2477\" data-end=\"2501\"><strong data-start=\"2477\" data-end=\"2499\">\u201cIsolamento de sinal\u201d<\/strong><\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"2502\" data-end=\"2575\"><p class=\"\" data-start=\"2504\" data-end=\"2575\">A Tabela 1 agora inclui as faixas de sinal. <strong data-start=\"2539\" data-end=\"2552\">0 a +10V<\/strong> e <strong data-start=\"2557\" data-end=\"2573\">-10 a +10V.<\/strong><\/p><\/li><\/ul><h3 data-start=\"2577\" data-end=\"2609\">\u00a0<\/h3><h3 data-start=\"2577\" data-end=\"2609\">Organiza\u00e7\u00f5es Respons\u00e1veis:<\/h3><ul data-start=\"2610\" data-end=\"3176\"><li class=\"\" data-start=\"2610\" data-end=\"2666\"><p class=\"\" data-start=\"2612\" data-end=\"2666\"><strong data-start=\"2612\" data-end=\"2628\">Proposta por:<\/strong> Federa\u00e7\u00e3o da Ind\u00fastria de M\u00e1quinas da China<\/p><\/li><li class=\"\" data-start=\"2667\" data-end=\"2799\"><p class=\"\" data-start=\"2669\" data-end=\"2799\"><strong data-start=\"2669\" data-end=\"2684\">Gerenciado por:<\/strong> Comit\u00ea T\u00e9cnico Nacional de Padroniza\u00e7\u00e3o de Medi\u00e7\u00e3o e Controle de Processos Industriais (Segundo Subcomit\u00ea)<\/p><\/li><li class=\"\" data-start=\"2800\" data-end=\"2882\"><p class=\"\" data-start=\"2802\" data-end=\"2882\"><strong data-start=\"2802\" data-end=\"2828\">Institui\u00e7\u00f5es respons\u00e1veis pela elabora\u00e7\u00e3o do projeto:<\/strong> Universidade do Sudoeste, China Grupo de Instrumentos Silian<\/p><\/li><li class=\"\" data-start=\"2883\" data-end=\"3052\"><p class=\"\" data-start=\"2885\" data-end=\"2918\"><strong data-start=\"2885\" data-end=\"2916\">Institui\u00e7\u00f5es participantes:<\/strong><\/p><ul data-start=\"2921\" data-end=\"3052\"><li class=\"\" data-start=\"2921\" data-end=\"2992\"><p class=\"\" data-start=\"2923\" data-end=\"2992\">Instituto de Pesquisa Econ\u00f4mica e de Instrumentos da Ind\u00fastria de M\u00e1quinas da China<\/p><\/li><li class=\"\" data-start=\"2995\" data-end=\"3052\"><p class=\"\" data-start=\"2997\" data-end=\"3052\">Instituto de Automa\u00e7\u00e3o da Ind\u00fastria de M\u00e1quinas de Pequim<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"3053\" data-end=\"3125\"><p class=\"\" data-start=\"3055\" data-end=\"3125\"><strong data-start=\"3055\" data-end=\"3083\">Equipe principal de reda\u00e7\u00e3o:<\/strong> Liu Feng, Pan Dongbo, Zhang Yu, Liu Jin<\/p><\/li><li class=\"\" data-start=\"3126\" data-end=\"3176\"><p class=\"\" data-start=\"3128\" data-end=\"3176\"><strong data-start=\"3128\" data-end=\"3145\">Colaboradores:<\/strong> Feng Xiaosheng e Xie Bingbing<\/p><\/li><\/ul><p class=\"\" data-start=\"3178\" data-end=\"3218\">Esta pe\u00e7a substitui as normas anteriores:<\/p><ul data-start=\"3219\" data-end=\"3262\"><li class=\"\" data-start=\"3219\" data-end=\"3239\"><p class=\"\" data-start=\"3221\" data-end=\"3239\"><strong data-start=\"3221\" data-end=\"3237\">GB 3370\u20141982<\/strong><\/p><\/li><li class=\"\" data-start=\"3240\" data-end=\"3262\"><p class=\"\" data-start=\"3242\" data-end=\"3262\"><strong data-start=\"3242\" data-end=\"3260\">GB\/T 3370\u20141989<\/strong><\/p><\/li><\/ul><h2 data-start=\"3269\" data-end=\"3355\">\u00a0<\/h2><h2 data-start=\"3269\" data-end=\"3355\"><strong data-start=\"3272\" data-end=\"3353\">Sinais anal\u00f3gicos para sistemas de controle de processos \u2013 Parte 2: Sinais de tens\u00e3o direta<\/strong><\/h2><h3 data-start=\"3357\" data-end=\"3375\">\u00a0<\/h3><h3 data-start=\"3357\" data-end=\"3375\"><strong data-start=\"3361\" data-end=\"3373\">1. \u00c2mbito de aplica\u00e7\u00e3o<\/strong><\/h3><p class=\"\" data-start=\"3376\" data-end=\"3553\">Esta parte aplica-se a <strong data-start=\"3397\" data-end=\"3432\">sinais de tens\u00e3o cont\u00ednua anal\u00f3gicos<\/strong> usado para transmiss\u00e3o de informa\u00e7\u00f5es entre componentes do sistema em <strong data-start=\"3496\" data-end=\"3551\">Sistemas de medi\u00e7\u00e3o e controle de processos industriais.<\/strong><\/p><p class=\"\" data-start=\"3555\" data-end=\"3733\">Ao contr\u00e1rio do <strong data-start=\"3566\" data-end=\"3601\">sinais anal\u00f3gicos de corrente cont\u00ednua<\/strong> especificado em <strong data-start=\"3615\" data-end=\"3635\">GB\/T 3369.1-2008<\/strong>, <strong data-start=\"3637\" data-end=\"3672\">sinais de tens\u00e3o cont\u00ednua anal\u00f3gicos<\/strong> deve <strong data-start=\"3680\" data-end=\"3687\">n\u00e3o<\/strong> ser usado para <strong data-start=\"3700\" data-end=\"3731\">transmiss\u00e3o de longa dist\u00e2ncia.<\/strong><\/p><p class=\"\" data-start=\"3735\" data-end=\"3821\">Esta parte <strong data-start=\"3745\" data-end=\"3757\">n\u00e3o<\/strong> aplicam-se aos sinais usados inteiramente <strong data-start=\"3789\" data-end=\"3819\">dentro de um \u00fanico componente.<\/strong><\/p><h3 data-start=\"3828\" data-end=\"3862\">\u00a0<\/h3><h3 class=\"\" data-start=\"3828\" data-end=\"3862\"><strong data-start=\"3832\" data-end=\"3860\">2. Termos e Defini\u00e7\u00f5es<\/strong><\/h3><h4 class=\"\" data-start=\"3864\" data-end=\"3943\"><strong data-start=\"3869\" data-end=\"3941\">2.1 Componentes dos Sistemas de Medi\u00e7\u00e3o e Controle de Processos Industriais<\/strong><\/h4><p class=\"\" data-start=\"3944\" data-end=\"4123\">Unidades funcionais e dispositivos de combina\u00e7\u00e3o integrados usados para <strong data-start=\"4004\" data-end=\"4121\">Converter, transmitir ou processar valores medidos, quantidades de controle, vari\u00e1veis controladas e vari\u00e1veis de refer\u00eancia.<\/strong><\/p><h4 class=\"\" data-start=\"4125\" data-end=\"4170\"><strong data-start=\"4130\" data-end=\"4168\">2.2 Sinal de Tens\u00e3o Direta Anal\u00f3gica<\/strong><\/h4><p class=\"\" data-start=\"4171\" data-end=\"4316\">UM <strong data-start=\"4173\" data-end=\"4194\">sinal de tens\u00e3o CC<\/strong> que varia continuamente com base em uma ou mais grandezas f\u00edsicas, usadas para <strong data-start=\"4271\" data-end=\"4314\">transmiss\u00e3o ou processamento de informa\u00e7\u00f5es.<\/strong><\/p><h4 class=\"\" data-start=\"4318\" data-end=\"4384\"><strong data-start=\"4323\" data-end=\"4382\">2.3 Valor medido de um sinal de tens\u00e3o cont\u00ednua anal\u00f3gica<\/strong><\/h4><p class=\"\" data-start=\"4385\" data-end=\"4476\">O <strong data-start=\"4389\" data-end=\"4406\">valor m\u00e9dio<\/strong> de um sinal de tens\u00e3o cont\u00ednua anal\u00f3gico <strong data-start=\"4444\" data-end=\"4474\">durante um per\u00edodo de tempo espec\u00edfico.<\/strong><\/p><h4 class=\"\" data-start=\"4478\" data-end=\"4504\"><strong data-start=\"4483\" data-end=\"4502\">2.4 Limite Inferior<\/strong><\/h4><p class=\"\" data-start=\"4505\" data-end=\"4575\">O <strong data-start=\"4509\" data-end=\"4520\">m\u00ednimo<\/strong> Valor de tens\u00e3o do sinal de tens\u00e3o cont\u00ednua anal\u00f3gico.<\/p><h4 class=\"\" data-start=\"4577\" data-end=\"4603\"><strong data-start=\"4582\" data-end=\"4601\">2,5 Limite Superior<\/strong><\/h4><p class=\"\" data-start=\"4604\" data-end=\"4674\">O <strong data-start=\"4608\" data-end=\"4619\">m\u00e1ximo<\/strong> Valor de tens\u00e3o do sinal de tens\u00e3o cont\u00ednua anal\u00f3gico.<\/p><h4 class=\"\" data-start=\"4676\" data-end=\"4733\"><strong data-start=\"4681\" data-end=\"4731\">2.6 Faixa de um sinal de tens\u00e3o cont\u00ednua anal\u00f3gico<\/strong><\/h4><p class=\"\" data-start=\"4734\" data-end=\"4819\">O intervalo definido pelo <strong data-start=\"4759\" data-end=\"4774\">limite inferior<\/strong> e <strong data-start=\"4779\" data-end=\"4794\">limite superior<\/strong> da tens\u00e3o do sinal.<\/p><h4 class=\"\" data-start=\"4821\" data-end=\"4850\"><strong data-start=\"4826\" data-end=\"4848\">2.7 Imped\u00e2ncia de Carga<\/strong><\/h4><p class=\"\" data-start=\"4851\" data-end=\"4904\">A imped\u00e2ncia total de todos <strong data-start=\"4878\" data-end=\"4902\">receptores conectados.<\/strong><\/p><h4 class=\"\" data-start=\"4906\" data-end=\"4935\"><strong data-start=\"4911\" data-end=\"4933\">2.8 Conte\u00fado Ripple<\/strong><\/h4><p class=\"\" data-start=\"4936\" data-end=\"5059\">A propor\u00e7\u00e3o do <strong data-start=\"4953\" data-end=\"4995\">valor pico a pico do componente CA<\/strong> para o <strong data-start=\"5003\" data-end=\"5018\">limite superior<\/strong> do sinal de tens\u00e3o cont\u00ednua anal\u00f3gica.<\/p><h4 class=\"\" data-start=\"5061\" data-end=\"5089\"><strong data-start=\"5066\" data-end=\"5087\">2.9 Sinal Comum<\/strong><\/h4><p class=\"\" data-start=\"5090\" data-end=\"5192\">Uma conex\u00e3o el\u00e9trica comum compartilhada por m\u00faltiplos circuitos de sinal, que pode ou n\u00e3o estar aterrada.<\/p><h4 class=\"\" data-start=\"5194\" data-end=\"5226\"><strong data-start=\"5199\" data-end=\"5224\">2.10 Isolamento de Sinal<\/strong><\/h4><p class=\"\" data-start=\"5227\" data-end=\"5339\">A aus\u00eancia de <strong data-start=\"5242\" data-end=\"5268\">conex\u00f5es el\u00e9tricas<\/strong> entre o <strong data-start=\"5281\" data-end=\"5299\">circuito de sinal<\/strong> e outros circuitos ou o <strong data-start=\"5326\" data-end=\"5337\">ch\u00e3o.<\/strong><\/p><h3 data-start=\"5346\" data-end=\"5381\">\u00a0<\/h3><h3 class=\"\" data-start=\"5346\" data-end=\"5381\"><strong data-start=\"5350\" data-end=\"5379\">3. Requisitos t\u00e9cnicos<\/strong><\/h3><h4 class=\"\" data-start=\"5383\" data-end=\"5438\"><strong data-start=\"5388\" data-end=\"5436\">3.1 Faixa de sinais de tens\u00e3o direta anal\u00f3gica<\/strong><\/h4><p class=\"\" data-start=\"5439\" data-end=\"5493\">A Tabela 1 apresenta as faixas de sinal de tens\u00e3o padr\u00e3o.<\/p><div class=\"overflow-x-auto contain-inline-size\"><table data-start=\"5495\" data-end=\"5720\"><thead data-start=\"5495\" data-end=\"5534\"><tr data-start=\"5495\" data-end=\"5534\"><th data-start=\"5495\" data-end=\"5513\">Limite inferior (V)<\/th><th data-start=\"5513\" data-end=\"5534\">Limite superior (V)<\/th><\/tr><\/thead><tbody data-start=\"5573\" data-end=\"5720\"><tr data-start=\"5573\" data-end=\"5609\"><td>+1<\/td><td>+5<\/td><\/tr><tr data-start=\"5610\" data-end=\"5646\"><td>0<\/td><td>+5<\/td><\/tr><tr data-start=\"5647\" data-end=\"5683\"><td>0<\/td><td>+10<\/td><\/tr><tr data-start=\"5684\" data-end=\"5720\"><td>-10<\/td><td>+10<\/td><\/tr><\/tbody><\/table><\/div><p class=\"\" data-start=\"5722\" data-end=\"5734\"><strong data-start=\"5722\" data-end=\"5732\">Notas:<\/strong><\/p><ul data-start=\"5735\" data-end=\"5938\"><li class=\"\" data-start=\"5735\" data-end=\"5845\"><p class=\"\" data-start=\"5737\" data-end=\"5845\">Sinais de tens\u00e3o <strong data-start=\"5753\" data-end=\"5771\">pode ser derivado<\/strong> a partir de sinais anal\u00f3gicos de corrente cont\u00ednua especificados em <strong data-start=\"5822\" data-end=\"5843\">GB\/T 3369.1\u20142008.<\/strong><\/p><\/li><li class=\"\" data-start=\"5846\" data-end=\"5938\"><p class=\"\" data-start=\"5848\" data-end=\"5938\">Sinais de tens\u00e3o <strong data-start=\"5864\" data-end=\"5871\">pode<\/strong> representar quantidades f\u00edsicas usando <strong data-start=\"5908\" data-end=\"5936\">caracter\u00edsticas bipolares.<\/strong><\/p><\/li><\/ul><h4 class=\"\" data-start=\"5945\" data-end=\"5974\"><strong data-start=\"5950\" data-end=\"5972\">3.2 Conte\u00fado Ripple<\/strong><\/h4><p class=\"\" data-start=\"5975\" data-end=\"6057\">Ao usar <strong data-start=\"5986\" data-end=\"6019\">fontes de alimenta\u00e7\u00e3o CC sem ondula\u00e7\u00e3o<\/strong>, o seguinte deve ser especificado:<\/p><ul data-start=\"6058\" data-end=\"6274\"><li class=\"\" data-start=\"6058\" data-end=\"6124\"><p class=\"\" data-start=\"6060\" data-end=\"6124\"><strong data-start=\"6060\" data-end=\"6092\">Conte\u00fado e frequ\u00eancia das ondula\u00e7\u00f5es<\/strong> dentro dos componentes do sistema.<\/p><\/li><li class=\"\" data-start=\"6125\" data-end=\"6192\"><p class=\"\" data-start=\"6127\" data-end=\"6192\"><strong data-start=\"6127\" data-end=\"6150\">Ru\u00eddo e frequ\u00eancia<\/strong> gerado dentro dos componentes do sistema.<\/p><\/li><li class=\"\" data-start=\"6193\" data-end=\"6274\"><p class=\"\" data-start=\"6195\" data-end=\"6274\">Conte\u00fado ondulado causado por <strong data-start=\"6220\" data-end=\"6246\">ondula\u00e7\u00e3o da fonte de alimenta\u00e7\u00e3o CC<\/strong> tamb\u00e9m deve ser especificado.<\/p><\/li><\/ul><h4 class=\"\" data-start=\"6281\" data-end=\"6314\"><strong data-start=\"6286\" data-end=\"6312\">3.3 Linha Comum de Sinal<\/strong><\/h4><ul data-start=\"6315\" data-end=\"6705\"><li class=\"\" data-start=\"6315\" data-end=\"6511\"><p class=\"\" data-start=\"6317\" data-end=\"6511\">Para <strong data-start=\"6321\" data-end=\"6341\">sinais unipolares<\/strong>, o <strong data-start=\"6347\" data-end=\"6368\">terminal negativo<\/strong> serve como linha comum de sinal. Se conectado a um <strong data-start=\"6421\" data-end=\"6440\">fonte de alimenta\u00e7\u00e3o CC<\/strong>deve conectar-se ao <strong data-start=\"6467\" data-end=\"6488\">terminal negativo<\/strong> da fonte de alimenta\u00e7\u00e3o.<\/p><\/li><li class=\"\" data-start=\"6512\" data-end=\"6705\"><p class=\"\" data-start=\"6514\" data-end=\"6705\">Para <strong data-start=\"6518\" data-end=\"6537\">sinais bipolares<\/strong>, o <strong data-start=\"6543\" data-end=\"6563\">terminal neutro<\/strong> serve como linha comum de sinal. Se conectado a um <strong data-start=\"6616\" data-end=\"6635\">fonte de alimenta\u00e7\u00e3o CC<\/strong>deve conectar-se ao <strong data-start=\"6662\" data-end=\"6682\">terminal neutro<\/strong> da fonte de alimenta\u00e7\u00e3o.<\/p><\/li><\/ul><h4 class=\"\" data-start=\"6712\" data-end=\"6736\"><strong data-start=\"6717\" data-end=\"6734\">3.4 Aterramento<\/strong><\/h4><ul data-start=\"6737\" data-end=\"7033\"><li class=\"\" data-start=\"6737\" data-end=\"6888\"><p class=\"\" data-start=\"6739\" data-end=\"6888\">Para <strong data-start=\"6743\" data-end=\"6763\">sinais unipolares<\/strong>, se o componente for <strong data-start=\"6785\" data-end=\"6797\">de castigo<\/strong>, o <strong data-start=\"6803\" data-end=\"6824\">terminal negativo<\/strong> O sinal e\/ou a fonte de alimenta\u00e7\u00e3o CC tamb\u00e9m devem ser aterrados.<\/p><\/li><li class=\"\" data-start=\"6889\" data-end=\"7033\"><p class=\"\" data-start=\"6891\" data-end=\"7033\">Para <strong data-start=\"6895\" data-end=\"6914\">sinais bipolares<\/strong>, se o componente for <strong data-start=\"6936\" data-end=\"6948\">de castigo<\/strong>, o <strong data-start=\"6954\" data-end=\"6974\">terminal neutro<\/strong> O sinal e\/ou a fonte de alimenta\u00e7\u00e3o CC devem ser aterrados.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Normas aplic\u00e1veis para sinais de tens\u00e3o de atuadores el\u00e9tricos (1-5V, 2-10V, 0-5V, 0-10V): Sinais anal\u00f3gicos para sistemas de controle de processos \u2013 Parte 2: Sinais de tens\u00e3o direta (GB\/T 3369.2\u20142008\/IEC 60381-2:1978) IEC 60381-2-1978, Pref\u00e1cio da IDT GB\/T 3369.2\u20142008\/IEC 60381-2:1978 \u2013 Sinais anal\u00f3gicos para sistemas de controle de processos \u2013 Parte 2: Sinais de tens\u00e3o direta A norma GB\/T 3369 consiste nas seguintes duas partes: [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[3],"tags":[49],"class_list":["post-6537","post","type-post","status-publish","format-standard","hentry","category-ts-actuator","tag-input-signal"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/posts\/6537","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/comments?post=6537"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/posts\/6537\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/media?parent=6537"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/categories?post=6537"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/tags?post=6537"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}