{"id":6034,"date":"2023-08-03T20:40:54","date_gmt":"2023-08-03T12:40:54","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6034"},"modified":"2025-03-27T09:36:11","modified_gmt":"2025-03-27T09:36:11","slug":"dcl-02-modulating-actuator","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/pt\/apoiar\/senhor-atuador\/dcl-02-modulating-actuator","title":{"rendered":"Common faults &amp; troubleshooting for DCL-02 modulating actuators"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6034\" class=\"elementor elementor-6034\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4d0a73a e-con-full e-flex e-con e-parent\" data-id=\"4d0a73a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-074db40 e-con-full e-flex e-con e-child\" data-id=\"074db40\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c0eba31 elementor-widget elementor-widget-text-editor\" data-id=\"c0eba31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Este guia aplica-se aos atuadores moduladores ultracompactos da DCL, modelo a seguir:<\/p><p>DCL-02E<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-baf5aaf elementor-widget elementor-widget-image\" data-id=\"baf5aaf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-02-valve.webp\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4622d9 elementor-widget elementor-widget-heading\" data-id=\"b4622d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Falhas comuns e m\u00e9todos de resolu\u00e7\u00e3o de problemas<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e06e825 elementor-widget elementor-widget-text-editor\" data-id=\"e06e825\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>\u00a0<\/h3><table><thead><tr><th><strong>Falta<\/strong><\/th><th><strong>Poss\u00edvel causa<\/strong><\/th><th><strong>M\u00e9todo de resolu\u00e7\u00e3o de problemas<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>O atuador n\u00e3o abre nem fecha na inicializa\u00e7\u00e3o.<\/strong><\/td><td>1. Fia\u00e7\u00e3o incorreta<\/td><td>Verifique a fia\u00e7\u00e3o de acordo com o diagrama de fia\u00e7\u00e3o do atuador para confirmar se est\u00e1 correta.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Fonte de alimenta\u00e7\u00e3o incorreta<\/td><td>Certifique-se de que a tens\u00e3o de sa\u00edda da fonte de alimenta\u00e7\u00e3o esteja dentro de \u00b110% da tens\u00e3o nominal do atuador e que a corrente seja 3 vezes a corrente nominal do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Interruptor ou rel\u00e9 de controle anormal<\/td><td>Me\u00e7a a tens\u00e3o de entrada no terminal de controle do interruptor do atuador com um mult\u00edmetro para garantir que ela corresponda ao valor esperado.<\/td><\/tr><tr><td>\u00a0<\/td><td>4. Incompatibilidade do sistema de controle<\/td><td>Utilize um interruptor mec\u00e2nico para testar a funcionalidade do atuador. Se o atuador funcionar corretamente, verifique a l\u00f3gica de sa\u00edda do sistema de controle.<\/td><\/tr><tr><td>\u00a0<\/td><td>5. M\u00faltiplos atuadores ou conex\u00e3o paralela de atuadores com outros dispositivos<\/td><td>Os atuadores do tipo interruptor come\u00e7am com um capacitor. A conex\u00e3o em paralelo com outros dispositivos afetar\u00e1 o valor do capacitor. Os atuadores do tipo interruptor devem ser usados apenas com controle individual, n\u00e3o com controle em paralelo.<\/td><\/tr><tr><td><strong>O atuador s\u00f3 pode abrir ou fechar.<\/strong><\/td><td>1. Fia\u00e7\u00e3o incorreta<\/td><td>1. Utilize um interruptor mec\u00e2nico para testar a funcionalidade do atuador. Se funcionar corretamente, verifique a l\u00f3gica de sa\u00edda do sistema de controle.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. Verifique a fia\u00e7\u00e3o de acordo com o diagrama de fia\u00e7\u00e3o do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Configura\u00e7\u00e3o incorreta da c\u00e2mera de abertura\/fechamento total<\/td><td>Consulte \u201cComo ajustar v\u00e1lvulas el\u00e9tricas do tipo interruptor\u201d para o posicionamento correto da came.<\/td><\/tr><tr><td><strong>O atuador para no meio do curso.<\/strong><\/td><td>1. Travamento da v\u00e1lvula<\/td><td>Verifique se a v\u00e1lvula est\u00e1 emperrada, remova o bloqueio e tente novamente ap\u00f3s o resfriamento da prote\u00e7\u00e3o contra sobrecarga do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Part\u00edculas s\u00f3lidas no fluido causando travamento da v\u00e1lvula<\/td><td>Verifique se h\u00e1 part\u00edculas s\u00f3lidas no fluido causando o travamento da v\u00e1lvula, remova o bloqueio e tente novamente ap\u00f3s o resfriamento da prote\u00e7\u00e3o contra sobrecarga do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Configura\u00e7\u00e3o incorreta do bloco de parada de abertura\/fechamento total<\/td><td>Consulte a se\u00e7\u00e3o \u201cComo configurar v\u00e1lvulas el\u00e9tricas do tipo interruptor\u201d para ajustar corretamente a posi\u00e7\u00e3o do bloco de parada.<\/td><\/tr><tr><td><strong>N\u00e3o \u00e9 poss\u00edvel girar o atuador usando a alavanca.<\/strong><\/td><td>1. Part\u00edculas s\u00f3lidas no fluido causando o travamento da v\u00e1lvula<\/td><td>Verifique se part\u00edculas s\u00f3lidas est\u00e3o causando o travamento da v\u00e1lvula, remova o bloqueio e tente novamente ap\u00f3s o resfriamento da prote\u00e7\u00e3o contra sobrecarga do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. A v\u00e1lvula est\u00e1 presa<\/td><td>Verifique se a v\u00e1lvula est\u00e1 presa, remova o bloqueio e tente novamente ap\u00f3s o resfriamento da prote\u00e7\u00e3o contra sobrecarga do atuador.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Mecanismo de desacelera\u00e7\u00e3o do atuador danificado<\/td><td>Remova o atuador da v\u00e1lvula e gire a alavanca. Se ela n\u00e3o girar, substitua-a por um atuador novo.<\/td><\/tr><tr><td><strong>Sem sa\u00edda do sinal de feedback de posi\u00e7\u00e3o<\/strong><\/td><td>1. Fia\u00e7\u00e3o incorreta do interruptor<\/td><td>Verifique a fia\u00e7\u00e3o de acordo com o diagrama de fia\u00e7\u00e3o do atuador para confirmar se est\u00e1 correta.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Configura\u00e7\u00e3o incorreta da c\u00e2mera de abertura\/fechamento total<\/td><td>Consulte a se\u00e7\u00e3o \u201cComo ajustar v\u00e1lvulas el\u00e9tricas do tipo interruptor\u201d para ajustar corretamente a posi\u00e7\u00e3o da came.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Sobrecorrente causando falha no interruptor de feedback de posi\u00e7\u00e3o<\/td><td>1. Consulte \u201cComo configurar v\u00e1lvulas el\u00e9tricas do tipo interruptor\u201d para verificar se a came de abertura total\/fechamento total est\u00e1 pressionando corretamente o interruptor de feedback de posi\u00e7\u00e3o.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. Verifique se o circuito de feedback de posi\u00e7\u00e3o est\u00e1 conectado.<\/td><\/tr><\/tbody><\/table><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6802156 elementor-widget elementor-widget-heading\" data-id=\"6802156\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2. Verificar as condi\u00e7\u00f5es de compatibilidade da aplica\u00e7\u00e3o<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be9bb57 elementor-widget elementor-widget-text-editor\" data-id=\"be9bb57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5234\" data-end=\"5479\">Os atuadores el\u00e9tricos podem falhar se forem usados incorretamente ou em condi\u00e7\u00f5es de aplica\u00e7\u00e3o inadequadas. Garantir que o atuador opere dentro das especifica\u00e7\u00f5es definidas na ficha t\u00e9cnica do produto ajudar\u00e1 a assegurar um funcionamento sem problemas a longo prazo.<\/p><ul data-start=\"5481\" data-end=\"6708\" data-is-only-node=\"\"><li class=\"\" data-start=\"5481\" data-end=\"5667\"><p class=\"\" data-start=\"5483\" data-end=\"5667\"><strong data-start=\"5483\" data-end=\"5507\">Tens\u00e3o da fonte de alimenta\u00e7\u00e3o<\/strong>A tens\u00e3o da fonte de alimenta\u00e7\u00e3o deve estar dentro da faixa de tens\u00e3o operacional nominal do atuador. Sobretens\u00e3o ou subtens\u00e3o podem reduzir a vida \u00fatil do atuador.<\/p><\/li><li class=\"\" data-start=\"5671\" data-end=\"5866\"><p class=\"\" data-start=\"5673\" data-end=\"5866\"><strong data-start=\"5673\" data-end=\"5697\">Corrente da fonte de alimenta\u00e7\u00e3o<\/strong>Como a corrente de partida do motor \u00e9 muito maior que a corrente nominal, certifique-se de que a fonte de alimenta\u00e7\u00e3o tenha pelo menos 3 vezes a capacidade de corrente nominal do atuador.<\/p><\/li><li class=\"\" data-start=\"5868\" data-end=\"6082\"><p class=\"\" data-start=\"5870\" data-end=\"6082\"><strong data-start=\"5870\" data-end=\"5885\">Temperatura<\/strong>Certifique-se de que o atuador opere dentro da sua faixa de temperatura nominal. O uso do atuador fora da faixa de temperatura nominal pode levar a mau funcionamento ou redu\u00e7\u00e3o da vida \u00fatil, causando, em \u00faltima inst\u00e2ncia, falha.<\/p><\/li><li class=\"\" data-start=\"6084\" data-end=\"6498\"><p class=\"\" data-start=\"6086\" data-end=\"6498\"><strong data-start=\"6086\" data-end=\"6101\">Ambiente<\/strong>Os atuadores tipo interruptor da DCL possuem classifica\u00e7\u00e3o IP67 de resist\u00eancia \u00e0s intemp\u00e9ries, sendo adequados para uso interno e externo. Eles oferecem alguma prote\u00e7\u00e3o contra chuva, respingos de \u00e1gua e raios UV (luz solar), o que normalmente prolonga a vida \u00fatil do produto. No entanto, ambientes altamente corrosivos podem causar falhas prematuras dos componentes eletr\u00f4nicos. N\u00e3o utilize atuadores da s\u00e9rie n\u00e3o \u00e0 prova de explos\u00e3o em ambientes perigosos.<\/p><\/li><li class=\"\" data-start=\"6500\" data-end=\"6708\"><p class=\"\" data-start=\"6502\" data-end=\"6708\"><strong data-start=\"6502\" data-end=\"6516\">Ciclo de trabalho<\/strong>O atuador tipo interruptor DCL possui um ciclo de trabalho de 70% (42 segundos de opera\u00e7\u00e3o seguidos por 18 segundos de repouso). Exceder esse ciclo de trabalho pode fazer com que o motor entre no modo de prote\u00e7\u00e3o t\u00e9rmica.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-823dd6a elementor-widget elementor-widget-heading\" data-id=\"823dd6a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Verifique a fia\u00e7\u00e3o do atuador.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-32ec269 elementor-widget elementor-widget-text-editor\" data-id=\"32ec269\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"41\" data-end=\"104\">Para garantir o funcionamento correto do atuador, siga estes passos:<\/p><ol data-start=\"106\" data-end=\"1403\"><li class=\"\" data-start=\"106\" data-end=\"331\"><p class=\"\" data-start=\"109\" data-end=\"156\"><strong data-start=\"109\" data-end=\"156\">Verifique a fia\u00e7\u00e3o de acordo com o diagrama:<\/strong><\/p><ul data-start=\"160\" data-end=\"331\"><li class=\"\" data-start=\"160\" data-end=\"237\"><p class=\"\" data-start=\"162\" data-end=\"237\">Verifique novamente a fia\u00e7\u00e3o para garantir que ela corresponda ao diagrama de fia\u00e7\u00e3o do atuador.<\/p><\/li><li class=\"\" data-start=\"241\" data-end=\"327\"><p class=\"\" data-start=\"243\" data-end=\"327\">Confirme se todas as conex\u00f5es est\u00e3o seguras e se nenhum fio est\u00e1 solto ou desconectado.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"332\" data-end=\"558\"><p class=\"\" data-start=\"335\" data-end=\"366\"><strong data-start=\"335\" data-end=\"366\">Verifique a polaridade correta:<\/strong><\/p><ul data-start=\"370\" data-end=\"558\"><li class=\"\" data-start=\"370\" data-end=\"483\"><p class=\"\" data-start=\"372\" data-end=\"483\">Certifique-se de que os terminais positivo e negativo da fonte de alimenta\u00e7\u00e3o estejam conectados aos terminais corretos do atuador.<\/p><\/li><li class=\"\" data-start=\"487\" data-end=\"558\"><p class=\"\" data-start=\"489\" data-end=\"558\">A polaridade incorreta pode causar mau funcionamento ou danos ao atuador.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"560\" data-end=\"787\"><p class=\"\" data-start=\"563\" data-end=\"601\"><strong data-start=\"563\" data-end=\"601\">Inspecione a fia\u00e7\u00e3o do sinal de controle:<\/strong><\/p><ul data-start=\"605\" data-end=\"787\"><li class=\"\" data-start=\"605\" data-end=\"687\"><p class=\"\" data-start=\"607\" data-end=\"687\">Verifique a fia\u00e7\u00e3o dos sinais de controle (ex.: sinal de entrada, sinal de feedback).<\/p><\/li><li class=\"\" data-start=\"691\" data-end=\"787\"><p class=\"\" data-start=\"693\" data-end=\"787\">Certifique-se de que os fios de sinal estejam conectados corretamente e sem curtos-circuitos ou interrup\u00e7\u00f5es.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"789\" data-end=\"1011\"><p class=\"\" data-start=\"792\" data-end=\"816\"><strong data-start=\"792\" data-end=\"816\">Verificar aterramento:<\/strong><\/p><ul data-start=\"820\" data-end=\"1011\"><li class=\"\" data-start=\"820\" data-end=\"929\"><p class=\"\" data-start=\"822\" data-end=\"929\">Assegure-se de que o atuador esteja devidamente aterrado para evitar interfer\u00eancias de ru\u00eddo el\u00e9trico ou poss\u00edveis curtos-circuitos.<\/p><\/li><li class=\"\" data-start=\"933\" data-end=\"1011\"><p class=\"\" data-start=\"935\" data-end=\"1011\">Uma liga\u00e7\u00e3o \u00e0 terra defeituosa pode causar comportamento err\u00e1tico ou falha de funcionamento.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"1013\" data-end=\"1212\"><p class=\"\" data-start=\"1016\" data-end=\"1063\"><strong data-start=\"1016\" data-end=\"1063\">Confirme a fia\u00e7\u00e3o dos componentes externos:<\/strong><\/p><ul data-start=\"1067\" data-end=\"1212\"><li class=\"\" data-start=\"1067\" data-end=\"1208\"><p class=\"\" data-start=\"1069\" data-end=\"1208\">Se dispositivos externos, como interruptores de limite, sensores ou m\u00f3dulos de controle adicionais, estiverem conectados, verifique se a fia\u00e7\u00e3o est\u00e1 segura e correta.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"1213\" data-end=\"1403\"><p class=\"\" data-start=\"1216\" data-end=\"1245\"><strong data-start=\"1216\" data-end=\"1245\">Teste o circuito de controle:<\/strong><\/p><ul data-start=\"1249\" data-end=\"1403\"><li class=\"\" data-start=\"1249\" data-end=\"1351\"><p class=\"\" data-start=\"1251\" data-end=\"1351\">Utilize um mult\u00edmetro para verificar o circuito de controle, incluindo a tens\u00e3o de entrada nos terminais de controle.<\/p><\/li><li class=\"\" data-start=\"1355\" data-end=\"1403\"><p class=\"\" data-start=\"1357\" data-end=\"1403\">Confirme se a faixa de tens\u00e3o esperada est\u00e1 presente.<\/p><\/li><\/ul><\/li><\/ol><p class=\"\" data-start=\"1405\" data-end=\"1634\">Ap\u00f3s confirmar se a fia\u00e7\u00e3o est\u00e1 correta, prossiga com o teste do atuador para garantir seu funcionamento adequado. Se algum problema persistir ap\u00f3s a verifica\u00e7\u00e3o da fia\u00e7\u00e3o, pode ser necess\u00e1rio inspecionar mais detalhadamente os componentes internos do atuador.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-422047d elementor-widget elementor-widget-template\" data-id=\"422047d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"template.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-template\">\n\t\t\t\t\t<div data-elementor-type=\"section\" data-elementor-id=\"10970\" class=\"elementor elementor-10970\" data-elementor-post-type=\"elementor_library\">\n\t\t\t<div class=\"elementor-element elementor-element-19a6173 e-flex e-con-boxed e-con e-parent\" data-id=\"19a6173\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-984e463 e-con-full e-flex e-con e-child\" data-id=\"984e463\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d08c8ca elementor-widget elementor-widget-heading\" data-id=\"d08c8ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">E - Modula\u00e7\u00e3o com uma unidade de controle<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e3dcbb5 elementor-widget elementor-widget-image\" data-id=\"e3dcbb5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"400\" height=\"330\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-e.webp\" class=\"attachment-full size-full wp-image-4857\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668E\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4396a8e elementor-widget elementor-widget-text-editor\" data-id=\"4396a8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Entrada: 4~20mA \/ 0~10V<\/li><li>Sa\u00edda: 4~20mA \/ 0~10V<\/li><\/ul><p>\u00a0<\/p><p><strong>Detalhes de conex\u00e3o:<\/strong><\/p><ol><li>Conecte a linha de alimenta\u00e7\u00e3o AC85-220V ao fio L e o neutro ao fio N.<\/li><li>Conectar a fonte de sinal de entrada de 4-20mA\/2-10V do sistema de controle \u00e0 entrada -\/+.<\/li><li>Conecte a sa\u00edda -\/+ ao sistema para enviar a posi\u00e7\u00e3o da v\u00e1lvula em tempo real.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ff65758 e-con-full e-flex e-con e-parent\" data-id=\"ff65758\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-d5dc048 e-con-full e-flex e-con e-child\" data-id=\"d5dc048\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-527200f elementor-widget elementor-widget-text-editor\" data-id=\"527200f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Observa\u00e7\u00e3o:<\/p><ul><li>O circuito dentro da caixa tracejada \u00e9 o circuito interno do atuador. J\u00e1 o circuito externo demonstra a conex\u00e3o el\u00e9trica para utiliza\u00e7\u00e3o do atuador.<\/li><li>Caso tenha outros requisitos espec\u00edficos sobre a conex\u00e3o do circuito, n\u00e3o hesite em contatar nosso suporte t\u00e9cnico.\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-09f9fde elementor-widget elementor-widget-text-editor\" data-id=\"09f9fde\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ao solucionar problemas no local, voc\u00ea pode entrar em contato imediatamente com nossa equipe de assist\u00eancia t\u00e9cnica para que juntos possamos analisar o problema e determinar a solu\u00e7\u00e3o.<\/p><p>N\u00famero de contato: 13026331611 (Sr. Chen)<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>This guide applies to the DCL ultra small modulating actuators, model as follows: DCL-02E Common Faults and Troubleshooting Methods \u00a0 Fault Possible Cause Troubleshooting Method Actuator will not open or close at startup 1. Incorrect wiring Check the wiring according to the actuator wiring diagram to confirm it is correct. \u00a0 2. Incorrect power supply [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[103],"tags":[53],"class_list":["post-6034","post","type-post","status-publish","format-standard","hentry","category-mr-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/pt\/wp-json\/wp\/v2\/posts\/6034","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/pt\/wp-json\/wp\/v2\/comments?post=6034"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/pt\/wp-json\/wp\/v2\/posts\/6034\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/pt\/wp-json\/wp\/v2\/media?parent=6034"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/pt\/wp-json\/wp\/v2\/categories?post=6034"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/pt\/wp-json\/wp\/v2\/tags?post=6034"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}