{"id":10958,"date":"2025-03-27T07:48:51","date_gmt":"2025-03-27T07:48:51","guid":{"rendered":"https:\/\/dclcontrols.com\/?p=10958"},"modified":"2025-04-18T03:32:58","modified_gmt":"2025-04-18T03:32:58","slug":"mr-actuator","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/it_it\/supporto\/attuatore-mr","title":{"rendered":"Manutenzione e riparazione dell'attuatore DCL"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"10958\" class=\"elementor elementor-10958\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-355d877 e-con-full e-flex e-con e-parent\" data-id=\"355d877\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-99be193 e-con-full e-flex e-con e-child\" data-id=\"99be193\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9697a47 elementor-widget elementor-widget-heading\" data-id=\"9697a47\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\"><a href=\"\/it_it\/supporto\/ug\/5-passaggi-per-utilizzare-lattuatore\/\">Guasti comuni e risoluzione dei problemi<\/a><\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef0dbfc elementor-widget elementor-widget-text-editor\" data-id=\"ef0dbfc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><span style=\"text-decoration: underline;\"><a href=\"\/it_it\/supporto\/attuatore-mr\/attuatore-on-off\/\">per attuatore ON-OFF<\/a><\/span><\/li><li><span style=\"text-decoration: underline;\"><a href=\"\/it_it\/attuatore-mr\/attuatore-modulante\/\">per attuatore modulante<\/a><\/span><\/li><li><span style=\"text-decoration: underline;\"><a href=\"\/it_it\/supporto\/attuatore-mr\/dcl-gey-24v-modulante\/\">per attuatore DC24V<\/a><\/span><\/li><li><span style=\"text-decoration: underline;\"><a href=\"\/it_it\/supporto\/attuatore-mr\/attuatore-on-off-dcl-02\/\">per attuatore ON-OFF DCL-02<\/a><\/span><\/li><li><span style=\"text-decoration: underline;\"><a href=\"\/it_it\/supporto\/attuatore-mr\/attuatore-modulante-dcl-02\/\">per attuatore modulante DCL-02<\/a><\/span><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4c98fd1 e-con-full e-flex e-con e-parent\" data-id=\"4c98fd1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1a150dc elementor-widget elementor-widget-heading\" data-id=\"1a150dc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Di pi\u00f9<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-52593e0 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"52593e0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7b1ed39 e-con-full e-flex e-con e-child\" data-id=\"7b1ed39\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-22f0097 e-con-full e-flex e-con e-child\" data-id=\"22f0097\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ee59536 elementor-grid-1 elementor-grid-tablet-2 elementor-grid-mobile-1 elementor-posts--thumbnail-top elementor-card-shadow-yes elementor-posts__hover-gradient elementor-widget elementor-widget-posts\" data-id=\"ee59536\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;cards_columns&quot;:&quot;1&quot;,&quot;cards_columns_tablet&quot;:&quot;2&quot;,&quot;cards_columns_mobile&quot;:&quot;1&quot;,&quot;cards_row_gap&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:35,&quot;sizes&quot;:[]},&quot;cards_row_gap_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;cards_row_gap_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"posts.cards\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-posts-container elementor-posts elementor-posts--skin-cards elementor-grid\">\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-6041 post type-post status-publish format-standard hentry category-mr-actuator tag-actuator tag-dcl-gey tag-explosion-proof-actuator tag-general-actuator tag-fast-move-actuator tag-trouble-shooting-guide\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/dclactuator.com\/it_it\/supporto\/attuatore-mr\/dcl-gey-24v-modulante\" >\n\t\t\t\tGuasti comuni e risoluzione dei problemi per attuatori modulanti a 24 V CC\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p>Questa guida \u00e8 applicabile agli attuatori modulanti DCL serie antideflagranti \/ serie resistenti agli agenti atmosferici \/ serie a rotazione rapida alimentati a 24 V CC, con i seguenti modelli: Attuatore resistente agli agenti atmosferici: DCL-02GEY, DCL-05GEY, DCL-10GEY, DCL-20GEY, DCL-40GEY, DCL-60GEY Attuatore antideflagrante: DCL-Ex05GEY, DCL-Ex10GEY, DCL-Ex20GEY, DCL-Ex40GEY, DCL-Ex60GEY Fammi sapere se hai bisogno di ulteriore assistenza con questa guida! Aprire il coperchio della camera elettrica Utilizzare un cacciavite a croce per svitare le 4 viti di fissaggio sul coperchio esterno della camera di controllo. Verificare lo stato della spia di segnalazione guasti<\/p>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__meta-data\">\n\t\t\t\t\t<span class=\"elementor-post-date\">\n\t\t\t3 agosto 2023\t\t<\/span>\n\t\t\t\t<span class=\"elementor-post-time\">\n\t\t\t20:58\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<\/div>\n\t\t\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1c1fdba e-con-full e-flex e-con e-child\" data-id=\"1c1fdba\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a186b2a elementor-grid-1 elementor-posts--thumbnail-none elementor-grid-tablet-2 elementor-grid-mobile-1 elementor-widget elementor-widget-posts\" data-id=\"a186b2a\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;classic_columns&quot;:&quot;1&quot;,&quot;classic_columns_tablet&quot;:&quot;2&quot;,&quot;classic_columns_mobile&quot;:&quot;1&quot;,&quot;classic_row_gap&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:35,&quot;sizes&quot;:[]},&quot;classic_row_gap_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;classic_row_gap_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"posts.classic\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-posts-container elementor-posts elementor-posts--skin-classic elementor-grid\">\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-6033 post type-post status-publish format-standard hentry category-mr-actuator tag-actuator\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/dclactuator.com\/it_it\/supporto\/attuatore-mr\/attuatore-on-off-dcl-02\" >\n\t\t\t\tGuasti comuni e risoluzione dei problemi per gli attuatori ON-OFF DCL-02\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<div class=\"elementor-post__meta-data\">\n\t\t\t\t\t<span class=\"elementor-post-date\">\n\t\t\t3 agosto 2023\t\t<\/span>\n\t\t\t\t<span class=\"elementor-post-time\">\n\t\t\t20:44\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p>Questa guida \u00e8 applicabile agli attuatori della serie DCL Ultra-Small, con i seguenti modelli: DCL-02A DCL-02B DCL-02G Guasti comuni e metodi di risoluzione Guasto Possibili cause Metodi di risoluzione L&#039;attuatore non si apre o non si chiude all&#039;avvio iniziale 1. Cablaggio errato Controllare il cablaggio secondo lo schema elettrico dell&#039;attuatore. 2. Alimentazione errata Assicurarsi che la tensione di alimentazione sia<\/p>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-6034 post type-post status-publish format-standard hentry category-mr-actuator tag-actuator\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/dclactuator.com\/it_it\/supporto\/attuatore-mr\/attuatore-modulante-dcl-02\" >\n\t\t\t\tGuasti comuni e risoluzione dei problemi per gli attuatori modulanti DCL-02\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<div class=\"elementor-post__meta-data\">\n\t\t\t\t\t<span class=\"elementor-post-date\">\n\t\t\t3 agosto 2023\t\t<\/span>\n\t\t\t\t<span class=\"elementor-post-time\">\n\t\t\t20:40\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p>Questa guida si applica agli attuatori modulanti ultra piccoli DCL, modello come segue: DCL-02E Guasti comuni e metodi di risoluzione Guasto Possibile causa Metodo di risoluzione L&#039;attuatore non si apre o non si chiude all&#039;avvio 1. Cablaggio errato Controllare il cablaggio secondo lo schema elettrico dell&#039;attuatore per confermare che sia corretto. 2. Alimentazione errata Assicurarsi che l&#039;uscita dell&#039;alimentatore<\/p>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-6035 post type-post status-publish format-standard hentry category-mr-actuator tag-actuator\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/dclactuator.com\/it_it\/supporto\/attuatore-mr\/attuatore-modulante\" >\n\t\t\t\tGuasti comuni e risoluzione dei problemi per gli attuatori modulanti\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<div class=\"elementor-post__meta-data\">\n\t\t\t\t\t<span class=\"elementor-post-date\">\n\t\t\t3 agosto 2023\t\t<\/span>\n\t\t\t\t<span class=\"elementor-post-time\">\n\t\t\t20:35\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p>Questa guida si applica agli attuatori modulanti delle serie antideflagranti, resistenti agli agenti atmosferici e a rotazione rapida DCL. I modelli sono i seguenti: Attuatore resistente agli agenti atmosferici: DCL-05, DCL-10, DCL-20, DCL-40, DCL-60, DCL-100, DCL-160, DCL-250 Attuatore antideflagrante: DCL-Ex05, DCL-Ex10, DCL-Ex20, DCL-Ex40, DCL-Ex60 Attuatore a rotazione rapida: DCL-K05, DCL-K10, DCL-K20, DCL-K40, DCL-K100 Guasti comuni e metodi di esclusione dei guasti Possibili cause del guasto Metodi di esclusione dei guasti L&#039;attuatore non<\/p>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<\/div>\n\t\t\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69533da elementor-widget elementor-widget-heading\" data-id=\"69533da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-heading-title elementor-size-default\"><a href=\"\/it_it\/supporto\/attuatore-mr\/\">Per saperne di pi\u00f9 &gt;<\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Guasti comuni e risoluzione dei problemi per l&#039;attuatore ON-OFF per l&#039;attuatore di modulazione per l&#039;attuatore DC24V per l&#039;attuatore ON-OFF DCL-02 per l&#039;attuatore di modulazione DCL-02 Visualizza altro &gt;<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[94],"tags":[],"class_list":["post-10958","post","type-post","status-publish","format-standard","hentry","category-support"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/it_it\/wp-json\/wp\/v2\/posts\/10958","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/it_it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/it_it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/it_it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/it_it\/wp-json\/wp\/v2\/comments?post=10958"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/it_it\/wp-json\/wp\/v2\/posts\/10958\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/it_it\/wp-json\/wp\/v2\/media?parent=10958"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/it_it\/wp-json\/wp\/v2\/categories?post=10958"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/it_it\/wp-json\/wp\/v2\/tags?post=10958"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}