{"id":6033,"date":"2023-08-03T20:44:54","date_gmt":"2023-08-03T12:44:54","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6033"},"modified":"2025-03-27T09:47:56","modified_gmt":"2025-03-27T09:47:56","slug":"dcl-02-on-off-actuator","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/pt_pt\/apoio\/atuador-mr\/atuador-liga-desliga-dcl-02","title":{"rendered":"Problemas comuns e solu\u00e7\u00e3o de problemas para atuadores liga\/desliga DCL-02"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6033\" class=\"elementor elementor-6033\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-23bbd22 e-con-full e-flex e-con e-parent\" data-id=\"23bbd22\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-add184b e-con-full e-flex e-con e-child\" data-id=\"add184b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ec8fa0c elementor-widget elementor-widget-text-editor\" data-id=\"ec8fa0c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"0\" data-end=\"92\">Este guia aplica-se aos atuadores da s\u00e9rie DCL Ultra-Small, com os seguintes modelos:<\/p><ul data-start=\"94\" data-end=\"123\"><li class=\"\" data-start=\"94\" data-end=\"103\"><p class=\"\" data-start=\"96\" data-end=\"103\">DCL-02A<\/p><\/li><li class=\"\" data-start=\"104\" data-end=\"113\"><p class=\"\" data-start=\"106\" data-end=\"113\">DCL-02B<\/p><\/li><li class=\"\" data-start=\"114\" data-end=\"123\"><p class=\"\" data-start=\"116\" data-end=\"123\">DCL-02G<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69c14e5 elementor-widget elementor-widget-image\" data-id=\"69c14e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"176\" height=\"399\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/dcl-02-valve.webp\" class=\"attachment-full size-full wp-image-4861\" alt=\"\u534e\u6613\u7cbe\u5de7\u7cfb\u5217\u6267\u884c\u5668 DCL-02 \u914d\u9600 | V\u00e1lvula Atuadora DCL-02\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b43d346 elementor-widget elementor-widget-heading\" data-id=\"b43d346\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Falhas comuns e m\u00e9todos de resolu\u00e7\u00e3o de problemas<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1d44fb elementor-widget elementor-widget-text-editor\" data-id=\"e1d44fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0<\/p><table><thead><tr><th><strong>Falta<\/strong><\/th><th><strong>Poss\u00edveis causas<\/strong><\/th><th><strong>M\u00e9todos de resolu\u00e7\u00e3o de problemas<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>O atuador n\u00e3o abre nem fecha na partida inicial.<\/strong><\/td><td>1. Fia\u00e7\u00e3o incorreta<\/td><td>Verifique a fia\u00e7\u00e3o de acordo com o diagrama de fia\u00e7\u00e3o do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Fonte de alimenta\u00e7\u00e3o incorreta<\/td><td>Certifique-se de que a tens\u00e3o da fonte de alimenta\u00e7\u00e3o esteja dentro de \u00b110% da tens\u00e3o nominal do atuador e que a corrente seja 3 vezes a corrente nominal.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Interruptor de controle ou rel\u00e9 com defeito<\/td><td>Me\u00e7a a tens\u00e3o de entrada no terminal de controle do atuador usando um mult\u00edmetro para verificar se ela corresponde ao esperado.<\/td><\/tr><tr><td>\u00a0<\/td><td>4. Incompatibilidade do sistema de controle<\/td><td>Teste o atuador com um interruptor mec\u00e2nico. Se funcionar normalmente, verifique a l\u00f3gica de sa\u00edda do sistema de controle.<\/td><\/tr><tr><td>\u00a0<\/td><td>5. M\u00faltiplos atuadores ou atuadores e outros dispositivos conectados em paralelo<\/td><td>Os atuadores de interruptor devem usar controle de caminho \u00fanico e n\u00e3o devem ser conectados em paralelo, pois isso afeta o capacitor de partida.<\/td><\/tr><tr><td><strong>O atuador s\u00f3 pode abrir ou fechar.<\/strong><\/td><td>1. Fia\u00e7\u00e3o incorreta<\/td><td>Verifique a fia\u00e7\u00e3o utilizando o diagrama de fia\u00e7\u00e3o do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Configura\u00e7\u00e3o incorreta da c\u00e2mera de abertura\/fechamento total<\/td><td>Consulte o guia \u201cComo ajustar v\u00e1lvulas el\u00e9tricas do tipo interruptor\u201d e ajuste corretamente as posi\u00e7\u00f5es da came.<\/td><\/tr><tr><td><strong>O atuador para no meio do percurso.<\/strong><\/td><td>1. V\u00e1lvula emperrada<\/td><td>Verifique se h\u00e1 obstru\u00e7\u00f5es na v\u00e1lvula. Remova qualquer obstru\u00e7\u00e3o e tente novamente ap\u00f3s o resfriamento da prote\u00e7\u00e3o contra sobrecarga do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Material s\u00f3lido no fluido causando obstru\u00e7\u00e3o da v\u00e1lvula<\/td><td>Inspecione o fluido em busca de part\u00edculas s\u00f3lidas que possam estar causando o travamento da v\u00e1lvula. Remova o travamento e tente novamente ap\u00f3s o resfriamento da prote\u00e7\u00e3o contra sobrecarga do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Configura\u00e7\u00e3o incorreta do batente de abertura\/fechamento total<\/td><td>Consulte o guia \u201cComo configurar v\u00e1lvulas el\u00e9tricas do tipo interruptor\u201d e ajuste corretamente as posi\u00e7\u00f5es dos registros.<\/td><\/tr><tr><td><strong>N\u00e3o \u00e9 poss\u00edvel girar o atuador usando a alavanca.<\/strong><\/td><td>1. Material s\u00f3lido no fluido causando o travamento da v\u00e1lvula.<\/td><td>Verifique se h\u00e1 obstru\u00e7\u00e3o na v\u00e1lvula. Remova a obstru\u00e7\u00e3o e tente novamente ap\u00f3s o resfriamento da prote\u00e7\u00e3o contra sobrecarga do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Travamento da v\u00e1lvula<\/td><td>Verifique se a v\u00e1lvula est\u00e1 travada. Remova o bloqueio e tente novamente ap\u00f3s o resfriamento da prote\u00e7\u00e3o contra sobrecarga do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Mecanismo de redu\u00e7\u00e3o do atuador danificado<\/td><td>Remova o atuador da v\u00e1lvula e gire a alavanca. Se ela n\u00e3o se mover, substitua o atuador.<\/td><\/tr><tr><td><strong>Sem sinal de feedback de posi\u00e7\u00e3o<\/strong><\/td><td>1. Fia\u00e7\u00e3o incorreta no interruptor<\/td><td>Verifique a fia\u00e7\u00e3o de acordo com o diagrama de fia\u00e7\u00e3o do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Configura\u00e7\u00e3o incorreta da c\u00e2mera de abertura\/fechamento total<\/td><td>Consulte o guia \u201cComo ajustar v\u00e1lvulas el\u00e9tricas do tipo interruptor\u201d e ajuste a posi\u00e7\u00e3o da came corretamente.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Sobrecorrente causando danos ao interruptor de feedback de posi\u00e7\u00e3o<\/td><td>1. Verifique se a came de abertura\/fechamento total est\u00e1 pressionando corretamente o interruptor de feedback de posi\u00e7\u00e3o, conforme o guia.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. Verifique se o circuito de feedback de posi\u00e7\u00e3o est\u00e1 fechado.<\/td><\/tr><\/tbody><\/table><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d58177d elementor-widget elementor-widget-heading\" data-id=\"d58177d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Verifique se as condi\u00e7\u00f5es de opera\u00e7\u00e3o atendem aos requisitos dos par\u00e2metros.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60cdda7 elementor-widget elementor-widget-text-editor\" data-id=\"60cdda7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"156\" data-end=\"422\">Os atuadores el\u00e9tricos podem falhar devido ao uso inadequado ou \u00e0 opera\u00e7\u00e3o em condi\u00e7\u00f5es incorretas. Quando utilizados dentro das condi\u00e7\u00f5es operacionais definidas nas especifica\u00e7\u00f5es do produto, espera-se que o atuador funcione de forma confi\u00e1vel por um longo per\u00edodo sem falhas.<\/p><ul data-start=\"424\" data-end=\"1721\"><li class=\"\" data-start=\"424\" data-end=\"610\"><p class=\"\" data-start=\"426\" data-end=\"610\"><strong data-start=\"426\" data-end=\"445\">Tens\u00e3o de alimenta\u00e7\u00e3o:<\/strong> A tens\u00e3o da fonte de alimenta\u00e7\u00e3o deve estar dentro da faixa de tens\u00e3o operacional nominal do atuador. Sobretens\u00e3o ou subtens\u00e3o podem reduzir a vida \u00fatil do atuador.<\/p><\/li><li class=\"\" data-start=\"614\" data-end=\"840\"><p class=\"\" data-start=\"616\" data-end=\"840\"><strong data-start=\"616\" data-end=\"635\">Corrente de alimenta\u00e7\u00e3o:<\/strong> A corrente de partida do motor \u00e9 significativamente maior que a corrente nominal. Para garantir uma opera\u00e7\u00e3o confi\u00e1vel, utilize uma fonte de alimenta\u00e7\u00e3o capaz de fornecer pelo menos 3 vezes a corrente nominal do atuador.<\/p><\/li><li class=\"\" data-start=\"842\" data-end=\"1035\"><p class=\"\" data-start=\"844\" data-end=\"1035\"><strong data-start=\"844\" data-end=\"860\">Temperatura:<\/strong> Certifique-se de que o atuador opere dentro da sua faixa de temperatura nominal. O uso do atuador fora dessa faixa pode resultar em desempenho insatisfat\u00f3rio, redu\u00e7\u00e3o da vida \u00fatil e eventual falha.<\/p><\/li><li class=\"\" data-start=\"1037\" data-end=\"1504\"><p class=\"\" data-start=\"1039\" data-end=\"1504\"><strong data-start=\"1039\" data-end=\"1055\">Ambiente:<\/strong> O atuador tipo interruptor DCL possui classifica\u00e7\u00e3o de prote\u00e7\u00e3o IP67 contra intemp\u00e9ries, sendo adequado para aplica\u00e7\u00f5es internas e externas. Ele oferece um certo grau de prote\u00e7\u00e3o contra chuva e respingos de \u00e1gua, ajudando a prolongar a vida \u00fatil do atuador, protegendo-o da chuva, neve, gelo e raios UV (luz solar). No entanto, em ambientes altamente corrosivos, os componentes eletr\u00f4nicos podem falhar prematuramente. Atuadores n\u00e3o \u00e0 prova de explos\u00e3o n\u00e3o devem ser usados em ambientes explosivos.<\/p><\/li><li class=\"\" data-start=\"1506\" data-end=\"1721\"><p class=\"\" data-start=\"1508\" data-end=\"1721\"><strong data-start=\"1508\" data-end=\"1523\">Ciclo de trabalho:<\/strong> O atuador tipo interruptor DCL possui um ciclo de trabalho de 70% (42 segundos de opera\u00e7\u00e3o por minuto, seguidos por 18 segundos de repouso). Exceder esse ciclo de trabalho pode fazer com que o motor entre em prote\u00e7\u00e3o t\u00e9rmica.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0273976 elementor-widget elementor-widget-heading\" data-id=\"0273976\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Verifique a fia\u00e7\u00e3o do atuador.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9df2216 elementor-widget elementor-widget-text-editor\" data-id=\"9df2216\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"45\" data-end=\"186\">Certifique-se de que o atuador esteja conectado corretamente de acordo com o diagrama de fia\u00e7\u00e3o fornecido pelo fabricante. Siga estas etapas para verificar a fia\u00e7\u00e3o:<\/p><ol data-start=\"188\" data-end=\"1007\"><li class=\"\" data-start=\"188\" data-end=\"325\"><p class=\"\" data-start=\"191\" data-end=\"209\"><strong data-start=\"191\" data-end=\"208\">Fonte de energia:<\/strong><\/p><ul data-start=\"213\" data-end=\"325\"><li class=\"\" data-start=\"213\" data-end=\"321\"><p class=\"\" data-start=\"215\" data-end=\"321\">Verifique as conex\u00f5es da fonte de alimenta\u00e7\u00e3o para garantir que correspondam \u00e0 tens\u00e3o e corrente de entrada exigidas pelo atuador.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"326\" data-end=\"504\"><p class=\"\" data-start=\"329\" data-end=\"353\"><strong data-start=\"329\" data-end=\"353\">Conex\u00f5es de controle:<\/strong><\/p><ul data-start=\"357\" data-end=\"504\"><li class=\"\" data-start=\"357\" data-end=\"504\"><p class=\"\" data-start=\"359\" data-end=\"504\">Verifique se as conex\u00f5es de controle de entrada e sa\u00edda est\u00e3o firmemente fixadas e na configura\u00e7\u00e3o correta, conforme o diagrama de fia\u00e7\u00e3o do atuador.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"506\" data-end=\"707\"><p class=\"\" data-start=\"509\" data-end=\"527\"><strong data-start=\"509\" data-end=\"527\">Fia\u00e7\u00e3o de sinal:<\/strong><\/p><ul data-start=\"531\" data-end=\"707\"><li class=\"\" data-start=\"531\" data-end=\"639\"><p class=\"\" data-start=\"533\" data-end=\"639\">Verifique a fia\u00e7\u00e3o em busca de sinais de controle, como 4-20mA ou 0-10V, dependendo das especifica\u00e7\u00f5es do atuador.<\/p><\/li><li class=\"\" data-start=\"643\" data-end=\"707\"><p class=\"\" data-start=\"645\" data-end=\"707\">Confirme se n\u00e3o h\u00e1 conex\u00f5es soltas ou curto-circuitos.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"709\" data-end=\"823\"><p class=\"\" data-start=\"712\" data-end=\"726\"><strong data-start=\"712\" data-end=\"726\">Aterramento:<\/strong><\/p><ul data-start=\"730\" data-end=\"823\"><li class=\"\" data-start=\"730\" data-end=\"823\"><p class=\"\" data-start=\"732\" data-end=\"823\">Certifique-se de que o atuador esteja devidamente aterrado para evitar interfer\u00eancias el\u00e9tricas ou danos.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"825\" data-end=\"1007\"><p class=\"\" data-start=\"828\" data-end=\"863\"><strong data-start=\"828\" data-end=\"863\">Conex\u00f5es com outros equipamentos:<\/strong><\/p><ul data-start=\"867\" data-end=\"1007\"><li class=\"\" data-start=\"867\" data-end=\"1007\"><p class=\"\" data-start=\"869\" data-end=\"1007\">Se o atuador estiver conectado a outros dispositivos, certifique-se de que essas conex\u00f5es tamb\u00e9m estejam corretas e n\u00e3o causem interfer\u00eancia ou problemas de energia.<\/p><\/li><\/ul><\/li><\/ol><p class=\"\" data-start=\"1009\" data-end=\"1155\">Se a fia\u00e7\u00e3o parecer correta, mas o atuador ainda estiver apresentando mau funcionamento, pode ser necess\u00e1rio realizar mais testes ou solicitar a assist\u00eancia de um t\u00e9cnico.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-84857ae e-flex e-con-boxed e-con e-parent\" data-id=\"84857ae\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cf23cb0 elementor-widget elementor-widget-template\" data-id=\"cf23cb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"template.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-template\">\n\t\t\t\t\t<div data-elementor-type=\"section\" data-elementor-id=\"10969\" class=\"elementor elementor-10969\" data-elementor-post-type=\"elementor_library\">\n\t\t\t<div class=\"elementor-element elementor-element-d642a8e e-flex e-con-boxed e-con e-parent\" data-id=\"d642a8e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-4dcc388 e-con-full e-flex e-con e-child\" data-id=\"4dcc388\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09f4232 elementor-widget elementor-widget-heading\" data-id=\"09f4232\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">A - Com 2 sa\u00eddas de sinal de posi\u00e7\u00e3o final activas<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-daf3293 elementor-widget elementor-widget-image\" data-id=\"daf3293\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"341\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-a.webp\" class=\"attachment-full size-full wp-image-4860\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668A\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14e5438 elementor-widget elementor-widget-text-editor\" data-id=\"14e5438\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Controlo do atuador para abrir ou fechar com K<\/li><li>O terminal de sa\u00edda da posi\u00e7\u00e3o final OPEN\/CLOSE enviar\u00e1 o evento como um sinal ativo de 220VAC quando a posi\u00e7\u00e3o final for atingida.<\/li><\/ul><p>\u00a0<\/p><p><strong>Detalhes de liga\u00e7\u00e3o:<\/strong><\/p><ol><li>Liga\u00e7\u00e3o do neutro da alimenta\u00e7\u00e3o AC85-220V a P1.<\/li><li>Comutar a linha AC85-220V para CLOSE(P2) para fechar a v\u00e1lvula<\/li><li>Comutar a linha AC85-220V para OPEN(P3) para abrir a v\u00e1lvula.<\/li><li>P5 \u00e9 o terminal de posi\u00e7\u00e3o final ABERTO que produzir\u00e1 uma fonte de AC220V que pode ser utilizada para acionar uma luz de indica\u00e7\u00e3o quando o atuador atingir a posi\u00e7\u00e3o final de aberto.<\/li><li>P6 \u00e9 o terminal de posi\u00e7\u00e3o final ABERTO que produzir\u00e1 uma fonte de AC220V que pode ser utilizada para acionar uma luz de indica\u00e7\u00e3o quando o atuador atingir a posi\u00e7\u00e3o final de fecho.<\/li><li>Ligar a terra a P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f1a67a7 e-con-full e-flex e-con e-child\" data-id=\"f1a67a7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a942089 elementor-widget elementor-widget-heading\" data-id=\"a942089\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">B - Com 2 interruptores passivos de posi\u00e7\u00e3o final<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-766f845 elementor-widget elementor-widget-image\" data-id=\"766f845\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"348\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-b.webp\" class=\"attachment-full size-full wp-image-4858\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668B\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-799d994 elementor-widget elementor-widget-text-editor\" data-id=\"799d994\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Controlo do atuador para abrir ou fechar com K<\/li><li>O terminal de sa\u00edda da posi\u00e7\u00e3o final OPEN\/CLOSE enviar\u00e1 o evento como uma forma de sinal passivo quando a posi\u00e7\u00e3o final for atingida.<\/li><\/ul><p>\u00a0<\/p><p><strong>Detalhes de liga\u00e7\u00e3o:<\/strong><\/p><ol><li>Liga\u00e7\u00e3o do neutro da alimenta\u00e7\u00e3o AC85-220V a P1.<\/li><li>Comutar a linha AC85-220V para CLOSE(P2) para fechar a v\u00e1lvula<\/li><li>Comutar a linha AC85-220V para OPEN(P3) para abrir a v\u00e1lvula.<\/li><li>P4 \u00e9 o COM para o sinal de contacto passivo da posi\u00e7\u00e3o final ABERTO\/FECHADO que est\u00e1 normalmente ligado ao sinal GND.<\/li><li>P5 \u00e9 o terminal de posi\u00e7\u00e3o final ABERTO que ser\u00e1 ligado a COM quando o atuador atingir a posi\u00e7\u00e3o final de aberto.<\/li><li>P6 \u00e9 o terminal FECHADO de posi\u00e7\u00e3o final que ser\u00e1 ligado a COM quando o atuador atingir a posi\u00e7\u00e3o final de fecho.<\/li><li>Ligar a terra a P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-738bf4f e-con-full e-flex e-con e-child\" data-id=\"738bf4f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5a73aaa elementor-widget elementor-widget-heading\" data-id=\"5a73aaa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">G - Motor DC com 2 interruptores de posi\u00e7\u00e3o final<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c393f4 elementor-widget elementor-widget-image\" data-id=\"8c393f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"391\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-g.webp\" class=\"attachment-full size-full wp-image-4853\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668G\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a35d4cf elementor-widget elementor-widget-text-editor\" data-id=\"a35d4cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Atuador de controlo para abrir ou fechar atrav\u00e9s da dire\u00e7\u00e3o da alimenta\u00e7\u00e3o entre os terminais 1 e 2<\/li><li>O terminal de sa\u00edda da posi\u00e7\u00e3o final OPEN\/CLOSE enviar\u00e1 o evento como uma forma de sinal passivo quando a posi\u00e7\u00e3o final for atingida.<\/li><\/ul><p>\u00a0<\/p><p><strong>Detalhes de liga\u00e7\u00e3o:<\/strong><\/p><ol><li>Ligar DC24V+ a P1 e DC24V- a P2 para fechar a v\u00e1lvula.<\/li><li>Ligar DC24V+ a P2 e DC24V- a P1 para fechar a v\u00e1lvula.<\/li><li>P3 \u00e9 o COM para o sinal de contacto passivo da posi\u00e7\u00e3o final ABERTO\/FECHADO que est\u00e1 normalmente ligado ao sinal GND.<\/li><li>P4 \u00e9 o terminal de posi\u00e7\u00e3o final ABERTO que ser\u00e1 ligado a COM quando o atuador atingir a posi\u00e7\u00e3o final de aberto.<\/li><li>P5 \u00e9 o terminal FECHADO de posi\u00e7\u00e3o final que ser\u00e1 ligado a COM quando o atuador atingir a posi\u00e7\u00e3o final de fecho.<\/li><li>Ligar a terra a P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ff65758 e-con-full e-flex e-con e-parent\" data-id=\"ff65758\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-d5dc048 e-con-full e-flex e-con e-child\" data-id=\"d5dc048\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-527200f elementor-widget elementor-widget-text-editor\" data-id=\"527200f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nota\uff1a<\/p><ul><li>O circuito dentro da caixa tracejada \u00e9 o circuito interno do atuador. Enquanto o circuito exterior \u00e9 uma demonstra\u00e7\u00e3o da liga\u00e7\u00e3o el\u00e9ctrica para utilizar o atuador.<\/li><li>Se tiver outros requisitos espec\u00edficos sobre o circuito de liga\u00e7\u00e3o, n\u00e3o hesite em contactar o nosso apoio t\u00e9cnico.\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-002d845 elementor-widget elementor-widget-text-editor\" data-id=\"002d845\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ao realizar a resolu\u00e7\u00e3o de problemas no local, n\u00e3o hesite em contatar imediatamente nossa equipe de assist\u00eancia t\u00e9cnica para obter ajuda no diagn\u00f3stico e na solu\u00e7\u00e3o do problema. <br \/>Telefone para contato: 13026331611 (Sr. Chen)<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Este guia aplica-se aos atuadores da S\u00e9rie Ultracompacta DCL, com os seguintes modelos: DCL-02A, DCL-02B e DCL-02G. Problemas Comuns e M\u00e9todos de Solu\u00e7\u00e3o de Problemas: Problema: Poss\u00edveis Causas: O atuador n\u00e3o abre ou fecha na inicializa\u00e7\u00e3o. M\u00e9todos de Solu\u00e7\u00e3o de Problemas: 1. Fia\u00e7\u00e3o incorreta: Verifique a fia\u00e7\u00e3o de acordo com o diagrama de fia\u00e7\u00e3o do atuador. 2. Alimenta\u00e7\u00e3o incorreta: Certifique-se de que [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[103],"tags":[53],"class_list":["post-6033","post","type-post","status-publish","format-standard","hentry","category-mr-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/posts\/6033","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/comments?post=6033"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/posts\/6033\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/media?parent=6033"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/categories?post=6033"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/pt_pt\/wp-json\/wp\/v2\/tags?post=6033"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}