{"id":10862,"date":"2025-03-21T03:41:07","date_gmt":"2025-03-21T03:41:07","guid":{"rendered":"https:\/\/dclcontrols.com\/?p=10862"},"modified":"2025-03-27T07:12:47","modified_gmt":"2025-03-27T07:12:47","slug":"how-actuator-works","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/it\/supporto\/attuatore-2\/come-funziona-un-attuatore","title":{"rendered":"Come funziona un attuatore elettrico?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"10862\" class=\"elementor elementor-10862\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0b75a7f e-con-full e-flex e-con e-parent\" data-id=\"0b75a7f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-ca7c2bb e-con-full e-flex e-con e-child\" data-id=\"ca7c2bb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7a5be97 elementor-widget elementor-widget-image\" data-id=\"7a5be97\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"696\" height=\"600\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-product-line.webp\" class=\"attachment-full size-full wp-image-4829\" alt=\"DCL \u534e\u6613\u667a\u63a7 \u6267\u884c\u5668 \u4ea7\u54c1\u7ebf | Attuatori DCL\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f2b735 elementor-widget elementor-widget-text-editor\" data-id=\"1f2b735\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Una volta collegati a un&#039;alimentazione elettrica (AC 380V, AC 220V, AC 24V o DC 24V), gli attuatori elettrici DCL possono essere controllati da un sistema di controllo distribuito (DCS) utilizzando diversi segnali di controllo, tra cui segnali analogici, segnali digitali, comunicazione bus e reti IoT. L&#039;attuatore aziona la valvola elettrica per aprirla completamente, chiuderla completamente o regolarla in una posizione specifica, consentendo il controllo ad anello aperto o ad anello chiuso dei principali parametri di processo del fluido, come temperatura, portata e pressione.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f0558f2 elementor-widget elementor-widget-text-editor\" data-id=\"f0558f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Come funziona un attuatore elettrico ON-OFF?<\/strong><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#on-off-actuator\">Stato dell&#039;attuatore<\/a><\/span><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#with-relay-ac220v\">Alimentazione tramite corrente alternata 85-265 V e controllo tramite rel\u00e8.<\/a><\/span><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#with-relay-dc24v\">Alimentazione a 24 V CC e controllo tramite rel\u00e8.<\/a><\/span><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#with-switch-ac220v\">Alimentazione a 220 V CA e controllo tramite interruttore<\/a><\/span><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#with-switch-dc24v\">Alimentazione a 24 V CC e controllo tramite interruttore.<\/a><\/span><\/p><p><strong>Come funziona un attuatore elettrico modulante?<\/strong><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#on-off-actuator\">Stato dell&#039;attuatore<\/a><\/span><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#with-4-20ma\">Controllo tramite 4-20mA<\/a><\/span><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#with-2-10v\">Controllo tramite 2-10V<\/a><\/span><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#with-bus\">Controllo tramite bus di campo<\/a><\/span><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#with-iiot\">Controllo tramite IIoT<\/a><\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-103c89f elementor-widget elementor-widget-heading\" data-id=\"103c89f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"on-off-actuator\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Attuatore elettrico ON-OFF<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-58887b7 elementor-widget elementor-widget-text-editor\" data-id=\"58887b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Una volta installato un attuatore elettrico on\/off (valvola) su una tubazione, questo pu\u00f2 essere controllato tramite un rel\u00e8, un interruttore o un PLC (DCS) per aprire o chiudere la valvola, consentendo il controllo del flusso del fluido.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-31dce6f elementor-widget elementor-widget-heading\" data-id=\"31dce6f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Stato dell&#039;attuatore elettrico ON-OFF<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e0e8c11 elementor-widget elementor-widget-text-editor\" data-id=\"e0e8c11\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li data-start=\"265\" data-end=\"336\"><strong data-start=\"267\" data-end=\"275\">Aprire<\/strong> \u2013 La valvola \u00e8 completamente aperta, consentendo il passaggio del fluido.<\/li><li data-start=\"337\" data-end=\"401\"><strong data-start=\"339\" data-end=\"349\">Chiuso<\/strong> \u2013 La valvola \u00e8 completamente chiusa, interrompendo il flusso del fluido.<\/li><li data-start=\"402\" data-end=\"480\"><strong data-start=\"404\" data-end=\"421\">In transizione<\/strong> \u2013 La valvola si muove tra la posizione aperta e quella chiusa.<\/li><li data-start=\"481\" data-end=\"590\"><strong data-start=\"483\" data-end=\"498\">Guasto\/Errore<\/strong> \u2013 L&#039;attuatore ha riscontrato un problema, come un&#039;interruzione di corrente, un sovraccarico o un&#039;ostruzione.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-14b65f8 e-con-full e-flex e-con e-child\" data-id=\"14b65f8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-6ee4fb3 e-con-full e-flex e-con e-child\" data-id=\"6ee4fb3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3808ea8 elementor-widget elementor-widget-image\" data-id=\"3808ea8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"422\" height=\"388\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/08\/vale-closed.webp\" class=\"attachment-full size-full wp-image-6112\" alt=\"\u7535\u52a8\u9600\u95e8\u5173\u95ed\u793a\u610f\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e60b796 e-con-full e-flex e-con e-child\" data-id=\"e60b796\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d656541 elementor-widget elementor-widget-image\" data-id=\"d656541\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"466\" height=\"388\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/08\/vale-open.webp\" class=\"attachment-full size-full wp-image-6114\" alt=\"\u7535\u52a8\u9600\u95e8\u5168\u5f00\u793a\u610f\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3be24e1 elementor-widget elementor-widget-heading\" data-id=\"3be24e1\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"with-relay-ac220v\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Alimentazione tramite corrente alternata 85-265 V e controllo tramite rel\u00e8.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de79426 elementor-widget elementor-widget-image\" data-id=\"de79426\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"826\" height=\"307\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/08\/ac220v-switch-actuator-first-step-with-relay.webp\" class=\"attachment-full size-full wp-image-6108\" alt=\"Generatore di corrente DCL (AC220V)\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3afd61b elementor-widget elementor-widget-text-editor\" data-id=\"3afd61b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong data-start=\"44\" data-end=\"115\">Quando la linea L viene commutata sul terminale di ingresso &quot;off&quot; tramite un rel\u00e8<\/strong>L&#039;attuatore spinge la valvola fino alla posizione di chiusura. Una volta che la valvola raggiunge la posizione completamente chiusa, l&#039;attuatore si arresta e la valvola elettrica rimane chiusa.<\/li><li><strong data-start=\"292\" data-end=\"362\">Quando la linea L viene commutata sul terminale di ingresso &quot;on&quot; tramite un rel\u00e8<\/strong>L&#039;attuatore spinge la valvola in posizione aperta. Una volta che la valvola raggiunge la posizione completamente aperta, l&#039;attuatore si arresta e la valvola elettrica rimane completamente aperta.<\/li><li><strong data-start=\"539\" data-end=\"574\">Durante il funzionamento dell&#039;attuatore<\/strong>Se l&#039;alimentazione sulla linea CA 220V L viene interrotta, l&#039;attuatore si arresta e la valvola elettrica mantiene la sua posizione attuale.<\/li><li><strong data-start=\"716\" data-end=\"775\">Se l&#039;attuatore \u00e8 dotato di un deumidificatore riscaldante<\/strong>\u00c8 importante mantenere alimentata la linea CA 220V L dopo aver azionato l&#039;attuatore fino alla posizione completamente aperta o chiusa.<\/li><li style=\"list-style-type: none;\">\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4df2295 elementor-widget elementor-widget-heading\" data-id=\"4df2295\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"with-relay-dc24v\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Alimentazione a 24 V CC e controllo tramite rel\u00e8.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bb7e0f9 elementor-widget elementor-widget-image\" data-id=\"bb7e0f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"883\" height=\"330\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/08\/dc24v-switch-actuator-first-step-with-relay.webp\" class=\"attachment-full size-full wp-image-6124\" alt=\"DCL DC24V alimentatore di rete\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9203b0c elementor-widget elementor-widget-text-editor\" data-id=\"9203b0c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong data-start=\"72\" data-end=\"196\">Quando il rel\u00e8 commuta la linea di alimentazione + al terminale di ingresso \u201caperto\u201d e la linea di alimentazione \u2013 al terminale di ingresso \u201cchiuso\u201d.<\/strong>L&#039;attuatore spinge la valvola in posizione aperta. Una volta che la valvola raggiunge la posizione completamente aperta, l&#039;attuatore si arresta e la valvola elettrica rimane completamente aperta.<\/li><li><strong data-start=\"373\" data-end=\"497\">Quando il rel\u00e8 commuta la linea di alimentazione + al terminale di ingresso \u201cchiuso\u201d e la linea di alimentazione \u2013 al terminale di ingresso \u201caperto\u201d.<\/strong>L&#039;attuatore spinge la valvola fino alla posizione di chiusura. Una volta che la valvola raggiunge la posizione completamente chiusa, l&#039;attuatore si arresta e la valvola elettrica rimane completamente chiusa.<\/li><li><strong data-start=\"680\" data-end=\"715\">Durante il funzionamento dell&#039;attuatore<\/strong>Se l&#039;alimentazione elettrica viene interrotta, l&#039;attuatore si arresta e la valvola elettrica mantiene la sua posizione attuale.<\/li><li><strong data-start=\"836\" data-end=\"895\">Se l&#039;attuatore \u00e8 dotato di un deumidificatore riscaldante<\/strong>, assicurarsi che l&#039;alimentazione elettrica rimanga attiva dopo aver azionato l&#039;attuatore fino alla posizione completamente aperta o chiusa.<\/li><li style=\"list-style-type: none;\">\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-70cefeb elementor-widget elementor-widget-heading\" data-id=\"70cefeb\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"with-switch-ac220v\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Alimentazione tramite corrente alternata 85-265 V e controllo tramite interruttore.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9aaf18f elementor-widget elementor-widget-image\" data-id=\"9aaf18f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"826\" height=\"307\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/08\/ac220v-switch-actuator-first-step-with-switch.webp\" class=\"attachment-full size-full wp-image-6110\" alt=\"Generatore di corrente DCL (AC220V)\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d4d3474 elementor-widget elementor-widget-text-editor\" data-id=\"d4d3474\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong>Quando la linea L viene commutata sul terminale di ingresso &quot;chiuso&quot; tramite un interruttore meccanico<\/strong>L&#039;attuatore spinge la valvola fino alla posizione di chiusura. Una volta che la valvola raggiunge la posizione completamente chiusa, l&#039;attuatore si arresta e la valvola elettrica rimane completamente chiusa.<\/li><li><strong>Quando la linea L viene commutata sul terminale di ingresso &quot;aperto&quot; tramite un interruttore meccanico<\/strong>L&#039;attuatore spinge la valvola in posizione aperta. Una volta che la valvola raggiunge la posizione completamente aperta, l&#039;attuatore si arresta e la valvola elettrica rimane completamente aperta.<\/li><li><strong>Durante il funzionamento dell&#039;attuatore<\/strong>Se l&#039;alimentazione sulla linea CA 220V L viene interrotta, l&#039;attuatore si arresta e la valvola elettrica mantiene la sua posizione attuale.<\/li><li><strong>Se l&#039;attuatore \u00e8 dotato di un deumidificatore riscaldante<\/strong>, assicurarsi che la linea CA 220 V L rimanga alimentata dopo aver azionato l&#039;attuatore fino alla posizione completamente aperta o chiusa.<\/li><\/ul><p><strong>Nota<\/strong>Lo schema elettrico sopra riportato mostra la funzionalit\u00e0 di base dell&#039;attuatore on\/off (elettrovalvola). Nelle applicazioni pratiche, \u00e8 opportuno considerare anche dispositivi di protezione aggiuntivi come fusibili e limitatori di corrente.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ad699a elementor-widget elementor-widget-heading\" data-id=\"7ad699a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"with-switch-dc24v\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Alimentazione a 24 V CC e controllo tramite interruttore.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-278b991 elementor-widget elementor-widget-image\" data-id=\"278b991\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"844\" height=\"330\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/08\/dc24v-switch-actuator-first-step-with-switch.webp\" class=\"attachment-full size-full wp-image-6126\" alt=\"DCL 24V alimentatore di rete\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c0f56e elementor-widget elementor-widget-text-editor\" data-id=\"2c0f56e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong>Quando l&#039;interruttore meccanico collega la linea di alimentazione + al terminale di ingresso \u201caperto\u201d e la linea di alimentazione \u2013 al terminale di ingresso \u201cchiuso\u201d.<\/strong>L&#039;attuatore spinge la valvola in posizione aperta. Una volta che la valvola raggiunge la posizione completamente aperta, l&#039;attuatore si arresta e la valvola elettrica rimane completamente aperta.<\/li><li><strong>Quando l&#039;interruttore meccanico collega la linea di alimentazione + al terminale di ingresso \u201cchiuso\u201d e la linea di alimentazione \u2013 al terminale di ingresso \u201caperto\u201d.<\/strong>L&#039;attuatore spinge la valvola fino alla posizione di chiusura. Una volta che la valvola raggiunge la posizione completamente chiusa, l&#039;attuatore si arresta e la valvola elettrica rimane completamente chiusa.<\/li><li><strong>Durante il funzionamento dell&#039;attuatore<\/strong>Se l&#039;alimentazione elettrica viene interrotta, l&#039;attuatore si arresta e la valvola elettrica mantiene la sua posizione attuale.<\/li><li><strong>Se l&#039;attuatore \u00e8 dotato di un deumidificatore riscaldante<\/strong>, assicurarsi che l&#039;alimentazione elettrica rimanga attiva dopo aver azionato l&#039;attuatore fino alla posizione completamente aperta o chiusa.<\/li><\/ul><p><strong>Nota<\/strong>Lo schema elettrico sopra riportato mostra la funzionalit\u00e0 di base dell&#039;attuatore on\/off (elettrovalvola). Nelle applicazioni pratiche, \u00e8 opportuno considerare anche dispositivi di protezione aggiuntivi come fusibili e limitatori di corrente.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6d28c6c elementor-widget elementor-widget-heading\" data-id=\"6d28c6c\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"modulation-actuator\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Attuatore elettrico modulante<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9016b5a elementor-widget elementor-widget-text-editor\" data-id=\"9016b5a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Installando un attuatore elettrico modulante DCL (valvola) sulla tubazione, \u00e8 possibile controllarne la posizione tramite segnali analogici da 4-20 mA o 0-10 V, sistemi bus (come Modbus, CAN, Profibus, DeviceNet, Foundation Fieldbus, HART, Ethernet) o reti IoT, consentendo una regolazione precisa del flusso del fluido.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-326b679 elementor-widget elementor-widget-heading\" data-id=\"326b679\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Stato dell&#039;attuatore elettrico modulante<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2961431 elementor-widget elementor-widget-text-editor\" data-id=\"2961431\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li data-start=\"386\" data-end=\"487\"><strong data-start=\"388\" data-end=\"396\">Aprire<\/strong> \u2013 La valvola \u00e8 parzialmente o completamente aperta in base al segnale di controllo, consentendo il flusso del fluido.<\/li><li data-start=\"488\" data-end=\"608\"><strong data-start=\"490\" data-end=\"500\">Chiuso<\/strong> \u2013 La valvola \u00e8 parzialmente o completamente chiusa in base al segnale di controllo, limitando o interrompendo il flusso del fluido.<\/li><li data-start=\"609\" data-end=\"722\"><strong data-start=\"611\" data-end=\"628\">In transizione<\/strong> \u2013 La valvola si regola tra la posizione aperta e quella chiusa in base al segnale di controllo.<\/li><li data-start=\"723\" data-end=\"883\"><strong data-start=\"725\" data-end=\"740\">Errore\/allarme<\/strong> \u2013 L&#039;attuatore rileva un problema, come un malfunzionamento o un errore di comunicazione, e la valvola potrebbe arrestarsi o non raggiungere la posizione desiderata.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7b6a6ac e-con-full e-flex e-con e-child\" data-id=\"7b6a6ac\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-c3733d2 e-con-full e-flex e-con e-child\" data-id=\"c3733d2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5c1f25c elementor-widget elementor-widget-image\" data-id=\"5c1f25c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"422\" height=\"388\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/08\/vale-closed.webp\" class=\"attachment-full size-full wp-image-6112\" alt=\"\u7535\u52a8\u9600\u95e8\u5173\u95ed\u793a\u610f\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e096f2f e-con-full e-flex e-con e-child\" data-id=\"e096f2f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-84db4e7 elementor-widget elementor-widget-image\" data-id=\"84db4e7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"487\" height=\"378\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/08\/vale-opening.webp\" class=\"attachment-full size-full wp-image-6119\" alt=\"DCL fornitore di servizi\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-94f167e e-con-full e-flex e-con e-child\" data-id=\"94f167e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a9edcb7 elementor-widget elementor-widget-image\" data-id=\"a9edcb7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"466\" height=\"388\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/08\/vale-open.webp\" class=\"attachment-full size-full wp-image-6114\" alt=\"\u7535\u52a8\u9600\u95e8\u5168\u5f00\u793a\u610f\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9610455 elementor-widget elementor-widget-heading\" data-id=\"9610455\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"with-4-20ma\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Controllo tramite 4-20mA<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-97f2bb5 elementor-widget elementor-widget-image\" data-id=\"97f2bb5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"689\" height=\"296\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/08\/servo-actuator-first-step.webp\" class=\"attachment-full size-full wp-image-6117\" alt=\"DCL fornitore di servizi di assistenza clienti\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6a2a00d elementor-widget elementor-widget-text-editor\" data-id=\"6a2a00d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>L&#039;attuatore regola la posizione della valvola secondo una relazione lineare con il segnale di ingresso 4-20mA:<ul><li><strong>4 mA<\/strong> corrisponde alla valvola completamente chiusa.<\/li><li><strong>20 mA<\/strong> corrisponde alla valvola completamente aperta.<\/li><\/ul><\/li><li>Se il segnale di ingresso cade fuori dall&#039;intervallo specificato, l&#039;attuatore entra nell&#039; <strong>perdita di segnale<\/strong> modalit\u00e0. A seconda delle impostazioni dell&#039;utente, l&#039;attuatore azioner\u00e0 la valvola per:<ul><li><strong>Completamente aperto<\/strong>,<\/li><li><strong>Completamente chiuso<\/strong>, O<\/li><li><strong>Mantenere la posizione della valvola<\/strong> nel punto in cui il segnale \u00e8 andato perso.<\/li><\/ul><\/li><\/ul><p><strong>Nota<\/strong>Lo schema elettrico sopra riportato mostra la funzionalit\u00e0 di base di un attuatore modulante (valvola elettrica). Nelle applicazioni pratiche, \u00e8 opportuno considerare anche dispositivi di protezione aggiuntivi come fusibili e limitatori di corrente.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-31088d9 elementor-widget elementor-widget-heading\" data-id=\"31088d9\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"with-2-10v\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Controllo tramite 2-10V<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f9a4b34 elementor-widget elementor-widget-image\" data-id=\"f9a4b34\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"703\" height=\"330\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/08\/servo-actuator-first-step-2-10-v.webp\" class=\"attachment-full size-full wp-image-6121\" alt=\"DCL fornitore di servizi di assistenza clienti\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84e4fa9 elementor-widget elementor-widget-text-editor\" data-id=\"84e4fa9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>L&#039;attuatore regola la posizione della valvola in base a una relazione lineare con il segnale di ingresso da 2-10 V:<\/li><li style=\"list-style-type: none;\"><ul><li><strong>2V<\/strong> corrisponde alla valvola completamente chiusa.<\/li><li><strong>10V<\/strong> corrisponde alla valvola completamente aperta.<\/li><\/ul><\/li><li>Se il segnale di ingresso supera o esce dall&#039;intervallo specificato, l&#039;attuatore entra nell&#039; <strong>perdita di segnale<\/strong> modalit\u00e0. In base alle impostazioni dell&#039;utente, l&#039;attuatore azioner\u00e0 la valvola per:<ul><li><strong>Completamente aperto<\/strong>,<\/li><li><strong>Completamente chiuso<\/strong>, O<\/li><li><strong>Mantenere la posizione della valvola<\/strong> dove il segnale si \u00e8 perso.<\/li><\/ul><\/li><\/ul><p><strong>Nota<\/strong>Lo schema elettrico sopra riportato illustra la funzionalit\u00e0 di base di un attuatore modulante (valvola elettrica). Nelle applicazioni reali, \u00e8 opportuno considerare anche dispositivi di protezione aggiuntivi come fusibili e limitatori di corrente.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34530c9 elementor-widget elementor-widget-heading\" data-id=\"34530c9\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"with-bus\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Controllo tramite bus di campo<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2844c33 elementor-widget elementor-widget-heading\" data-id=\"2844c33\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">- Modbus, CAN, Profibus, DeviceNet, Foundation Fieldbus, HART, Ethernet<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e9bd27e elementor-widget elementor-widget-image\" data-id=\"e9bd27e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1075\" height=\"597\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/08\/actuator-with-bus-application.webp\" class=\"attachment-full size-full wp-image-6129\" alt=\"Modulo DCL-Modbus\u3001CAN\u3001Profibus\u3001Ethernet\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a0f2acc elementor-widget elementor-widget-text-editor\" data-id=\"a0f2acc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Il sistema di controllo invia un comando di controllo della posizione all&#039;attuatore tramite il protocollo di comunicazione bus. L&#039;attuatore, quindi, aziona la valvola nella posizione specificata in base al comando ricevuto sul bus.<\/li><li><strong>Se si verifica un errore del bus<\/strong>L&#039;attuatore sposter\u00e0 la valvola in una delle seguenti posizioni in base alle impostazioni dell&#039;utente:<ul><li><strong>Completamente aperto<\/strong>,<\/li><li><strong>Completamente chiuso<\/strong>, O<\/li><li><strong>Mantenere la posizione della valvola<\/strong> al momento dell&#039;errore dell&#039;autobus.<\/li><\/ul><\/li><li>Durante il funzionamento dell&#039;attuatore, se l&#039;alimentazione elettrica viene interrotta, l&#039;attuatore si arresta e la valvola elettrica mantiene la sua posizione attuale.<\/li><\/ul><p><strong>Nota<\/strong>Lo schema elettrico sopra riportato mostra la funzionalit\u00e0 di base di un attuatore modulante (valvola elettrica). Nelle applicazioni pratiche, \u00e8 opportuno considerare anche dispositivi di protezione aggiuntivi come fusibili e limitatori di corrente.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c8901d0 elementor-widget elementor-widget-heading\" data-id=\"c8901d0\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"with-iiot\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Controllo tramite IIoT<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d4b2ca elementor-widget elementor-widget-heading\" data-id=\"3d4b2ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">- NB-IoT, LoRA, LoRaWAN, 4G<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f5d67d elementor-widget elementor-widget-image\" data-id=\"1f5d67d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1142\" height=\"936\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/08\/actuator-iot-application.webp\" class=\"attachment-full size-full wp-image-6132\" alt=\"DCL \u884c\u5668 \u7269\u8054\u7f51\u5e94\u7528\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e97caf9 elementor-widget elementor-widget-text-editor\" data-id=\"e97caf9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><p data-start=\"67\" data-end=\"303\">Tramite la piattaforma IoT dell&#039;attuatore, gli utenti possono inviare comandi di controllo della posizione all&#039;attuatore tramite un computer o un&#039;app per smartphone. Una volta ricevuto il comando dalla piattaforma IoT, l&#039;attuatore aziona la valvola nella posizione specificata.<\/p><\/li><li><p data-start=\"67\" data-end=\"303\">La piattaforma IoT consente inoltre il monitoraggio e la registrazione di fattori critici quali la posizione della valvola dell&#039;attuatore, la coppia, la durata dell&#039;alimentazione, la frequenza di regolazione, ecc., in particolare in scenari applicativi critici per la sicurezza o in condizioni estreme.<\/p><\/li><li><p data-start=\"67\" data-end=\"303\">Inoltre, \u00e8 possibile eseguire la diagnostica dei guasti su attuatori non dotati di funzionalit\u00e0 IoT. Questa applicazione \u00e8 estremamente efficace per il monitoraggio e la risoluzione dei problemi relativi a guasti occasionali negli attuatori.<\/p><\/li><li><p data-start=\"67\" data-end=\"303\">Durante il funzionamento dell&#039;attuatore, se l&#039;alimentazione elettrica viene interrotta, l&#039;attuatore si arresta e la valvola elettrica mantiene la sua posizione attuale.<\/p><\/li><\/ul><p><strong data-start=\"917\" data-end=\"925\">Nota<\/strong>Lo schema elettrico sopra riportato mostra la funzionalit\u00e0 di base di un attuatore modulante (valvola elettrica). Nelle applicazioni pratiche, \u00e8 opportuno considerare anche dispositivi di protezione aggiuntivi come fusibili e limitatori di corrente.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e9bffc5 e-con-full e-flex e-con e-parent\" data-id=\"e9bffc5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-d342722 e-con-full e-flex e-con e-child\" data-id=\"d342722\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-bfc64f0 e-con-full e-flex e-con e-child\" data-id=\"bfc64f0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-fed3052 e-con-full e-flex e-con e-child\" data-id=\"fed3052\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09613e9 elementor-widget elementor-widget-heading\" data-id=\"09613e9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-heading-title elementor-size-default\"><a href=\"\/it\/supporto\/attuatore-2\/perche-lattuatore-elettrico\/\">Precedente: Perch\u00e9 scegliere un attuatore elettrico?<\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fdbc661 e-con-full e-flex e-con e-child\" data-id=\"fdbc661\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6642692 elementor-widget elementor-widget-heading\" data-id=\"6642692\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-heading-title elementor-size-default\"><a href=\"\/it\/supporto\/attuatore-2\/cosa-aziona-lattuatore-dcl\/\">Successivamente: Che tipo di valvole possono essere azionate dagli attuatori elettrici DCL?<\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Once connected to a power supply (AC380V, AC220V, AC24V, or DC24V), DCL electric actuators can be controlled by a Distributed Control System (DCS) using various control signals, including analog signals, digital signals, bus communication, and IoT networks. The actuator drives the electric valve to fully open, fully close, or adjust to a specified position, enabling [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[99],"tags":[],"class_list":["post-10862","post","type-post","status-publish","format-standard","hentry","category-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/it\/wp-json\/wp\/v2\/posts\/10862","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/it\/wp-json\/wp\/v2\/comments?post=10862"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/it\/wp-json\/wp\/v2\/posts\/10862\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/it\/wp-json\/wp\/v2\/media?parent=10862"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/it\/wp-json\/wp\/v2\/categories?post=10862"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/it\/wp-json\/wp\/v2\/tags?post=10862"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}