{"id":6034,"date":"2023-08-03T20:40:54","date_gmt":"2023-08-03T12:40:54","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6034"},"modified":"2025-03-27T09:36:11","modified_gmt":"2025-03-27T09:36:11","slug":"dcl-02-modulating-actuator","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/pt_pt\/apoio\/atuador-mr\/dcl-02-atuador-modulante","title":{"rendered":"Problemas comuns e solu\u00e7\u00e3o de problemas para atuadores moduladores DCL-02"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6034\" class=\"elementor elementor-6034\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4d0a73a e-con-full e-flex e-con e-parent\" data-id=\"4d0a73a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-074db40 e-con-full e-flex e-con e-child\" data-id=\"074db40\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c0eba31 elementor-widget elementor-widget-text-editor\" data-id=\"c0eba31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Este guia aplica-se aos atuadores moduladores ultracompactos da DCL, modelo a seguir:<\/p><p>DCL-02E<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-baf5aaf elementor-widget elementor-widget-image\" data-id=\"baf5aaf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-02-valve.webp\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4622d9 elementor-widget elementor-widget-heading\" data-id=\"b4622d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Falhas comuns e m\u00e9todos de resolu\u00e7\u00e3o de problemas<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e06e825 elementor-widget elementor-widget-text-editor\" data-id=\"e06e825\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>\u00a0<\/h3><table><thead><tr><th><strong>Falta<\/strong><\/th><th><strong>Poss\u00edvel causa<\/strong><\/th><th><strong>M\u00e9todo de resolu\u00e7\u00e3o de problemas<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>O atuador n\u00e3o abre nem fecha na inicializa\u00e7\u00e3o.<\/strong><\/td><td>1. Fia\u00e7\u00e3o incorreta<\/td><td>Verifique a fia\u00e7\u00e3o de acordo com o diagrama de fia\u00e7\u00e3o do atuador para confirmar se est\u00e1 correta.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Fonte de alimenta\u00e7\u00e3o incorreta<\/td><td>Certifique-se de que a tens\u00e3o de sa\u00edda da fonte de alimenta\u00e7\u00e3o esteja dentro de \u00b110% da tens\u00e3o nominal do atuador e que a corrente seja 3 vezes a corrente nominal do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Interruptor ou rel\u00e9 de controle anormal<\/td><td>Me\u00e7a a tens\u00e3o de entrada no terminal de controle do interruptor do atuador com um mult\u00edmetro para garantir que ela corresponda ao valor esperado.<\/td><\/tr><tr><td>\u00a0<\/td><td>4. Incompatibilidade do sistema de controle<\/td><td>Utilize um interruptor mec\u00e2nico para testar a funcionalidade do atuador. Se o atuador funcionar corretamente, verifique a l\u00f3gica de sa\u00edda do sistema de controle.<\/td><\/tr><tr><td>\u00a0<\/td><td>5. M\u00faltiplos atuadores ou conex\u00e3o paralela de atuadores com outros dispositivos<\/td><td>Os atuadores do tipo interruptor come\u00e7am com um capacitor. A conex\u00e3o em paralelo com outros dispositivos afetar\u00e1 o valor do capacitor. Os atuadores do tipo interruptor devem ser usados apenas com controle individual, n\u00e3o com controle em paralelo.<\/td><\/tr><tr><td><strong>O atuador s\u00f3 pode abrir ou fechar.<\/strong><\/td><td>1. Fia\u00e7\u00e3o incorreta<\/td><td>1. Utilize um interruptor mec\u00e2nico para testar a funcionalidade do atuador. Se funcionar corretamente, verifique a l\u00f3gica de sa\u00edda do sistema de controle.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. Verifique a fia\u00e7\u00e3o de acordo com o diagrama de fia\u00e7\u00e3o do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Configura\u00e7\u00e3o incorreta da c\u00e2mera de abertura\/fechamento total<\/td><td>Consulte \u201cComo ajustar v\u00e1lvulas el\u00e9tricas do tipo interruptor\u201d para o posicionamento correto da came.<\/td><\/tr><tr><td><strong>O atuador para no meio do curso.<\/strong><\/td><td>1. Travamento da v\u00e1lvula<\/td><td>Verifique se a v\u00e1lvula est\u00e1 emperrada, remova o bloqueio e tente novamente ap\u00f3s o resfriamento da prote\u00e7\u00e3o contra sobrecarga do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Part\u00edculas s\u00f3lidas no fluido causando travamento da v\u00e1lvula<\/td><td>Verifique se h\u00e1 part\u00edculas s\u00f3lidas no fluido causando o travamento da v\u00e1lvula, remova o bloqueio e tente novamente ap\u00f3s o resfriamento da prote\u00e7\u00e3o contra sobrecarga do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Configura\u00e7\u00e3o incorreta do bloco de parada de abertura\/fechamento total<\/td><td>Consulte a se\u00e7\u00e3o \u201cComo configurar v\u00e1lvulas el\u00e9tricas do tipo interruptor\u201d para ajustar corretamente a posi\u00e7\u00e3o do bloco de parada.<\/td><\/tr><tr><td><strong>N\u00e3o \u00e9 poss\u00edvel girar o atuador usando a alavanca.<\/strong><\/td><td>1. Part\u00edculas s\u00f3lidas no fluido causando o travamento da v\u00e1lvula<\/td><td>Verifique se part\u00edculas s\u00f3lidas est\u00e3o causando o travamento da v\u00e1lvula, remova o bloqueio e tente novamente ap\u00f3s o resfriamento da prote\u00e7\u00e3o contra sobrecarga do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. A v\u00e1lvula est\u00e1 presa<\/td><td>Verifique se a v\u00e1lvula est\u00e1 presa, remova o bloqueio e tente novamente ap\u00f3s o resfriamento da prote\u00e7\u00e3o contra sobrecarga do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Mecanismo de desacelera\u00e7\u00e3o do atuador danificado<\/td><td>Remova o atuador da v\u00e1lvula e gire a alavanca. Se ela n\u00e3o girar, substitua-a por um atuador novo.<\/td><\/tr><tr><td><strong>Sem sa\u00edda do sinal de feedback de posi\u00e7\u00e3o<\/strong><\/td><td>1. Fia\u00e7\u00e3o incorreta do interruptor<\/td><td>Verifique a fia\u00e7\u00e3o de acordo com o diagrama de fia\u00e7\u00e3o do atuador para confirmar se est\u00e1 correta.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Configura\u00e7\u00e3o incorreta da c\u00e2mera de abertura\/fechamento total<\/td><td>Consulte a se\u00e7\u00e3o \u201cComo ajustar v\u00e1lvulas el\u00e9tricas do tipo interruptor\u201d para ajustar corretamente a posi\u00e7\u00e3o da came.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Sobrecorrente causando falha no interruptor de feedback de posi\u00e7\u00e3o<\/td><td>1. Consulte \u201cComo configurar v\u00e1lvulas el\u00e9tricas do tipo interruptor\u201d para verificar se a came de abertura total\/fechamento total est\u00e1 pressionando corretamente o interruptor de feedback de posi\u00e7\u00e3o.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. Verifique se o circuito de feedback de posi\u00e7\u00e3o est\u00e1 conectado.<\/td><\/tr><\/tbody><\/table><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6802156 elementor-widget elementor-widget-heading\" data-id=\"6802156\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2. Verificar as condi\u00e7\u00f5es de compatibilidade da aplica\u00e7\u00e3o<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be9bb57 elementor-widget elementor-widget-text-editor\" data-id=\"be9bb57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5234\" data-end=\"5479\">Os atuadores el\u00e9tricos podem falhar se forem usados incorretamente ou em condi\u00e7\u00f5es de aplica\u00e7\u00e3o inadequadas. Garantir que o atuador opere dentro das especifica\u00e7\u00f5es definidas na ficha t\u00e9cnica do produto ajudar\u00e1 a assegurar um funcionamento sem problemas a longo prazo.<\/p><ul data-start=\"5481\" data-end=\"6708\" data-is-only-node=\"\"><li class=\"\" data-start=\"5481\" data-end=\"5667\"><p class=\"\" data-start=\"5483\" data-end=\"5667\"><strong data-start=\"5483\" data-end=\"5507\">Tens\u00e3o da fonte de alimenta\u00e7\u00e3o<\/strong>A tens\u00e3o da fonte de alimenta\u00e7\u00e3o deve estar dentro da faixa de tens\u00e3o operacional nominal do atuador. Sobretens\u00e3o ou subtens\u00e3o podem reduzir a vida \u00fatil do atuador.<\/p><\/li><li class=\"\" data-start=\"5671\" data-end=\"5866\"><p class=\"\" data-start=\"5673\" data-end=\"5866\"><strong data-start=\"5673\" data-end=\"5697\">Corrente da fonte de alimenta\u00e7\u00e3o<\/strong>Como a corrente de partida do motor \u00e9 muito maior que a corrente nominal, certifique-se de que a fonte de alimenta\u00e7\u00e3o tenha pelo menos 3 vezes a capacidade de corrente nominal do atuador.<\/p><\/li><li class=\"\" data-start=\"5868\" data-end=\"6082\"><p class=\"\" data-start=\"5870\" data-end=\"6082\"><strong data-start=\"5870\" data-end=\"5885\">Temperatura<\/strong>Certifique-se de que o atuador opere dentro da sua faixa de temperatura nominal. O uso do atuador fora da faixa de temperatura nominal pode levar a mau funcionamento ou redu\u00e7\u00e3o da vida \u00fatil, causando, em \u00faltima inst\u00e2ncia, falha.<\/p><\/li><li class=\"\" data-start=\"6084\" data-end=\"6498\"><p class=\"\" data-start=\"6086\" data-end=\"6498\"><strong data-start=\"6086\" data-end=\"6101\">Ambiente<\/strong>Os atuadores tipo interruptor da DCL possuem classifica\u00e7\u00e3o IP67 de resist\u00eancia \u00e0s intemp\u00e9ries, sendo adequados para uso interno e externo. Eles oferecem alguma prote\u00e7\u00e3o contra chuva, respingos de \u00e1gua e raios UV (luz solar), o que normalmente prolonga a vida \u00fatil do produto. No entanto, ambientes altamente corrosivos podem causar falhas prematuras dos componentes eletr\u00f4nicos. N\u00e3o utilize atuadores da s\u00e9rie n\u00e3o \u00e0 prova de explos\u00e3o em ambientes perigosos.<\/p><\/li><li class=\"\" data-start=\"6500\" data-end=\"6708\"><p class=\"\" data-start=\"6502\" data-end=\"6708\"><strong data-start=\"6502\" data-end=\"6516\">Ciclo de trabalho<\/strong>O atuador tipo interruptor DCL possui um ciclo de trabalho de 70% (42 segundos de opera\u00e7\u00e3o seguidos por 18 segundos de repouso). Exceder esse ciclo de trabalho pode fazer com que o motor entre no modo de prote\u00e7\u00e3o t\u00e9rmica.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-823dd6a elementor-widget elementor-widget-heading\" data-id=\"823dd6a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Verifique a fia\u00e7\u00e3o do atuador.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-32ec269 elementor-widget elementor-widget-text-editor\" data-id=\"32ec269\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"41\" data-end=\"104\">Para garantir o funcionamento correto do atuador, siga estes passos:<\/p><ol data-start=\"106\" data-end=\"1403\"><li class=\"\" data-start=\"106\" data-end=\"331\"><p class=\"\" data-start=\"109\" data-end=\"156\"><strong data-start=\"109\" data-end=\"156\">Verifique a fia\u00e7\u00e3o de acordo com o diagrama:<\/strong><\/p><ul data-start=\"160\" data-end=\"331\"><li class=\"\" data-start=\"160\" data-end=\"237\"><p class=\"\" data-start=\"162\" data-end=\"237\">Verifique novamente a fia\u00e7\u00e3o para garantir que ela corresponda ao diagrama de fia\u00e7\u00e3o do atuador.<\/p><\/li><li class=\"\" data-start=\"241\" data-end=\"327\"><p class=\"\" data-start=\"243\" data-end=\"327\">Confirme se todas as conex\u00f5es est\u00e3o seguras e se nenhum fio est\u00e1 solto ou desconectado.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"332\" data-end=\"558\"><p class=\"\" data-start=\"335\" data-end=\"366\"><strong data-start=\"335\" data-end=\"366\">Verifique a polaridade correta:<\/strong><\/p><ul data-start=\"370\" data-end=\"558\"><li class=\"\" data-start=\"370\" data-end=\"483\"><p class=\"\" data-start=\"372\" data-end=\"483\">Certifique-se de que os terminais positivo e negativo da fonte de alimenta\u00e7\u00e3o estejam conectados aos terminais corretos do atuador.<\/p><\/li><li class=\"\" data-start=\"487\" data-end=\"558\"><p class=\"\" data-start=\"489\" data-end=\"558\">A polaridade incorreta pode causar mau funcionamento ou danos ao atuador.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"560\" data-end=\"787\"><p class=\"\" data-start=\"563\" data-end=\"601\"><strong data-start=\"563\" data-end=\"601\">Inspecione a fia\u00e7\u00e3o do sinal de controle:<\/strong><\/p><ul data-start=\"605\" data-end=\"787\"><li class=\"\" data-start=\"605\" data-end=\"687\"><p class=\"\" data-start=\"607\" data-end=\"687\">Verifique a fia\u00e7\u00e3o dos sinais de controle (ex.: sinal de entrada, sinal de feedback).<\/p><\/li><li class=\"\" data-start=\"691\" data-end=\"787\"><p class=\"\" data-start=\"693\" data-end=\"787\">Certifique-se de que os fios de sinal estejam conectados corretamente e sem curtos-circuitos ou interrup\u00e7\u00f5es.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"789\" data-end=\"1011\"><p class=\"\" data-start=\"792\" data-end=\"816\"><strong data-start=\"792\" data-end=\"816\">Verificar aterramento:<\/strong><\/p><ul data-start=\"820\" data-end=\"1011\"><li class=\"\" data-start=\"820\" data-end=\"929\"><p class=\"\" data-start=\"822\" data-end=\"929\">Assegure-se de que o atuador esteja devidamente aterrado para evitar interfer\u00eancias de ru\u00eddo el\u00e9trico ou poss\u00edveis curtos-circuitos.<\/p><\/li><li class=\"\" data-start=\"933\" data-end=\"1011\"><p class=\"\" data-start=\"935\" data-end=\"1011\">Uma liga\u00e7\u00e3o \u00e0 terra defeituosa pode causar comportamento err\u00e1tico ou falha de funcionamento.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"1013\" data-end=\"1212\"><p class=\"\" data-start=\"1016\" data-end=\"1063\"><strong data-start=\"1016\" data-end=\"1063\">Confirme a fia\u00e7\u00e3o dos componentes externos:<\/strong><\/p><ul data-start=\"1067\" data-end=\"1212\"><li class=\"\" data-start=\"1067\" data-end=\"1208\"><p class=\"\" data-start=\"1069\" data-end=\"1208\">Se dispositivos externos, como interruptores de limite, sensores ou m\u00f3dulos de controle adicionais, estiverem conectados, verifique se a fia\u00e7\u00e3o est\u00e1 segura e correta.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"1213\" data-end=\"1403\"><p class=\"\" data-start=\"1216\" data-end=\"1245\"><strong data-start=\"1216\" data-end=\"1245\">Teste o circuito de controle:<\/strong><\/p><ul data-start=\"1249\" data-end=\"1403\"><li class=\"\" data-start=\"1249\" data-end=\"1351\"><p class=\"\" data-start=\"1251\" data-end=\"1351\">Utilize um mult\u00edmetro para verificar o circuito de controle, incluindo a tens\u00e3o de entrada nos terminais de controle.<\/p><\/li><li class=\"\" data-start=\"1355\" data-end=\"1403\"><p class=\"\" data-start=\"1357\" data-end=\"1403\">Confirme se a faixa de tens\u00e3o esperada est\u00e1 presente.<\/p><\/li><\/ul><\/li><\/ol><p class=\"\" data-start=\"1405\" data-end=\"1634\">Ap\u00f3s confirmar se a fia\u00e7\u00e3o est\u00e1 correta, prossiga com o teste do atuador para garantir seu funcionamento adequado. Se algum problema persistir ap\u00f3s a verifica\u00e7\u00e3o da fia\u00e7\u00e3o, pode ser necess\u00e1rio inspecionar mais detalhadamente os componentes internos do atuador.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-422047d elementor-widget elementor-widget-template\" data-id=\"422047d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"template.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-template\">\n\t\t\t\t\t<div data-elementor-type=\"section\" data-elementor-id=\"10970\" class=\"elementor elementor-10970\" data-elementor-post-type=\"elementor_library\">\n\t\t\t<div class=\"elementor-element elementor-element-19a6173 e-flex e-con-boxed e-con e-parent\" data-id=\"19a6173\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-984e463 e-con-full e-flex e-con e-child\" data-id=\"984e463\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d08c8ca elementor-widget elementor-widget-heading\" data-id=\"d08c8ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">E - Modula\u00e7\u00e3o com uma unidade de controlo<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e3dcbb5 elementor-widget elementor-widget-image\" data-id=\"e3dcbb5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"400\" height=\"330\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-e.webp\" class=\"attachment-full size-full wp-image-4857\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668E\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4396a8e elementor-widget elementor-widget-text-editor\" data-id=\"4396a8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Entrada: 4~20mA \/ 0~10V<\/li><li>Sa\u00edda: 4~20mA \/ 0~10V<\/li><\/ul><p>\u00a0<\/p><p><strong>Detalhes de liga\u00e7\u00e3o:<\/strong><\/p><ol><li>Ligar a linha de alimenta\u00e7\u00e3o AC85-220V a L e o neutro a N.<\/li><li>Liga\u00e7\u00e3o da fonte do sinal de entrada 4-20mA\/2-10V do sistema de controlo \u00e0 entrada-\/+.<\/li><li>Ligar a sa\u00edda -\/+ ao sistema para enviar a posi\u00e7\u00e3o da v\u00e1lvula em tempo real.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ff65758 e-con-full e-flex e-con e-parent\" data-id=\"ff65758\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-d5dc048 e-con-full e-flex e-con e-child\" data-id=\"d5dc048\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-527200f elementor-widget elementor-widget-text-editor\" data-id=\"527200f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nota\uff1a<\/p><ul><li>O circuito dentro da caixa tracejada \u00e9 o circuito interno do atuador. Enquanto o circuito exterior \u00e9 uma demonstra\u00e7\u00e3o da liga\u00e7\u00e3o el\u00e9ctrica para utilizar o atuador.<\/li><li>Se tiver outros requisitos espec\u00edficos sobre o circuito de liga\u00e7\u00e3o, n\u00e3o hesite em contactar o nosso apoio t\u00e9cnico.\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-09f9fde elementor-widget elementor-widget-text-editor\" data-id=\"09f9fde\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ao solucionar problemas no local, voc\u00ea pode entrar em contato imediatamente com nossa equipe de assist\u00eancia t\u00e9cnica para que juntos possamos analisar o problema e determinar a solu\u00e7\u00e3o.<\/p><p>N\u00famero de contato: 13026331611 (Sr. Chen)<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Este guia aplica-se aos atuadores moduladores ultracompactos DCL, modelo DCL-02E. Falhas comuns e m\u00e9todos de resolu\u00e7\u00e3o de problemas: Falha Causa poss\u00edvel M\u00e9todo de resolu\u00e7\u00e3o de problemas O atuador n\u00e3o abre nem fecha na inicializa\u00e7\u00e3o 1. Fia\u00e7\u00e3o incorreta Verifique a fia\u00e7\u00e3o de acordo com o diagrama de fia\u00e7\u00e3o do atuador para confirmar se est\u00e1 correta. 2. Fonte de alimenta\u00e7\u00e3o incorreta [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[103],"tags":[53],"class_list":["post-6034","post","type-post","status-publish","format-standard","hentry","category-mr-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/posts\/6034","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/comments?post=6034"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/posts\/6034\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/media?parent=6034"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/categories?post=6034"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/tags?post=6034"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}