{"id":9258,"date":"2024-07-05T15:48:31","date_gmt":"2024-07-05T07:48:31","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=9258"},"modified":"2025-03-31T04:29:54","modified_gmt":"2025-03-31T04:29:54","slug":"um-sf-zc-modbus","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/id\/mendukung\/aktuator-um\/um-sf-zc-modbus","title":{"rendered":"Manual Aplikasi Modbus Aktuator DCL (Versi Envision)"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"9258\" class=\"elementor elementor-9258\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-e7e17b5 elementor-section-content-middle elementor-hidden-desktop elementor-hidden-tablet elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e7e17b5\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-5740acb\" data-id=\"5740acb\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-65022da elementor-widget elementor-widget-heading\" data-id=\"65022da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-heading-title elementor-size-default\"><a href=\"\/id\/mendukung\/\">Layanan &amp; Dukungan<\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-5fa23ed\" data-id=\"5fa23ed\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5c2c80c elementor-search-form--skin-classic elementor-search-form--button-type-icon elementor-search-form--icon-search elementor-widget elementor-widget-search-form\" data-id=\"5c2c80c\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;skin&quot;:&quot;classic&quot;}\" data-widget_type=\"search-form.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<search role=\"search\">\n\t\t\t<form class=\"elementor-search-form\" action=\"https:\/\/dclactuator.com\/id\" method=\"get\" data-trp-original-action=\"https:\/\/dclactuator.com\/id\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-search-form__container\">\n\t\t\t\t\t<label class=\"elementor-screen-only\" for=\"elementor-search-form-5c2c80c\">Mencari<\/label>\n\n\t\t\t\t\t\n\t\t\t\t\t<input id=\"elementor-search-form-5c2c80c\" placeholder=\"Mencari...\" class=\"elementor-search-form__input\" type=\"search\" name=\"s\" value=\"\">\n\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t<button class=\"elementor-search-form__submit\" type=\"submit\" aria-label=\"Mencari\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"e-font-icon-svg-container\"><svg class=\"fa fa-search e-font-icon-svg e-fas-search\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M505 442.7L405.3 343c-4.5-4.5-10.6-7-17-7H372c27.6-35.3 44-79.7 44-128C416 93.1 322.9 0 208 0S0 93.1 0 208s93.1 208 208 208c48.3 0 92.7-16.4 128-44v16.3c0 6.4 2.5 12.5 7 17l99.7 99.7c9.4 9.4 24.6 9.4 33.9 0l28.3-28.3c9.4-9.4 9.4-24.6.1-34zM208 336c-70.7 0-128-57.2-128-128 0-70.7 57.2-128 128-128 70.7 0 128 57.2 128 128 0 70.7-57.2 128-128 128z\"><\/path><\/svg><\/div>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/button>\n\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t<input type=\"hidden\" name=\"trp-form-language\" value=\"id\"\/><\/form>\n\t\t<\/search>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-0e9602d elementor-section-content-middle elementor-hidden-desktop elementor-hidden-tablet elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"0e9602d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c2911de\" data-id=\"c2911de\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6709ad5 elementor-widget__width-auto elementor-widget-mobile__width-initial elementor-nav-menu__text-align-aside elementor-nav-menu--toggle elementor-nav-menu--burger elementor-widget elementor-widget-nav-menu\" data-id=\"6709ad5\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;layout&quot;:&quot;dropdown&quot;,&quot;submenu_icon&quot;:{&quot;value&quot;:&quot;&lt;svg class=\\&quot;e-font-icon-svg e-fas-caret-down\\&quot; viewBox=\\&quot;0 0 320 512\\&quot; xmlns=\\&quot;http:\\\/\\\/www.w3.org\\\/2000\\\/svg\\&quot;&gt;&lt;path d=\\&quot;M31.3 192h257.3c17.8 0 26.7 21.5 14.1 34.1L174.1 354.8c-7.8 7.8-20.5 7.8-28.3 0L17.2 226.1C4.6 213.5 13.5 192 31.3 192z\\&quot;&gt;&lt;\\\/path&gt;&lt;\\\/svg&gt;&quot;,&quot;library&quot;:&quot;fa-solid&quot;},&quot;toggle&quot;:&quot;burger&quot;}\" data-widget_type=\"nav-menu.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-toggle\" role=\"button\" tabindex=\"0\" aria-label=\"Menu Toggle\" aria-expanded=\"false\">\n\t\t\t<svg aria-hidden=\"true\" role=\"presentation\" class=\"elementor-menu-toggle__icon--open e-font-icon-svg e-fas-th-large\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M296 32h192c13.255 0 24 10.745 24 24v160c0 13.255-10.745 24-24 24H296c-13.255 0-24-10.745-24-24V56c0-13.255 10.745-24 24-24zm-80 0H24C10.745 32 0 42.745 0 56v160c0 13.255 10.745 24 24 24h192c13.255 0 24-10.745 24-24V56c0-13.255-10.745-24-24-24zM0 296v160c0 13.255 10.745 24 24 24h192c13.255 0 24-10.745 24-24V296c0-13.255-10.745-24-24-24H24c-13.255 0-24 10.745-24 24zm296 184h192c13.255 0 24-10.745 24-24V296c0-13.255-10.745-24-24-24H296c-13.255 0-24 10.745-24 24v160c0 13.255 10.745 24 24 24z\"><\/path><\/svg><svg aria-hidden=\"true\" role=\"presentation\" class=\"elementor-menu-toggle__icon--close e-font-icon-svg e-eicon-close\" viewbox=\"0 0 1000 1000\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M742 167L500 408 258 167C246 154 233 150 217 150 196 150 179 158 167 167 154 179 150 196 150 212 150 229 154 242 171 254L408 500 167 742C138 771 138 800 167 829 196 858 225 858 254 829L496 587 738 829C750 842 767 846 783 846 800 846 817 842 829 829 842 817 846 804 846 783 846 767 842 750 829 737L588 500 833 258C863 229 863 200 833 171 804 137 775 137 742 167Z\"><\/path><\/svg>\t\t<\/div>\n\t\t\t\t\t<nav class=\"elementor-nav-menu--dropdown elementor-nav-menu__container\" aria-hidden=\"true\">\n\t\t\t\t<ul id=\"menu-2-6709ad5\" class=\"elementor-nav-menu\"><li class=\"menu-item menu-item-type-post_type menu-item-object-post menu-item-has-children menu-item-11222\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/aktuator-2\/why-electrical-actuator\" class=\"elementor-item\" tabindex=\"-1\">Mengapa memilih aktuator listrik?<\/a>\n<ul class=\"sub-menu elementor-nav-menu--dropdown\">\n\t<li class=\"menu-item menu-item-type-custom menu-item-object-custom menu-item-9587\"><a href=\"\/id\/mendukung\/aktuator-2\/why-electrical-actuator\/#reliable\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Andal dan Tahan Lama<\/a><\/li>\n\t<li class=\"menu-item menu-item-type-custom menu-item-object-custom menu-item-9588\"><a href=\"\/id\/mendukung\/aktuator-2\/why-electrical-actuator\/#small\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Ringkas dan Hemat Ruang<\/a><\/li>\n\t<li class=\"menu-item menu-item-type-custom menu-item-object-custom menu-item-9589\"><a href=\"\/id\/mendukung\/aktuator-2\/why-electrical-actuator\/#high-efficiency\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Efisiensi Tinggi<\/a><\/li>\n\t<li class=\"menu-item menu-item-type-custom menu-item-object-custom menu-item-9590\"><a href=\"\/id\/mendukung\/aktuator-2\/why-electrical-actuator\/#controllability\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Presisi dan Kontrolabilitas Tinggi<\/a><\/li>\n\t<li class=\"menu-item menu-item-type-custom menu-item-object-custom menu-item-9591\"><a href=\"\/id\/mendukung\/aktuator-2\/why-electrical-actuator\/#usability\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Kemudahan Penggunaan<\/a><\/li>\n\t<li class=\"menu-item menu-item-type-custom menu-item-object-custom menu-item-9592\"><a href=\"\/id\/mendukung\/aktuator-2\/why-electrical-actuator\/#dcl-actuator\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Aktuator Listrik DCL<\/a><\/li>\n<\/ul>\n<\/li>\n<li class=\"menu-item menu-item-type-post_type menu-item-object-post menu-item-has-children menu-item-11223\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/aktuator-2\/cara-kerja-aktuator\" class=\"elementor-item\" tabindex=\"-1\">Bagaimana cara kerja aktuator listrik?<\/a>\n<ul class=\"sub-menu elementor-nav-menu--dropdown\">\n\t<li class=\"sidebar-menu-2nd-level menu-item menu-item-type-custom menu-item-object-custom menu-item-has-children menu-item-9574\"><a href=\"\/id\/mendukung\/aktuator-2\/cara-kerja-aktuator\/#on-off-actuator\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Aktuator ON-OFF<\/a>\n\t<ul class=\"sub-menu elementor-nav-menu--dropdown\">\n\t\t<li class=\"sidebar-menu-3rd-level menu-item menu-item-type-custom menu-item-object-custom menu-item-9575\"><a href=\"\/id\/mendukung\/aktuator-2\/cara-kerja-aktuator\/#with-relay-ac220v\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Ditenagai oleh AC85-265V &amp; Dikendalikan oleh Relay<\/a><\/li>\n\t\t<li class=\"sidebar-menu-3rd-level menu-item menu-item-type-custom menu-item-object-custom menu-item-9577\"><a href=\"\/id\/mendukung\/aktuator-2\/cara-kerja-aktuator\/#with-relay-dc24v\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Ditenagai oleh DC24V &amp; Dikendalikan oleh Relai<\/a><\/li>\n\t\t<li class=\"sidebar-menu-3rd-level menu-item menu-item-type-custom menu-item-object-custom menu-item-9578\"><a href=\"\/id\/mendukung\/aktuator-2\/cara-kerja-aktuator\/#with-switch-ac220v\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Ditenagai oleh AC85-265V &amp; Dikendalikan oleh Saklar<\/a><\/li>\n\t\t<li class=\"sidebar-menu-3rd-level menu-item menu-item-type-custom menu-item-object-custom menu-item-9579\"><a href=\"\/id\/mendukung\/aktuator-2\/cara-kerja-aktuator\/#with-switch-dc24v\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Ditenagai oleh DC24V &amp; Dikendalikan oleh Saklar<\/a><\/li>\n\t<\/ul>\n<\/li>\n\t<li class=\"sidebar-menu-2nd-level menu-item menu-item-type-custom menu-item-object-custom menu-item-has-children menu-item-9576\"><a href=\"\/id\/mendukung\/aktuator-2\/cara-kerja-aktuator\/#modulation-actuator\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Aktuator Modulasi<\/a>\n\t<ul class=\"sub-menu elementor-nav-menu--dropdown\">\n\t\t<li class=\"sidebar-menu-3rd-level menu-item menu-item-type-custom menu-item-object-custom menu-item-9580\"><a href=\"\/id\/mendukung\/aktuator-2\/cara-kerja-aktuator\/#with-4-20ma\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Kontrol melalui 4-20mA<\/a><\/li>\n\t\t<li class=\"sidebar-menu-3rd-level menu-item menu-item-type-custom menu-item-object-custom menu-item-9581\"><a href=\"\/id\/mendukung\/aktuator-2\/cara-kerja-aktuator\/#with-2-10v\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Kontrol melalui 2-10V<\/a><\/li>\n\t\t<li class=\"sidebar-menu-3rd-level menu-item menu-item-type-custom menu-item-object-custom menu-item-9582\"><a href=\"\/id\/mendukung\/aktuator-2\/cara-kerja-aktuator\/#with-bus\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Kontrol melalui fieldbus<\/a><\/li>\n\t\t<li class=\"sidebar-menu-3rd-level menu-item menu-item-type-custom menu-item-object-custom menu-item-9583\"><a href=\"\/id\/mendukung\/aktuator-2\/cara-kerja-aktuator\/#with-iiot\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Kontrol melalui IIoT<\/a><\/li>\n\t<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li class=\"menu-item menu-item-type-post_type menu-item-object-post menu-item-has-children menu-item-11224\"><a href=\"https:\/\/dclactuator.com\/id\/uncategorized\/what-dcl-actuator-drives\" class=\"elementor-item\" tabindex=\"-1\">Jenis katup apa saja yang dapat digerakkan oleh aktuator listrik DCL?<\/a>\n<ul class=\"sub-menu elementor-nav-menu--dropdown\">\n\t<li class=\"sidebar-menu-2nd-level menu-item menu-item-type-custom menu-item-object-custom menu-item-9594\"><a href=\"\/id\/mendukung\/aktuator-2\/what-dcl-actuator-drives\/#butterfly-valve\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Katup kupu-kupu penggerak<\/a><\/li>\n\t<li class=\"sidebar-menu-2nd-level menu-item menu-item-type-custom menu-item-object-custom menu-item-9595\"><a href=\"\/id\/mendukung\/aktuator-2\/what-dcl-actuator-drives\/#ball-valve\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Katup bola penggerak<\/a><\/li>\n\t<li class=\"sidebar-menu-2nd-level menu-item menu-item-type-custom menu-item-object-custom menu-item-9596\"><a href=\"\/id\/mendukung\/aktuator-2\/what-dcl-actuator-drives\/#damper\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Mengoperasikan Peredam Ventilasi dan Katup Penutup Udara<\/a><\/li>\n\t<li class=\"sidebar-menu-2nd-level menu-item menu-item-type-custom menu-item-object-custom menu-item-9600\"><a href=\"\/id\/mendukung\/aktuator-2\/what-dcl-actuator-drives\/#other-valves\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Mengoperasikan jenis katup lainnya<\/a><\/li>\n\t<li class=\"sidebar-menu-2nd-level menu-item menu-item-type-custom menu-item-object-custom menu-item-9599\"><a href=\"\/id\/mendukung\/aktuator-2\/what-dcl-actuator-drives\/#drive-others\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Mengoperasikan perangkat lain<\/a><\/li>\n<\/ul>\n<\/li>\n<li class=\"menu-item menu-item-type-post_type menu-item-object-post menu-item-has-children menu-item-11225\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/aktuator-2\/cara-memilih-aktuator\" class=\"elementor-item\" tabindex=\"-1\">Bagaimana cara memilih aktuator?<\/a>\n<ul class=\"sub-menu elementor-nav-menu--dropdown\">\n\t<li class=\"menu-item menu-item-type-post_type menu-item-object-post menu-item-11226\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/aktuator-sertifikasi\" class=\"elementor-sub-item\" tabindex=\"-1\">Sertifikasi<\/a><\/li>\n\t<li class=\"menu-item menu-item-type-post_type menu-item-object-post menu-item-11227\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/faq-aktuator\" class=\"elementor-sub-item\" tabindex=\"-1\">Pertanyaan yang Sering Diajukan (FAQ)<\/a><\/li>\n<\/ul>\n<\/li>\n<li class=\"menu-item menu-item-type-post_type menu-item-object-post menu-item-has-children menu-item-11228\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/aktuator-2\/installing-and-using\" class=\"elementor-item\" tabindex=\"-1\">Cara Menginstal dan Menggunakan<\/a>\n<ul class=\"sub-menu elementor-nav-menu--dropdown\">\n\t<li class=\"menu-item menu-item-type-post_type menu-item-object-post menu-item-has-children menu-item-11229\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/ug-actuator\/5-steps-to-use-actuator\" class=\"elementor-sub-item\" tabindex=\"-1\">5 Langkah untuk Mulai Menggunakan Aktuator DCL<\/a>\n\t<ul class=\"sub-menu elementor-nav-menu--dropdown\">\n\t\t<li class=\"menu-item menu-item-type-custom menu-item-object-custom menu-item-10828\"><a href=\"\/id\/mendukung\/ug-actuator\/5-steps-to-use-actuator\/#step1\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">1. Pasang aktuator pada katup.<\/a><\/li>\n\t\t<li class=\"menu-item menu-item-type-custom menu-item-object-custom menu-item-10829\"><a href=\"\/id\/mendukung\/ug-actuator\/5-steps-to-use-actuator\/#step2\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">2. Periksa pembatas mekanis<\/a><\/li>\n\t\t<li class=\"menu-item menu-item-type-custom menu-item-object-custom menu-item-10830\"><a href=\"\/id\/mendukung\/ug-actuator\/5-steps-to-use-actuator\/#step3\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">3. Pengkabelan<\/a><\/li>\n\t\t<li class=\"menu-item menu-item-type-custom menu-item-object-custom menu-item-10831\"><a href=\"\/id\/mendukung\/ug-actuator\/5-steps-to-use-actuator\/#step4\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">4. Atur posisi akhir Buka\/Tutup<\/a><\/li>\n\t\t<li class=\"menu-item menu-item-type-custom menu-item-object-custom menu-item-10832\"><a href=\"\/id\/mendukung\/ug-actuator\/5-steps-to-use-actuator\/#step5\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">5. Mulai Menggunakan<\/a><\/li>\n\t<\/ul>\n<\/li>\n\t<li class=\"menu-item menu-item-type-post_type menu-item-object-post menu-item-11230\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/cara-aktuator\" class=\"elementor-sub-item\" tabindex=\"-1\">Cara-cara<\/a><\/li>\n\t<li class=\"menu-item menu-item-type-post_type menu-item-object-post menu-item-11231\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/aktuator-um\" class=\"elementor-sub-item\" tabindex=\"-1\">Panduan Pengguna<\/a><\/li>\n\t<li class=\"menu-item menu-item-type-post_type menu-item-object-post menu-item-11232\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/aktuator\" class=\"elementor-sub-item\" tabindex=\"-1\">Catatan Aplikasi<\/a><\/li>\n<\/ul>\n<\/li>\n<li class=\"menu-item menu-item-type-post_type menu-item-object-post menu-item-has-children menu-item-11233\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/aktuator-mr\" class=\"elementor-item\" tabindex=\"-1\">Pemeliharaan &amp; Perbaikan<\/a>\n<ul class=\"sub-menu elementor-nav-menu--dropdown\">\n\t<li class=\"sidebar-menu-2nd-level menu-item menu-item-type-custom menu-item-object-custom menu-item-has-children menu-item-9604\"><a href=\"#\" class=\"elementor-sub-item elementor-item-anchor\" tabindex=\"-1\">Kesalahan Umum &amp; Pemecahan Masalah<\/a>\n\t<ul class=\"sub-menu elementor-nav-menu--dropdown\">\n\t\t<li class=\"sidebar-menu-3rd-level menu-item menu-item-type-post_type menu-item-object-post menu-item-9698\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/aktuator-mr\/on-off-actuator\" class=\"elementor-sub-item\" tabindex=\"-1\">untuk aktuator ON-OFF<\/a><\/li>\n\t\t<li class=\"sidebar-menu-3rd-level menu-item menu-item-type-post_type menu-item-object-post menu-item-9697\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/aktuator-mr\/modulating-actuator\" class=\"elementor-sub-item\" tabindex=\"-1\">untuk Aktuator Modulasi<\/a><\/li>\n\t\t<li class=\"sidebar-menu-3rd-level menu-item menu-item-type-post_type menu-item-object-post menu-item-9694\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/aktuator-mr\/dcl-gey-24v-modulating\" class=\"elementor-sub-item\" tabindex=\"-1\">untuk Aktuator DC24V<\/a><\/li>\n\t\t<li class=\"sidebar-menu-3rd-level menu-item menu-item-type-post_type menu-item-object-post menu-item-9695\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/aktuator-mr\/dcl-02-on-off-actuator\" class=\"elementor-sub-item\" tabindex=\"-1\">untuk aktuator ON-OFF DCL-02<\/a><\/li>\n\t\t<li class=\"sidebar-menu-3rd-level menu-item menu-item-type-post_type menu-item-object-post menu-item-9696\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/aktuator-mr\/dcl-02-modulating-actuator\" class=\"elementor-sub-item\" tabindex=\"-1\">untuk Aktuator Modulasi DCL-02<\/a><\/li>\n\t<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li class=\"menu-item menu-item-type-post_type menu-item-object-post menu-item-has-children menu-item-11240\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/aktuator-td\" class=\"elementor-item\" tabindex=\"-1\">Dokumen Teknis<\/a>\n<ul class=\"sub-menu elementor-nav-menu--dropdown\">\n\t<li class=\"menu-item menu-item-type-post_type menu-item-object-post menu-item-11241\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/ts-actuator\" class=\"elementor-sub-item\" tabindex=\"-1\">Standar \u2013 ISO\/EU\/GB<\/a><\/li>\n\t<li class=\"menu-item menu-item-type-post_type menu-item-object-post menu-item-11242\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/ta-actuator\" class=\"elementor-sub-item\" tabindex=\"-1\">Artikel Teknis<\/a><\/li>\n<\/ul>\n<\/li>\n<li class=\"menu-item menu-item-type-post_type menu-item-object-post menu-item-11243\"><a href=\"https:\/\/dclactuator.com\/id\/mendukung\/aktuator-2\/tech-inquiry\" class=\"elementor-item\" tabindex=\"-1\">Pertanyaan Teknis<\/a><\/li>\n<\/ul>\t\t\t<\/nav>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-8e2917e elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"8e2917e\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b58c944\" data-id=\"b58c944\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e0a6b8d elementor-widget elementor-widget-text-editor\" data-id=\"e0a6b8d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Aktuator seri DCL mendukung protokol Modbus-RTU. Dengan merujuk pada manual aplikasi ini, Anda dapat menghubungkan aktuator DCL ke Modbus.<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-medium\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/actuator-with-bus-application.webp\" width=\"1075\" height=\"597\" \/><\/p><h1><strong>Deskripsi Panel<\/strong><\/h1><p><img decoding=\"async\" class=\"alignleft\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/um\/images\/\/sf-lc-mb-panel.webp\" alt=\"\" width=\"367\" height=\"240\" \/>\u00a0 <img decoding=\"async\" class=\"alignnone\" src=\"https:\/\/dclcontrols.com\/dam\/um\/images\/\/sf-zc-mb-panel.webp\" width=\"369\" height=\"222\" \/><\/p><h2><strong>1. Definisi Antarmuka<\/strong><\/h2><ul><li><p><strong>P1:<\/strong> 220VAC Netral (N)<\/p><\/li><li><p><strong>P2:<\/strong> 220VAC Live (L)<\/p><\/li><li><p><strong>P3:<\/strong> Input 4-20mA \u2013<\/p><\/li><li><p><strong>P4:<\/strong> Input 4-20mA +<\/p><\/li><li><p><strong>P5:<\/strong> Output 4-20mA \u2013<\/p><\/li><li><p><strong>Halaman 6:<\/strong> Output 4-20mA +<\/p><\/li><li><p><strong>Halaman 7:<\/strong> RS485 A<\/p><\/li><li><p><strong>Halaman 8:<\/strong> RS485 B<\/p><\/li><\/ul><h2><strong>2. Tombol<\/strong><\/h2><ul><li><p><strong>Membuka:<\/strong> Dalam \u201cMode Pengaturan\u201d (ketika sakelar SA menunjuk ke \u201c2\u201d), menekan tombol ini akan membuka aktuator, dan melepaskannya akan menghentikan motor. Menekan <strong>Mengatur<\/strong> Dan <strong>Membuka<\/strong> digunakan secara bersamaan untuk kalibrasi posisi terbuka penuh.<\/p><\/li><li><p><strong>Ditutup:<\/strong> Dalam \u201cMode Pengaturan,\u201d menekan tombol ini akan menutup aktuator, dan melepaskannya akan menghentikan motor. Menekan <strong>Mengatur<\/strong> Dan <strong>Ditutup<\/strong> digunakan secara bersamaan untuk kalibrasi posisi penutupan penuh.<\/p><\/li><li><p><strong>Mengatur:<\/strong> Digunakan dalam kombinasi dengan <strong>Membuka<\/strong> Dan <strong>Ditutup<\/strong> dalam \u201cMode Pengaturan\u201d untuk melakukan fungsi-fungsi tertentu.<\/p><\/li><\/ul><h2><strong>3. Sakelar Pemilih<\/strong><\/h2><ul><li><p><strong>SA:<\/strong> Memilih mode aksi langsung\/terbalik sinyal input dan status pengaturan. Pengaturan ini harus dilakukan saat perangkat dinyalakan agar efektif. Pengaturan default pabrik adalah <strong>1<\/strong>:<\/p><ul><li><p><strong>1 \u2013 Aksi Langsung<\/strong><\/p><\/li><li><p><strong>2 \u2013 Mode Pengaturan<\/strong><\/p><\/li><li><p><strong>3 \u2013 Aksi Balik<\/strong><\/p><\/li><\/ul><\/li><li><p><strong>SB:<\/strong> Mengatur posisi aman. Saat sinyal kontrol eksternal hilang, aktuator bergerak ke posisi yang ditentukan. Pengaturan default pabrik adalah <strong>2<\/strong>:<\/p><ul><li><p><strong>1 \u2013 Beralih ke Mode Terbuka Penuh<\/strong><\/p><\/li><li><p><strong>2 \u2013 Pertahankan Posisi Saat Ini<\/strong><\/p><\/li><li><p><strong>3 \u2013 Pindah ke Penutupan Penuh<\/strong><\/p><\/li><\/ul><p><strong>Catatan:<\/strong> Saat menggunakan kontrol Modbus, <strong>SB harus diatur ke posisi 2.<\/strong><\/p><\/li><\/ul><h2><strong>4. Potensiometer Penyesuaian Nilai Deadband<\/strong><\/h2><ul><li><p>Mengatur nilai deadband. Memutar searah jarum jam meningkatkan deadband; memutar berlawanan arah jarum jam menurunkannya. Rentangnya adalah <strong>0.5% &#8211; 5.0%<\/strong> (pengaturan pabrik default adalah) <strong>1.5%<\/strong>).<\/p><\/li><\/ul><h2><strong>5. Lampu Indikator<\/strong><\/h2><ul><li><p><strong>L1 (Hijau):<\/strong> Indikator Daya \u2013 Menyala saat daya teraliri.<\/p><\/li><li><p><strong>L2 (Merah):<\/strong> Indikator Kegagalan Sinyal Input \u2013 Menyala ketika sinyal input gagal.<\/p><\/li><li><p><strong>L3 (Merah):<\/strong> Indikator Kegagalan Deteksi Posisi \u2013 Menyala jika potensiometer posisi terbuka, korsleting, atau rusak.<\/p><\/li><li><p><strong>L4 (Merah):<\/strong> Indikator Kegagalan Pengacakan \u2013 Menyala saat terjadi pengacakan.<\/p><\/li><\/ul><h2>\u00a0<\/h2><h1><strong>Pengaturan<\/strong><\/h1><p>Untuk masuk ke \u201cMode Pengaturan,\u201d atur <strong>SA<\/strong> untuk memposisikan <strong>2<\/strong>Mode ini memungkinkan:<\/p><ul><li><p>Kalibrasi perjalanan<\/p><\/li><li><p>Penanganan kegagalan sinyal input<\/p><\/li><li><p>Penyesuaian nilai deadband<\/p><\/li><li><p>Pengoperasian manual<\/p><\/li><li><p>Kalibrasi arus keluaran<\/p><\/li><\/ul><h2><strong>1. Mengatur Posisi Akhir<\/strong><\/h2><ul><li><p><strong>Mengatur posisi akhir penutupan:<\/strong> Atur katup ke posisi tertutup sepenuhnya menggunakan <strong>Membuka<\/strong> dan\/atau <strong>Ditutup<\/strong> tombol. Tekan <strong>Mengatur<\/strong>, Kemudian <strong>Ditutup<\/strong>, dan tahan keduanya selama kurang lebih <strong>4 detik<\/strong> sampai <strong>Lampu L2 menyala<\/strong>, lalu lepaskan kedua tombol tersebut. <strong>L2 mati, menandakan pengaturan telah selesai.<\/strong><\/p><\/li><li><p><strong>Mengatur posisi akhir pembukaan:<\/strong> Atur katup ke posisi terbuka penuh menggunakan <strong>Membuka<\/strong> dan\/atau <strong>Ditutup<\/strong> tombol. Tekan <strong>Mengatur<\/strong>, Kemudian <strong>Membuka<\/strong>, dan tahan keduanya selama kurang lebih <strong>4 detik<\/strong> sampai <strong>Lampu L2 menyala<\/strong>, lalu lepaskan kedua tombol tersebut. <strong>L2 mati, menandakan pengaturan telah selesai.<\/strong><\/p><\/li><\/ul><h2><strong>2. Mengatur Alamat Modbus<\/strong><\/h2><ul><li><p>Alamat komunikasi Modbus dan kecepatan baud dapat dimodifikasi melalui perintah Modbus.<\/p><\/li><li><p>Alamat default pabrik: <strong>1<\/strong><\/p><\/li><li><p>Kecepatan baud default pabrik: <strong>9600<\/strong><\/p><\/li><\/ul><h2><strong>3. Penyesuaian Nilai Deadband<\/strong><\/h2><ul><li><p>Memutar potensiometer <strong>searah jarum jam<\/strong> meningkatkan deadband.<\/p><\/li><li><p>Memutarnya <strong>berlawanan arah jarum jam<\/strong> mengurangi deadband.<\/p><\/li><li><p><strong>Setiap tanda centang sesuai dengan perubahan 0,5%.<\/strong><\/p><\/li><li><p>Jika diatur di bawah ini <strong>0.5%<\/strong>, ini diproses secara otomatis sebagai <strong>0.5%<\/strong>.<\/p><\/li><li><p>Di dalam <strong>Mode Pengaturan<\/strong>, menggunakan <strong>Membuka<\/strong> atau <strong>Ditutup<\/strong> untuk membuka atau menutup katup secara manual.<\/p><\/li><\/ul><h1>\u00a0<\/h1><h1><strong>Operasi<\/strong><\/h1><p>Untuk memulai pengoperasian otomatis, atur <strong>SA<\/strong> untuk memposisikan <strong>1<\/strong> atau <strong>3<\/strong>.<\/p><ul><li><p>Saat dinyalakan, aktuator secara default akan <strong>Kontrol sinyal 4-20mA<\/strong>.<\/p><\/li><li><p>Mengirimkan perintah Modbus akan mengaktifkan aktuator. <strong>mode kontrol komunikasi<\/strong>.<\/p><\/li><li><p>Setelah melakukan siklus daya, aktuator kembali ke <strong>mode kontrol analog<\/strong>.<\/p><\/li><\/ul><p><strong>Penting:<\/strong> Saat menggunakan kontrol Modbus:<\/p><ul><li><p>Memastikan <strong>SB ditempatkan di posisi 2<\/strong>.<\/p><\/li><li><p>Setiap perintah kontrol harus mencakup hal-hal berikut: <strong>mode kontrol dan nilai posisi<\/strong> untuk mencegah tindakan yang tidak diinginkan setelah memulai ulang.<\/p><\/li><\/ul><h2><strong>Menggunakan arus 4-20mA untuk kontrol posisi.<\/strong><\/h2><table><thead><tr><th>Sinyal Masukan<\/th><th>4mA<\/th><th>8mA<\/th><th>12mA<\/th><th>16mA<\/th><th>20mA<\/th><\/tr><\/thead><tbody><tr><td>Posisi Penunjuk<\/td><td>TUTUP (0)<\/td><td>2.5<\/td><td>5<\/td><td>7.5<\/td><td>BUKA (100)<\/td><\/tr><tr><td>Pembukaan Katup (%)<\/td><td>0%<\/td><td>25%<\/td><td>50%<\/td><td>75%<\/td><td>100%<\/td><\/tr><tr><td>Sinyal Keluaran<\/td><td>4mA<\/td><td>8mA<\/td><td>12mA<\/td><td>16mA<\/td><td>20mA<\/td><\/tr><\/tbody><\/table><p><strong>Catatan:<\/strong><\/p><ul><li><p>Di dalam <strong>mode aksi terbalik<\/strong>, <strong>4mA sesuai dengan 100% terbuka<\/strong>, Dan <strong>20mA sesuai dengan 0% terbuka<\/strong>.<\/p><\/li><li><p>Tingkat akurasi pengontrol servo: <strong>\u00b11%<\/strong><\/p><\/li><li><p>Histeresis: <strong>&lt;1%<\/strong><\/p><\/li><\/ul><h2><strong>Menggunakan Modbus untuk Mengontrol Posisi Aktuator<\/strong><\/h2><h3><strong>Lapisan Fisik<\/strong><\/h3><p>Aktuator DCL mendukung <strong>Modbus-RTU<\/strong> protokol dan menggunakannya <strong>Antarmuka RS485<\/strong> pada lapisan fisik.<\/p><ul><li><p><strong>Alamat Komunikasi:<\/strong> Dapat dikonfigurasi dari <strong>1 sampai 127<\/strong>, defaultnya adalah <strong>1<\/strong>.<\/p><\/li><li><p><strong>Kecepatan Baud:<\/strong> Dapat dikonfigurasi, defaultnya adalah <strong>115200<\/strong>.<\/p><\/li><li><p><strong>Format Port Serial:<\/strong> <strong>1 bit awal + 8 bit data + 1 bit berhenti<\/strong>.<\/p><\/li><li><p><strong>Fungsi Siaran:<\/strong> Didukung.<\/p><\/li><\/ul><h3><strong>Definisi Antarmuka<\/strong><\/h3><p><img decoding=\"async\" class=\"alignleft\" src=\"https:\/\/www.dcl-controls.com\/content\/dam\/um\/images\/\/sf-lc-mb-panel.webp\" alt=\"\" width=\"367\" height=\"240\" \/>\u00a0 <img decoding=\"async\" class=\"alignnone\" src=\"https:\/\/dclcontrols.com\/dam\/um\/images\/\/sf-zc-mb-panel.webp\" width=\"369\" height=\"222\" \/><\/p><table><thead><tr><th>Pin<\/th><th>Fungsi<\/th><\/tr><\/thead><tbody><tr><td>P1<\/td><td>Kekuatan (-)<\/td><\/tr><tr><td>Halaman 2<\/td><td>Daya (+)<\/td><\/tr><tr><td>Halaman 7<\/td><td>RS485 A<\/td><\/tr><tr><td>Halaman 8<\/td><td>RS485 B<\/td><\/tr><tr><td>P3~P6<\/td><td>Dikhususkan untuk sinyal analog (4)<del>20mA \/ 0<\/del>10V)<\/td><\/tr><\/tbody><\/table><h3><strong>Diagram Pengkabelan Modbus<\/strong><\/h3><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/um\/images\/\/sf-zc-mb-connection.webp\" width=\"1910\" height=\"456\" \/><\/p><h3><strong>Lapisan Aplikasi<\/strong><\/h3><h4><strong>1. ADU (Unit Data Aplikasi)<\/strong><\/h4><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/wp-content\/uploads\/2023\/08\/modbus-adu.webp\" width=\"689\" height=\"130\" \/><\/p><h4><strong>2. Kode Fungsi<\/strong><\/h4><table><thead><tr><th>PENGENAL<\/th><th>Nama<\/th><th>Keterangan<\/th><\/tr><\/thead><tbody><tr><td>0x03<\/td><td>Membaca Beberapa Register<\/td><td>Membaca blok register penyimpanan dari perangkat jarak jauh.<\/td><\/tr><tr><td>0x06<\/td><td>Tulis Register Tunggal<\/td><td>Menulis satu register pada perangkat jarak jauh.<\/td><\/tr><tr><td>0x10<\/td><td>Tulis ke Beberapa Register<\/td><td>Menuliskan blok register berurutan (1 hingga sekitar 120 register).<\/td><\/tr><\/tbody><\/table><h4><strong>3. Mengonfigurasi Parameter Komunikasi<\/strong><\/h4><p>Daftar <strong>0x0040 \u2013 0x0042<\/strong> digunakan untuk <strong>pengaturan komunikasi<\/strong>:<\/p><ol><li><p>Menulis <strong>0xA501<\/strong> untuk mendaftar <strong>0x0040<\/strong> untuk masuk <strong>mode konfigurasi<\/strong>.<\/p><\/li><li><p>Memodifikasi <strong>register 0x0041<\/strong> (alamat komunikasi) dan <strong>register 0x0042<\/strong> (kecepatan baud).<\/p><\/li><li><p>Parameter baru tersebut mulai berlaku dalam waktu... <strong>1 detik<\/strong>, dan komunikasi selanjutnya harus menggunakan pengaturan yang telah diperbarui.<\/p><\/li><li><p>Keluar dari mode konfigurasi dengan menulis <strong>0x0000<\/strong> ke <strong>register 0x0040<\/strong>.<\/p><\/li><\/ol><h4><strong>4. Memaksa Mode Komunikasi Default<\/strong><\/h4><ol><li><p>Mengatur <strong>SA<\/strong> ke <strong>posisi 2<\/strong> Dan <strong>SB<\/strong> ke <strong>posisi 2<\/strong>.<\/p><\/li><li><p>Tekan dan tahan <strong>Tombol KS<\/strong> selama sekitar <strong>3 detik<\/strong> sampai <strong>lampu merah berkedip<\/strong>lalu lepaskan tombolnya.<\/p><\/li><li><p>Tekan dan tahan <strong>Tombol KC<\/strong> selama sekitar <strong>3 detik<\/strong> sampai <strong>lampu merah tetap menyala<\/strong>lalu lepaskan tombolnya.<\/p><\/li><li><p>Parameter komunikasi sekarang adalah <strong>kembalikan ke nilai default<\/strong>.<\/p><\/li><li><p>Mengatur <strong>SA<\/strong> kembali ke <strong>posisi 1<\/strong> untuk keluar dari mode ini.<\/p><\/li><li><p>Pengaturan baru tetap berlaku. <strong>bahkan setelah me-restart perangkat<\/strong>.<\/p><\/li><\/ol><p><strong>Catatan:<\/strong><br \/>Jika Anda lupa parameter komunikasi sebelumnya, gunakan metode ini untuk mengembalikan mode komunikasi default dan mengkonfigurasi ulang pengaturan komunikasi.<\/p><h3><strong>Daftar Registrasi<\/strong><\/h3><table><thead><tr><th>Alamat Terdaftar<\/th><th>Potongan<\/th><th>Kelompok<\/th><th>Nama Sinyal<\/th><th>Nilai Minimum<\/th><th>Nilai Maksimum<\/th><th>Satuan<\/th><th>Baca\/Tulis<\/th><th>Jenis<\/th><th>Keterangan<\/th><\/tr><\/thead><tbody><tr><td><strong>0x0010<\/strong><\/td><td><strong>b15-b5<\/strong><\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>r\/w<\/td><td>heksadesimal<\/td><td>Dicadangkan (0)<\/td><\/tr><tr><td><strong>b4<\/strong><\/td><td><strong>kontrol<\/strong><\/td><td>Berhenti<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>r\/w<\/td><td>heksadesimal<\/td><td>1: Berhenti, 0: Operasi normal<\/td><\/tr><tr><td><strong>b1-b0<\/strong><\/td><td><strong>kontrol<\/strong><\/td><td>Mode<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>r\/w<\/td><td>heksadesimal<\/td><td>1: Kontrol komunikasi, lainnya: Keluar dari kontrol komunikasi<\/td><\/tr><tr><td><strong>0x0011<\/strong><\/td><td><strong>b15-b0<\/strong><\/td><td><strong>kontrol<\/strong><\/td><td>Atur Derajat Terbuka<\/td><td>0<\/td><td>10000<\/td><td>%<\/td><td>r\/w<\/td><td>int\/hex<\/td><td>0-10000 sesuai dengan bukaan katup 0-100% (faktor skala: 1\/100)<\/td><\/tr><tr><td><strong>0x0018<\/strong><\/td><td><strong>b15-b6<\/strong><\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>R<\/td><td>heksadesimal<\/td><td>Dicadangkan (0)<\/td><\/tr><tr><td><strong>b5<\/strong><\/td><td><strong>informasi<\/strong><\/td><td>Posisi kesalahan<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>R<\/td><td>heksadesimal<\/td><td>1: Kegagalan sinyal posisi<\/td><\/tr><tr><td><strong>b4<\/strong><\/td><td><strong>informasi<\/strong><\/td><td>sinyal kesalahan<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>R<\/td><td>heksadesimal<\/td><td>1: Kegagalan sinyal masukan<\/td><\/tr><tr><td><strong>b3<\/strong><\/td><td><strong>informasi<\/strong><\/td><td>Bendera Torsi berlebih<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>R<\/td><td>heksadesimal<\/td><td>1: Terdeteksi kelebihan beban<\/td><\/tr><tr><td><strong>b2<\/strong><\/td><td><strong>informasi<\/strong><\/td><td>Bendera macet<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>R<\/td><td>heksadesimal<\/td><td>1: Gangguan terdeteksi<\/td><\/tr><tr><td><strong>b1<\/strong><\/td><td><strong>informasi<\/strong><\/td><td>openRunFlag<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>R<\/td><td>heksadesimal<\/td><td>1: Membuka katup<\/td><\/tr><tr><td><strong>b0<\/strong><\/td><td><strong>informasi<\/strong><\/td><td>tutupRunFlag<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>R<\/td><td>heksadesimal<\/td><td>1: Menutup katup<\/td><\/tr><tr><td><strong>0x0019<\/strong><\/td><td><strong>b15-b0<\/strong><\/td><td><strong>informasi<\/strong><\/td><td>Gelar terbuka<\/td><td>0<\/td><td>10000<\/td><td>%<\/td><td>R<\/td><td>int\/hex<\/td><td>0-10000 sesuai dengan bukaan katup 0-100% (faktor skala: 1\/100)<\/td><\/tr><tr><td><strong>0x0040<\/strong><\/td><td><strong>b15-b0<\/strong><\/td><td><strong>konfigurasi<\/strong><\/td><td>cfgMode<\/td><td>1<\/td><td>127<\/td><td>&#8211;<\/td><td>rw<\/td><td>heksadesimal<\/td><td>0x0000: Mode normal, 0xA501: Mode konfigurasi<\/td><\/tr><tr><td><strong>0x0041<\/strong><\/td><td><strong>b15-b0<\/strong><\/td><td><strong>konfigurasi<\/strong><\/td><td>cmm_addr<\/td><td>1<\/td><td>127<\/td><td>&#8211;<\/td><td>rw<\/td><td>heksadesimal<\/td><td>Menetapkan alamat komunikasi<\/td><\/tr><tr><td><strong>0x0042<\/strong><\/td><td><strong>b15-b0<\/strong><\/td><td><strong>konfigurasi<\/strong><\/td><td>kecepatan baud cmm<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>rw<\/td><td>heksadesimal<\/td><td>0: 4800 baud, 1: 9600 baud, 2: 19200 baud, 3: 115200 baud<\/td><\/tr><\/tbody><\/table><h3><strong>Contoh Perintah Komunikasi<\/strong><\/h3><h4><strong>1. Posisi Katup Kontrol<\/strong><\/h4><p><strong>Memasuki Mode Kontrol Komunikasi:<\/strong><br \/>Kirim \u2192 <code>\u25c701 10 00 10 00 01 02 00 01 65 00<\/code><br \/>Terima \u2190 <code>\u25c601 10 00 10 00 01 00 0C<\/code><\/p><p><strong>Pengaturan Posisi Katup: 0%<\/strong><br \/>Kirim \u2192 <code>\u25c701 10 00 11 00 01 02 00 00 A5 11<\/code><br \/>Terima \u2190 <code>\u25c601 10 00 11 00 01 51 CC<\/code><\/p><p><strong>Pengaturan Posisi Katup: 50% (5000 \u2192 0x1388)<\/strong><br \/>Kirim \u2192 <code>\u25c701 10 00 11 00 01 02 13 88 A8 47<\/code><br \/>Terima \u2190 <code>\u25c601 10 00 11 00 01 51 CC<\/code><\/p><p><strong>Pengaturan Posisi Katup: 100% (10000 \u2192 0x2710)<\/strong><br \/>Kirim \u2192 <code>\u25c701 10 00 11 00 01 02 27 10 BF 2D<\/code><br \/>Terima \u2190 <code>\u25c601 10 00 11 00 01 51 CC<\/code><\/p><p><strong>Penghentian Operasi<\/strong><br \/>Kirim \u2192 <code>\u25c701 10 00 10 00 01 02 00 11 64 CC<\/code><br \/>Terima \u2190 <code>\u25c601 10 00 10 00 01 00 0C<\/code><\/p><h4>\u00a0<\/h4><p><strong>2. Baca Status Katup<\/strong><\/p><p>Kirim \u2192 <code>\u25c701 03 00 18 00 02 44 0C<\/code><br \/>Terima \u2190 <code>\u25c601 03 04 00 30 00 00 FA 3C<\/code><\/p><h3>\u00a0<\/h3><h4><strong>3. Atur Alamat Komunikasi<\/strong><\/h4><p><strong>Memasuki Mode Konfigurasi:<\/strong><br \/>Kirim \u2192 <code>\u25c701 10 00 40 00 01 02 A5 01 12 00<\/code><br \/>Terima \u2190 <code>\u25c601 10 00 40 00 01 00 1D<\/code><\/p><p><strong>Ubah Alamat Komunikasi menjadi: 2<\/strong><br \/>Kirim \u2192 <code>\u25c701 10 00 41 00 01 02 00 02 28 80<\/code><br \/>Terima \u2190 <code>\u25c601 10 00 41 00 01 51 DD<\/code><\/p><p><strong>Keluar dari Mode Konfigurasi:<\/strong><br \/>Kirim \u2192 <code>\u25c702 10 00 40 00 01 02 A5 00 C7 30<\/code><br \/>Terima \u2190 <code>\u25c602 10 00 40 00 01 00 2E<\/code><\/p><h3>\u00a0<\/h3><h4><strong>4. Atur Kecepatan Baud Komunikasi<\/strong><\/h4><p><strong>Memasuki Mode Konfigurasi:<\/strong><br \/>Kirim \u2192 <code>\u25c701 10 00 40 00 01 02 A5 01 12 00<\/code><br \/>Terima \u2190 <code>\u25c601 10 00 40 00 01 00 1D<\/code><\/p><p><strong>Ubah Baud Rate menjadi: 9600<\/strong><br \/>Kirim \u2192 <code>\u25c701 10 00 42 00 01 02 00 01 68 B2<\/code><br \/>Terima \u2190 <code>\u25c601 10 00 42 00 01 A1 DD<\/code><\/p><p><strong>Keluar dari Mode Konfigurasi:<\/strong><br \/>Kirim \u2192 <code>\u25c701 10 00 40 00 01 02 A5 00 D3 C0<\/code><br \/>Terima \u2190 <code>\u25c601 10 00 40 00 01 00 1D<\/code><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Service &amp; Support The DCL series actuators support the Modbus-RTU protocol. By referring to this application manual, you can connect the DCL actuator to Modbus. Panel Description \u00a0 1. Interface Definition P1: 220VAC Neutral (N) P2: 220VAC Live (L) P3: 4-20mA Input &#8211; P4: 4-20mA Input + P5: 4-20mA Output &#8211; P6: 4-20mA Output + [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[9],"tags":[],"class_list":["post-9258","post","type-post","status-publish","format-standard","hentry","category-um-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/id\/wp-json\/wp\/v2\/posts\/9258","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/id\/wp-json\/wp\/v2\/comments?post=9258"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/id\/wp-json\/wp\/v2\/posts\/9258\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/id\/wp-json\/wp\/v2\/media?parent=9258"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/id\/wp-json\/wp\/v2\/categories?post=9258"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/id\/wp-json\/wp\/v2\/tags?post=9258"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}