{"id":6033,"date":"2023-08-03T20:44:54","date_gmt":"2023-08-03T12:44:54","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6033"},"modified":"2025-03-27T09:47:56","modified_gmt":"2025-03-27T09:47:56","slug":"dcl-02-on-off-actuator","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/nl_nl\/ondersteuning\/meneer-actuator\/dcl-02-aan-uit-actuator","title":{"rendered":"Veelvoorkomende storingen en probleemoplossing voor DCL-02 aan\/uit-actuatoren"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6033\" class=\"elementor elementor-6033\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-23bbd22 e-con-full e-flex e-con e-parent\" data-id=\"23bbd22\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-add184b e-con-full e-flex e-con e-child\" data-id=\"add184b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ec8fa0c elementor-widget elementor-widget-text-editor\" data-id=\"ec8fa0c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"0\" data-end=\"92\">Deze handleiding is van toepassing op de DCL Ultra-Small Series actuatoren, met de volgende modellen:<\/p><ul data-start=\"94\" data-end=\"123\"><li class=\"\" data-start=\"94\" data-end=\"103\"><p class=\"\" data-start=\"96\" data-end=\"103\">DCL-02A<\/p><\/li><li class=\"\" data-start=\"104\" data-end=\"113\"><p class=\"\" data-start=\"106\" data-end=\"113\">DCL-02B<\/p><\/li><li class=\"\" data-start=\"114\" data-end=\"123\"><p class=\"\" data-start=\"116\" data-end=\"123\">DCL-02G<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69c14e5 elementor-widget elementor-widget-image\" data-id=\"69c14e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"176\" height=\"399\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/dcl-02-valve.webp\" class=\"attachment-full size-full wp-image-4861\" alt=\"DCL-02 producten | DCL-02 Actuatorklep\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b43d346 elementor-widget elementor-widget-heading\" data-id=\"b43d346\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Veelvoorkomende fouten en methoden voor het oplossen ervan<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1d44fb elementor-widget elementor-widget-text-editor\" data-id=\"e1d44fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0<\/p><table><thead><tr><th><strong>Schuld<\/strong><\/th><th><strong>Mogelijke oorzaken<\/strong><\/th><th><strong>Probleemoplossingsmethoden<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>De actuator opent of sluit niet bij de eerste opstart.<\/strong><\/td><td>1. Onjuiste bedrading<\/td><td>Controleer de bedrading aan de hand van het bedradingsschema van de actuator.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Onjuiste voeding<\/td><td>Zorg ervoor dat de voedingsspanning binnen \u00b110% van de nominale spanning van de actuator ligt en dat de stroom 3 keer de nominale stroom bedraagt.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Defecte bedieningsschakelaar of relais<\/td><td>Meet de ingangsspanning bij de stuuraansluiting van de actuator met een multimeter om te controleren of deze aan de verwachtingen voldoet.<\/td><\/tr><tr><td>\u00a0<\/td><td>4. Mismatch in het besturingssysteem<\/td><td>Test de actuator met een mechanische schakelaar. Als deze normaal functioneert, controleer dan de uitgangslogica van het besturingssysteem.<\/td><\/tr><tr><td>\u00a0<\/td><td>5. Meerdere actuatoren of actuatoren en andere apparaten parallel geschakeld<\/td><td>Schakelaaractuatoren moeten gebruikmaken van enkelvoudige stroomgeleiding en mogen niet parallel worden aangesloten, aangezien dit de opstartcondensator be\u00efnvloedt.<\/td><\/tr><tr><td><strong>De actuator kan alleen openen of sluiten.<\/strong><\/td><td>1. Onjuiste bedrading<\/td><td>Controleer de bedrading aan de hand van het bedradingsschema van de actuator.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Onjuiste instelling van de nok voor volledig openen\/sluiten.<\/td><td>Raadpleeg de handleiding &quot;Elektrische schakelventielen instellen&quot; en stel de nokken correct in.<\/td><\/tr><tr><td><strong>De actuator stopt halverwege de beweging.<\/strong><\/td><td>1. Klep vastgelopen<\/td><td>Controleer of de klep verstopt is. Verwijder eventuele obstructies en probeer het opnieuw nadat de overbelastingsbeveiliging van de actuator is afgekoeld.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Vast materiaal in de vloeistof veroorzaakt klepblokkering<\/td><td>Controleer de vloeistof op vaste deeltjes die de klep blokkeren. Verwijder de blokkade en probeer het opnieuw nadat de overbelastingsbeveiliging van de actuator is afgekoeld.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Onjuiste volledig open\/gesloten stopstand<\/td><td>Raadpleeg de handleiding &quot;Elektrische schakelventielen instellen&quot; en stel de stopstanden correct in.<\/td><\/tr><tr><td><strong>Het lukt me niet om de actuator te draaien met de hendel.<\/strong><\/td><td>1. Vast materiaal in de vloeistof waardoor de klep vastloopt<\/td><td>Controleer of de klep verstopt is. Verwijder de verstopping en probeer het opnieuw nadat de overbelastingsbeveiliging van de actuator is afgekoeld.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Vastlopen van de klep<\/td><td>Controleer of de klep vastloopt. Verwijder de blokkade en probeer het opnieuw nadat de overbelastingsbeveiliging van de actuator is afgekoeld.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Beschadigd actuatorreductiemechanisme<\/td><td>Verwijder de actuator van de klep en draai aan de hendel. Als deze niet beweegt, vervang dan de actuator.<\/td><\/tr><tr><td><strong>Geen positie-terugkoppelingssignaal<\/strong><\/td><td>1. Onjuiste bedrading bij de schakelaar<\/td><td>Controleer de bedrading aan de hand van het bedradingsschema van de actuator.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Onjuiste instelling van de nok voor volledig openen\/sluiten.<\/td><td>Raadpleeg de handleiding &quot;Elektrische schakelventielen instellen&quot; en stel de nokpositie correct in.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Overstroom veroorzaakt schade aan de positie-terugkoppelingsschakelaar<\/td><td>1. Controleer of de nok voor volledig openen\/sluiten de positie-terugkoppelingsschakelaar correct indrukt, zoals beschreven in de handleiding.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. Controleer of het positieterugkoppelingscircuit gesloten is.<\/td><\/tr><\/tbody><\/table><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d58177d elementor-widget elementor-widget-heading\" data-id=\"d58177d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Controleer of de bedrijfsomstandigheden voldoen aan de parametervereisten.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60cdda7 elementor-widget elementor-widget-text-editor\" data-id=\"60cdda7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"156\" data-end=\"422\">Elektrische actuatoren kunnen defect raken door onjuist gebruik of door gebruik onder ongeschikte bedrijfsomstandigheden. Bij gebruik binnen de in de productspecificaties beschreven bedrijfsomstandigheden kan worden verwacht dat de actuator gedurende een langere periode betrouwbaar functioneert zonder storingen.<\/p><ul data-start=\"424\" data-end=\"1721\"><li class=\"\" data-start=\"424\" data-end=\"610\"><p class=\"\" data-start=\"426\" data-end=\"610\"><strong data-start=\"426\" data-end=\"445\">Voedingsspanning:<\/strong> De voedingsspanning moet binnen het nominale bedrijfsspanningsbereik van de actuator liggen. Over- of onderspanning kan de levensduur van de actuator verkorten.<\/p><\/li><li class=\"\" data-start=\"614\" data-end=\"840\"><p class=\"\" data-start=\"616\" data-end=\"840\"><strong data-start=\"616\" data-end=\"635\">Voedingsstroom:<\/strong> De aanloopstroom van de motor is aanzienlijk hoger dan de nominale stroom. Om een betrouwbare werking te garanderen, dient u een voeding te gebruiken die minstens driemaal de nominale stroom van de actuator kan leveren.<\/p><\/li><li class=\"\" data-start=\"842\" data-end=\"1035\"><p class=\"\" data-start=\"844\" data-end=\"1035\"><strong data-start=\"844\" data-end=\"860\">Temperatuur:<\/strong> Zorg ervoor dat de actuator binnen het nominale temperatuurbereik werkt. Gebruik van de actuator buiten dit bereik kan leiden tot slechte prestaties, een kortere levensduur en uiteindelijk tot uitval.<\/p><\/li><li class=\"\" data-start=\"1037\" data-end=\"1504\"><p class=\"\" data-start=\"1039\" data-end=\"1504\"><strong data-start=\"1039\" data-end=\"1055\">Omgeving:<\/strong> De DCL-schakelaaractuator heeft een IP67-weerbestendigheidsclassificatie, waardoor deze geschikt is voor zowel binnen- als buitentoepassingen. Hij biedt enige bescherming tegen regen en spatwater, wat de levensduur van de actuator verlengt door hem te beschermen tegen regen, sneeuw, ijs en UV-straling (zonlicht). In sterk corrosieve omgevingen kunnen elektronische componenten echter voortijdig defect raken. Niet-explosieveilige actuatoren mogen niet worden gebruikt in explosiegevaarlijke omgevingen.<\/p><\/li><li class=\"\" data-start=\"1506\" data-end=\"1721\"><p class=\"\" data-start=\"1508\" data-end=\"1721\"><strong data-start=\"1508\" data-end=\"1523\">Inschakelduur:<\/strong> De DCL-schakelaaractuator heeft een inschakelduur van 70% (42 seconden bedrijf per minuut, gevolgd door 18 seconden rust). Overschrijding van deze inschakelduur kan ertoe leiden dat de motor in de thermische beveiliging gaat.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0273976 elementor-widget elementor-widget-heading\" data-id=\"0273976\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Controleer de bedrading van de actuator.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9df2216 elementor-widget elementor-widget-text-editor\" data-id=\"9df2216\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"45\" data-end=\"186\">Zorg ervoor dat de actuator correct is aangesloten volgens het bedradingsschema van de fabrikant. Volg deze stappen om de bedrading te controleren:<\/p><ol data-start=\"188\" data-end=\"1007\"><li class=\"\" data-start=\"188\" data-end=\"325\"><p class=\"\" data-start=\"191\" data-end=\"209\"><strong data-start=\"191\" data-end=\"208\">Voeding:<\/strong><\/p><ul data-start=\"213\" data-end=\"325\"><li class=\"\" data-start=\"213\" data-end=\"321\"><p class=\"\" data-start=\"215\" data-end=\"321\">Controleer de voedingsaansluitingen om er zeker van te zijn dat ze overeenkomen met de vereiste ingangsspanning en -stroom van de actuator.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"326\" data-end=\"504\"><p class=\"\" data-start=\"329\" data-end=\"353\"><strong data-start=\"329\" data-end=\"353\">Besturingsverbindingen:<\/strong><\/p><ul data-start=\"357\" data-end=\"504\"><li class=\"\" data-start=\"357\" data-end=\"504\"><p class=\"\" data-start=\"359\" data-end=\"504\">Controleer of de in- en uitgangsaansluitingen goed vastzitten en correct zijn aangesloten volgens het bedradingsschema van de actuator.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"506\" data-end=\"707\"><p class=\"\" data-start=\"509\" data-end=\"527\"><strong data-start=\"509\" data-end=\"527\">Signaalbekabeling:<\/strong><\/p><ul data-start=\"531\" data-end=\"707\"><li class=\"\" data-start=\"531\" data-end=\"639\"><p class=\"\" data-start=\"533\" data-end=\"639\">Controleer de bedrading op stuursignalen, zoals 4-20mA of 0-10V, afhankelijk van de specificaties van de actuator.<\/p><\/li><li class=\"\" data-start=\"643\" data-end=\"707\"><p class=\"\" data-start=\"645\" data-end=\"707\">Controleer of er geen losse verbindingen of kortsluitingen zijn.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"709\" data-end=\"823\"><p class=\"\" data-start=\"712\" data-end=\"726\"><strong data-start=\"712\" data-end=\"726\">Aarding:<\/strong><\/p><ul data-start=\"730\" data-end=\"823\"><li class=\"\" data-start=\"730\" data-end=\"823\"><p class=\"\" data-start=\"732\" data-end=\"823\">Zorg ervoor dat de actuator goed geaard is om elektrische storingen of schade te voorkomen.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"825\" data-end=\"1007\"><p class=\"\" data-start=\"828\" data-end=\"863\"><strong data-start=\"828\" data-end=\"863\">Aansluitingen op andere apparatuur:<\/strong><\/p><ul data-start=\"867\" data-end=\"1007\"><li class=\"\" data-start=\"867\" data-end=\"1007\"><p class=\"\" data-start=\"869\" data-end=\"1007\">Als de actuator is aangesloten op andere apparaten, zorg er dan voor dat die aansluitingen ook correct zijn en geen storingen of stroomproblemen veroorzaken.<\/p><\/li><\/ul><\/li><\/ol><p class=\"\" data-start=\"1009\" data-end=\"1155\">Als de bedrading correct lijkt, maar de actuator nog steeds niet goed functioneert, kan verder onderzoek of de hulp van een technicus nodig zijn.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-84857ae e-flex e-con-boxed e-con e-parent\" data-id=\"84857ae\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cf23cb0 elementor-widget elementor-widget-template\" data-id=\"cf23cb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"template.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-template\">\n\t\t\t\t\t<div data-elementor-type=\"section\" data-elementor-id=\"10969\" class=\"elementor elementor-10969\" data-elementor-post-type=\"elementor_library\">\n\t\t\t<div class=\"elementor-element elementor-element-d642a8e e-flex e-con-boxed e-con e-parent\" data-id=\"d642a8e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-4dcc388 e-con-full e-flex e-con e-child\" data-id=\"4dcc388\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09f4232 elementor-widget elementor-widget-heading\" data-id=\"09f4232\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">A - Met 2 actieve eindpositiesignaaluitgangen<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-daf3293 elementor-widget elementor-widget-image\" data-id=\"daf3293\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"341\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-a.webp\" class=\"attachment-full size-full wp-image-4860\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668A \u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14e5438 elementor-widget elementor-widget-text-editor\" data-id=\"14e5438\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Bedieningsactuator om te openen of te sluiten met K<\/li><li>De uitgangsterminal van de eindpositie OPEN\/CLOSE zal een actief 220VAC-signaal uitzenden zodra de eindpositie is bereikt.<\/li><\/ul><p>\u00a0<\/p><p><strong>Verbindingsdetails:<\/strong><\/p><ol><li>De nulgeleider van de AC85-220V voeding aansluiten op P1.<\/li><li>Schakel de AC85-220V-lijn naar SLUITEN (P2) om de klep te sluiten.<\/li><li>Schakel de AC85-220V-lijn naar OPEN (P3) om de klep te openen.<\/li><li>P5 is de OPEN-eindpositie-aansluiting die een wisselspanning van 220V levert. Deze spanning kan worden gebruikt om een indicatielampje aan te sturen wanneer de actuator de open eindpositie heeft bereikt.<\/li><li>P6 is de OPEN-eindpositie-aansluiting die een wisselspanning van 220V levert. Deze spanning kan worden gebruikt om een indicatielampje aan te sturen wanneer de actuator de gesloten eindpositie heeft bereikt.<\/li><li>Sluit de aarde aan op P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f1a67a7 e-con-full e-flex e-con e-child\" data-id=\"f1a67a7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a942089 elementor-widget elementor-widget-heading\" data-id=\"a942089\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">B - Met 2 passieve eindstandschakelaars<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-766f845 elementor-widget elementor-widget-image\" data-id=\"766f845\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"348\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-b.webp\" class=\"attachment-full size-full wp-image-4858\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668B-\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-799d994 elementor-widget elementor-widget-text-editor\" data-id=\"799d994\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Bedieningsactuator om te openen of te sluiten met K<\/li><li>De uitgangsterminal van de eindpositie OPEN\/CLOSE zal een passief signaal versturen zodra de eindpositie is bereikt.<\/li><\/ul><p>\u00a0<\/p><p><strong>Verbindingsdetails:<\/strong><\/p><ol><li>De nulgeleider van de AC85-220V voeding aansluiten op P1.<\/li><li>Schakel de AC85-220V-lijn naar SLUITEN (P2) om de klep te sluiten.<\/li><li>Schakel de AC85-220V-lijn naar OPEN (P3) om de klep te openen.<\/li><li>P4 is de COM voor het passieve contactsignaal van de eindpositie OPEN\/SLUITEN, dat normaal gesproken is verbonden met signaal GND.<\/li><li>P5 is de OPEN-eindpositie-aansluiting die met COM wordt verbonden wanneer de actuator de open eindpositie bereikt.<\/li><li>P6 is de eindpositie-CLOSE-aansluiting die met COM wordt verbonden wanneer de actuator de eindpositie (sluiten) heeft bereikt.<\/li><li>Sluit de aarde aan op P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-738bf4f e-con-full e-flex e-con e-child\" data-id=\"738bf4f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5a73aaa elementor-widget elementor-widget-heading\" data-id=\"5a73aaa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">G - DC-motor met 2 eindstandschakelaars<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c393f4 elementor-widget elementor-widget-image\" data-id=\"8c393f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"391\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-g.webp\" class=\"attachment-full size-full wp-image-4853\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668G \u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a35d4cf elementor-widget elementor-widget-text-editor\" data-id=\"a35d4cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>De actuator wordt aangestuurd om te openen of te sluiten door de richting van de voedingsspanning tussen klem 1 en 2.<\/li><li>De uitgangsterminal van de eindpositie OPEN\/CLOSE zal een passief signaal versturen zodra de eindpositie is bereikt.<\/li><\/ul><p>\u00a0<\/p><p><strong>Verbindingsdetails:<\/strong><\/p><ol><li>Sluit DC24V+ aan op P1 en DC24V- op P2 om de klep te sluiten.<\/li><li>Sluit DC24V+ aan op P2 en DC24V- op P1 om de klep te sluiten.<\/li><li>P3 is de COM voor het passieve contactsignaal van de eindpositie OPEN\/SLUITEN, dat normaal gesproken is verbonden met signaal GND.<\/li><li>P4 is de OPEN-eindpositie-aansluiting die met COM verbonden wordt wanneer de actuator de open eindpositie bereikt.<\/li><li>P5 is de CLOSE-eindpositie-aansluiting die met COM wordt verbonden wanneer de actuator de sluit-eindpositie bereikt.<\/li><li>Sluit de aarde aan op P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ff65758 e-con-full e-flex e-con e-parent\" data-id=\"ff65758\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-d5dc048 e-con-full e-flex e-con e-child\" data-id=\"d5dc048\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-527200f elementor-widget elementor-widget-text-editor\" data-id=\"527200f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Opmerking:<\/p><ul><li>Het circuit binnen het gestippelde kader is het interne circuit van de actuator. Het circuit daarbuiten is een demonstratie van de elektrische aansluiting voor het gebruik van de actuator.<\/li><li>Mocht u andere specifieke wensen hebben met betrekking tot de aansluiting van het circuit, neem dan gerust contact op met onze technische ondersteuning.\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-002d845 elementor-widget elementor-widget-text-editor\" data-id=\"002d845\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wanneer u ter plaatse problemen ondervindt, kunt u direct contact opnemen met onze technische dienst voor hulp bij het diagnosticeren en oplossen van het probleem. <br \/>Contacttelefoonnummer: 13026331611 (dhr. Chen)<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Deze handleiding is van toepassing op de DCL Ultra-Small Series actuatoren, met de volgende modellen: DCL-02A, DCL-02B en DCL-02G. Veelvoorkomende storingen en probleemoplossingsmethoden Storing Mogelijke oorzaken Probleemoplossingsmethoden Actuator opent of sluit niet bij de eerste inschakeling 1. Onjuiste bedrading Controleer de bedrading volgens het bedradingsschema van de actuator. 2. Onjuiste voeding Zorg ervoor dat [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[103],"tags":[53],"class_list":["post-6033","post","type-post","status-publish","format-standard","hentry","category-mr-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/nl_nl\/wp-json\/wp\/v2\/posts\/6033","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/nl_nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/nl_nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/nl_nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/nl_nl\/wp-json\/wp\/v2\/comments?post=6033"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/nl_nl\/wp-json\/wp\/v2\/posts\/6033\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/nl_nl\/wp-json\/wp\/v2\/media?parent=6033"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/nl_nl\/wp-json\/wp\/v2\/categories?post=6033"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/nl_nl\/wp-json\/wp\/v2\/tags?post=6033"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}