Biežāk sastopamās modulējošo aktuatoru kļūmes un problēmu novēršana
This guide applies to the modulating actuators of the DCL explosion-proof series, weather-proof series, and quick-turn series. The models are as follows: Weather-proof actuator: DCL-05, DCL-10, DCL-20, DCL-40, DCL-60, DCL-100, DCL-160, DCL-250Explosion-proof actuator: DCL-Ex05, DCL-Ex10, DCL-Ex20, DCL-Ex40, DCL-Ex60Quick-turn actuator: DCL-K05, DCL-K10, DCL-K20, DCL-K40, DCL-K100 Common Faults and Fault Exclusion Methods Fault Possible Causes Fault […]
Biežāk sastopamās ON-OFF izpildmehānismu kļūmes un problēmu novēršana

This guide applies to the switch-type actuators of the DCL explosion-proof series, standard series, and quick-open series. The models are as follows: Weather-proof Actuator: DCL-05, DCL-10, DCL-20, DCL-40, DCL-60, DCL-100, DCL-160, DCL-250Explosion-Proof Actuator: DCL-Ex05, DCL-Ex10, DCL-Ex20, DCL-Ex40, DCL-Ex60Quick-Turn Actuator: DCL-K05, DCL-K10, DCL-K20, DCL-K40, DCL-K100 Common Faults and Troubleshooting Methods Fault Possible Causes Troubleshooting Methods […]
DCL izpildmehānisma Modbus lietojumprogrammas piezīme

DCL izpildmehānismi atbalsta Modbus-RTU protokolu. Atsaucoties uz šo lietojumprogrammas rokasgrāmatu, jūs varat pievienot DCL izpildmehānismus Modbus. Panelis SF-LC/MB SF-ZC/MB 1. Saskarnes definīcija P1: 220 V AC NP2: 220 V AC LP3: 4–20 mA ieeja – P4: 4–20 mA ieeja+ P5: 4–20 mA izeja- P6: 4–20 mA izeja+ P7: RS485 AP8: RS485 B 2. Poga “Atvērt”: Izmanto iestatīšanas režīmā. Nospiediet šo pogu, lai atvērtu izpildmehānismu, un atlaidiet to, lai apturētu. Nospiediet “Iestatīt” […]
DCL-250 Actuator Runs Fault-Free for 10 Years

Customer Reached Out to Us Again A customer contacted us to place a new order for electric actuators. However, the nameplates on the previously installed actuators had been corroded, making it impossible to identify the product model. The customer sent site photos for model confirmation. 13 Years of Reliable Operation with DCL-250 Actuators After analyzing […]
Piedziņu veidi un kā izvēlēties pareizo
Actuators can be classified based on their driving method into the following categories: 1. Electric Actuators Electric actuators use an electric motor as the power source, converting electrical energy into mechanical motion to drive the valve. Advantages: ✔ Adjustable speed✔ High positioning accuracy✔ Large torque output Disadvantages: ✖ Thermal effects of the motor may trigger […]
Kā mitrums samazina izpildmehānismu (elektrisko vārstu) kalpošanas laiku?
Humidity is well known to cause damage to electronic components. One of the primary ways humidity reduces the lifespan of electric actuators is through ionic migration short circuits. 1. What is Ionic Migration Short Circuit? Ionic migration occurs when moisture and contaminants on a circuit board facilitate the movement of ions between conductors, leading to […]
Ko nozīmē S2 darba cikls izpildmehānismos (elektriskajos vārstos)?
Many people have questions about the S2 duty cycle in actuators or electric valves. What does it mean, and why is it defined this way? 1. The Origin of S1, S2, S3, and S6 Duty Cycles The S1, S2, S3, and S6 duty cycles originate from electric motor classifications, with a primary focus on thermal […]
Vai DCL izpildmehānismus var izmantot augstkalnu apgabalos?
Augstkalnu vide rada unikālus izaicinājumus, kas var ietekmēt DCL elektrisko izpildmehānismu veiktspēju. Šajā ziņojumā ir izvērtēta to lietošana 3000 metru augstumā virs jūras līmeņa. 1. Kā liels augstums ietekmē elektroierīces Pieaugot augstumam:✔ Gaisa blīvums un spiediens samazinās, kā rezultātā samazinās izolācijas izturība un palielinās elektriskās ķēdes pārrāvuma risks.✔ Dzesēšanas efektivitāte samazinās, izraisot […]
Kāpēc sprieguma izejas signāli svārstās noteiktos apstākļos?
1. Sprieguma signāla pārraides ceļš Kā parādīts 1. attēlā, sprieguma signāla pārraides sistēma sastāv no trim galvenajām sastāvdaļām: Negatīvās atgriezeniskās saites sprieguma izejas ķēde Signāla pārraides kabelis Ietver parazitāro kapacitāti (C1) un parazitāro induktivitāti (L1), kas ir atkarīgas no kabeļa garuma un vadu izkārtojuma. Ieejas signāla uztveršanas ķēde Var ietvert zemfrekvences filtru (L2, […]
Kā konfigurēt ieslēgšanas/izslēgšanas izpildmehānismus ar pozīcijas devēju?

1. Mehāniskā uzstādīšana 1. Mehāniskā uzstādīšana Lai pareizi uzstādītu izpildmehānismu uz vārsta, skatiet sadaļu “Kā uzstādīt izpildmehānismu uz vārsta” un manuāli darbiniet to, lai pārliecinātos par pareizu darbību. Lai pareizi pielāgotu izpildmehānisma elektriskās robežas (aizvēršanas robeža CLS […]), ievērojiet vadlīnijas sadaļā “Kā iestatīt IESLĒGŠANAS-IZSLĒGŠANAS elektrisko vārstu”.