{"id":6034,"date":"2023-08-03T20:40:54","date_gmt":"2023-08-03T12:40:54","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6034"},"modified":"2025-03-27T09:36:11","modified_gmt":"2025-03-27T09:36:11","slug":"dcl-02-modulating-actuator","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/hr\/podrska\/gospodin-aktuator\/dcl-02-modulirajuci-aktuator","title":{"rendered":"Uobi\u010dajene gre\u0161ke i rje\u0161avanje problema za moduliraju\u0107e aktuatore DCL-02"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6034\" class=\"elementor elementor-6034\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4d0a73a e-con-full e-flex e-con e-parent\" data-id=\"4d0a73a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-074db40 e-con-full e-flex e-con e-child\" data-id=\"074db40\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c0eba31 elementor-widget elementor-widget-text-editor\" data-id=\"c0eba31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ovaj vodi\u010d se odnosi na DCL ultra male moduliraju\u0107e aktuatore, model kako slijedi:<\/p><p>DCL-02E<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-baf5aaf elementor-widget elementor-widget-image\" data-id=\"baf5aaf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-02-valve.webp\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4622d9 elementor-widget elementor-widget-heading\" data-id=\"b4622d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Uobi\u010dajeni kvarovi i metode rje\u0161avanja problema<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e06e825 elementor-widget elementor-widget-text-editor\" data-id=\"e06e825\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>\u00a0<\/h3><table><thead><tr><th><strong>Raskrs<\/strong><\/th><th><strong>Mogu\u0107i uzrok<\/strong><\/th><th><strong>Metoda rje\u0161avanja problema<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>Pogon se ne otvara ili zatvara pri pokretanju<\/strong><\/td><td>1. Neispravno o\u017ei\u010denje<\/td><td>Provjerite o\u017ei\u010denje prema dijagramu o\u017ei\u010denja aktuatora kako biste potvrdili da je ispravno.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Neispravno napajanje<\/td><td>Provjerite je li izlazni napon napajanja unutar \u00b110% nazivnog napona aktuatora, a struja je 3 puta ve\u0107a od nazivne struje aktuatora.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Neispravan upravlja\u010dki prekida\u010d ili relej<\/td><td>Izmjerite ulazni napon na upravlja\u010dkom priklju\u010dku sklopke aktuatora multimetrom kako biste bili sigurni da odgovara o\u010dekivanoj vrijednosti.<\/td><\/tr><tr><td>\u00a0<\/td><td>4. Neuskla\u0111enost sustava upravljanja<\/td><td>Za testiranje funkcionalnosti aktuatora upotrijebite mehani\u010dki prekida\u010d. Ako aktuator ispravno radi, provjerite logiku izlaza upravlja\u010dkog sustava.<\/td><\/tr><tr><td>\u00a0<\/td><td>5. Vi\u0161estruki aktuatori ili paralelna veza aktuatora s drugim ure\u0111ajima<\/td><td>Pogoni s prekida\u010dem zapo\u010dinju s kondenzatorom. Paralelno spajanje s drugim ure\u0111ajima utjecat \u0107e na vrijednost kondenzatora. Pogoni s prekida\u010dem trebaju koristiti samo jednostruko upravljanje, a ne paralelno upravljanje.<\/td><\/tr><tr><td><strong>Pogon se mo\u017ee samo otvoriti ili zatvoriti<\/strong><\/td><td>1. Neispravno o\u017ei\u010denje<\/td><td>1. Upotrijebite mehani\u010dki prekida\u010d za testiranje funkcionalnosti aktuatora. Ako radi ispravno, provjerite logiku izlaza upravlja\u010dkog sustava.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. Provjerite o\u017ei\u010denje prema shemu o\u017ei\u010denja aktuatora.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Nepravilna postavka grebena za potpuno otvaranje\/potpuno zatvaranje<\/td><td>Za pravilno pozicioniranje grebenaste osovine pogledajte &quot;Kako postaviti elektri\u010dne ventile s prekida\u010dem&quot;.<\/td><\/tr><tr><td><strong>Pogon se zaustavlja usred hoda<\/strong><\/td><td>1. Zaglavljivanje ventila<\/td><td>Provjerite je li ventil zaglavljen, uklonite blokadu i poku\u0161ajte ponovno nakon \u0161to se za\u0161tita od preoptere\u0107enja aktuatora ohladi.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. \u010cvrste \u010destice u teku\u0107ini uzrokuju zaglavljivanje ventila<\/td><td>Provjerite uzrokuju li krute \u010destice u teku\u0107ini zaglavljivanje ventila, otklonite blokadu i poku\u0161ajte ponovno nakon \u0161to se za\u0161tita od preoptere\u0107enja aktuatora ohladi.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Neispravna postavka blokade za potpuno otvaranje\/potpuno zatvaranje<\/td><td>Za pravilno pode\u0161avanje polo\u017eaja grani\u010dnika pogledajte \u201eKako postaviti elektri\u010dne ventile s prekida\u010dem\u201c.<\/td><\/tr><tr><td><strong>Ne mo\u017ee se okretati aktuator pomo\u0107u ru\u010dke<\/strong><\/td><td>1. \u010cvrste \u010destice u teku\u0107ini uzrokuju blokiranje ventila<\/td><td>Provjerite uzrokuju li \u010dvrste \u010destice blokiranje ventila, otklonite blokadu i poku\u0161ajte ponovno nakon \u0161to se za\u0161tita od preoptere\u0107enja aktuatora ohladi.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Ventil je zaglavljen<\/td><td>Provjerite je li ventil zaglavljen, uklonite blokadu i poku\u0161ajte ponovno nakon \u0161to se za\u0161tita od preoptere\u0107enja aktuatora ohladi.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Mehanizam usporavanja aktuatora o\u0161te\u0107en<\/td><td>Skinite aktuator s ventila i okrenite ru\u010dku. Ako se ne okre\u0107e, zamijenite ga novim aktuatorom.<\/td><\/tr><tr><td><strong>Nema izlaza iz signala povratne informacije o polo\u017eaju<\/strong><\/td><td>1. Neispravno o\u017ei\u010denje prekida\u010da<\/td><td>Provjerite o\u017ei\u010denje prema shemu o\u017ei\u010denja aktuatora kako biste potvrdili da je ispravno.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Nepravilna postavka grebena za potpuno otvaranje\/potpuno zatvaranje<\/td><td>Za pravilno pode\u0161avanje polo\u017eaja grebenaste osovine pogledajte \u201eKako postaviti elektri\u010dne ventile s prekida\u010dem\u201c.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Prekomjerna struja uzrokuje kvar prekida\u010da povratne veze polo\u017eaja<\/td><td>1. Pogledajte \u201eKako postaviti elektri\u010dne ventile s prekida\u010dem\u201c kako biste provjerili priti\u0161\u0107e li greben za potpuno otvaranje\/potpuno zatvaranje ispravno prekida\u010d za povratnu informaciju o polo\u017eaju.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. Izmjerite je li strujni krug povratne veze polo\u017eaja spojen.<\/td><\/tr><\/tbody><\/table><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6802156 elementor-widget elementor-widget-heading\" data-id=\"6802156\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2. Provjerite uvjete primjene radi kompatibilnosti<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be9bb57 elementor-widget elementor-widget-text-editor\" data-id=\"be9bb57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5234\" data-end=\"5479\">Elektri\u010dni aktuatori mogu otkazati ako se koriste nepravilno ili u neispravnim uvjetima primjene. Osiguravanje da aktuator radi unutar specifikacija definiranih u tehni\u010dkom listu proizvoda pomo\u0107i \u0107e u osiguravanju dugotrajnog rada bez problema.<\/p><ul data-start=\"5481\" data-end=\"6708\" data-is-only-node=\"\"><li class=\"\" data-start=\"5481\" data-end=\"5667\"><p class=\"\" data-start=\"5483\" data-end=\"5667\"><strong data-start=\"5483\" data-end=\"5507\">Napon napajanja<\/strong>Napon iz napajanja mora biti unutar nazivnog raspona radnog napona aktuatora. Previsok ili prenizak napon mo\u017ee smanjiti vijek trajanja aktuatora.<\/p><\/li><li class=\"\" data-start=\"5671\" data-end=\"5866\"><p class=\"\" data-start=\"5673\" data-end=\"5866\"><strong data-start=\"5673\" data-end=\"5697\">Struja napajanja<\/strong>Budu\u0107i da je po\u010detna struja motora znatno ve\u0107a od nazivne struje, provjerite da napajanje ima barem 3 puta ve\u0107u nazivnu strujnu snagu aktuatora.<\/p><\/li><li class=\"\" data-start=\"5868\" data-end=\"6082\"><p class=\"\" data-start=\"5870\" data-end=\"6082\"><strong data-start=\"5870\" data-end=\"5885\">Temperatura<\/strong>Osigurajte da aktuator radi unutar nazivnog temperaturnog raspona. Kori\u0161tenje aktuatora izvan nazivnog temperaturnog raspona mo\u017ee dovesti do kvara ili smanjenog vijeka trajanja, \u0161to u kona\u010dnici uzrokuje kvar.<\/p><\/li><li class=\"\" data-start=\"6084\" data-end=\"6498\"><p class=\"\" data-start=\"6086\" data-end=\"6498\"><strong data-start=\"6086\" data-end=\"6101\">Okoli\u0161<\/strong>Pogoni s DCL prekida\u010dem imaju IP67 stupanj za\u0161tite za vremenske uvjete, pogodni su za unutarnju i vanjsku upotrebu. Nude odre\u0111enu za\u0161titu od ki\u0161e, prskanja vode i UV zra\u010denja (sun\u010deve svjetlosti), \u0161to obi\u010dno produ\u017euje vijek trajanja proizvoda. Me\u0111utim, vrlo korozivna okru\u017eenja mogu uzrokovati prerano kvarenje elektroni\u010dkih komponenti. Ne koristite aktuatore serije koji nisu otporni na eksploziju u opasnim okru\u017eenjima.<\/p><\/li><li class=\"\" data-start=\"6500\" data-end=\"6708\"><p class=\"\" data-start=\"6502\" data-end=\"6708\"><strong data-start=\"6502\" data-end=\"6516\">Radni ciklus<\/strong>Pogon s DCL prekida\u010dem ima radni ciklus od 70% (42 sekunde rada nakon \u010dega slijedi 18 sekundi mirovanja). Prekora\u010denje ovog radnog ciklusa mo\u017ee uzrokovati ulazak motora u na\u010din rada toplinske za\u0161tite.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-823dd6a elementor-widget elementor-widget-heading\" data-id=\"823dd6a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Provjerite o\u017ei\u010denje aktuatora<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-32ec269 elementor-widget elementor-widget-text-editor\" data-id=\"32ec269\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"41\" data-end=\"104\">Kako biste osigurali ispravan rad aktuatora, slijedite ove korake:<\/p><ol data-start=\"106\" data-end=\"1403\"><li class=\"\" data-start=\"106\" data-end=\"331\"><p class=\"\" data-start=\"109\" data-end=\"156\"><strong data-start=\"109\" data-end=\"156\">Provjerite o\u017ei\u010denje prema dijagramu:<\/strong><\/p><ul data-start=\"160\" data-end=\"331\"><li class=\"\" data-start=\"160\" data-end=\"237\"><p class=\"\" data-start=\"162\" data-end=\"237\">Dvaput provjerite o\u017ei\u010denje kako biste bili sigurni da odgovara shemi o\u017ei\u010denja aktuatora.<\/p><\/li><li class=\"\" data-start=\"241\" data-end=\"327\"><p class=\"\" data-start=\"243\" data-end=\"327\">Provjerite jesu li svi spojevi sigurni i da nijedna \u017eica nije labava ili odspojena.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"332\" data-end=\"558\"><p class=\"\" data-start=\"335\" data-end=\"366\"><strong data-start=\"335\" data-end=\"366\">Provjerite ispravan polaritet:<\/strong><\/p><ul data-start=\"370\" data-end=\"558\"><li class=\"\" data-start=\"370\" data-end=\"483\"><p class=\"\" data-start=\"372\" data-end=\"483\">Provjerite jesu li pozitivni i negativni terminali napajanja spojeni na ispravne terminale aktuatora.<\/p><\/li><li class=\"\" data-start=\"487\" data-end=\"558\"><p class=\"\" data-start=\"489\" data-end=\"558\">Nepravilan polaritet mo\u017ee dovesti do kvara ili o\u0161te\u0107enja aktuatora.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"560\" data-end=\"787\"><p class=\"\" data-start=\"563\" data-end=\"601\"><strong data-start=\"563\" data-end=\"601\">Pregledajte o\u017ei\u010denje upravlja\u010dkog signala:<\/strong><\/p><ul data-start=\"605\" data-end=\"787\"><li class=\"\" data-start=\"605\" data-end=\"687\"><p class=\"\" data-start=\"607\" data-end=\"687\">Provjerite o\u017ei\u010denje za upravlja\u010dke signale (npr. ulazni signal, signal povratne veze).<\/p><\/li><li class=\"\" data-start=\"691\" data-end=\"787\"><p class=\"\" data-start=\"693\" data-end=\"787\">Provjerite jesu li signalne \u017eice ispravno spojene i da nemaju kratkih spojeva ili prekida.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"789\" data-end=\"1011\"><p class=\"\" data-start=\"792\" data-end=\"816\"><strong data-start=\"792\" data-end=\"816\">Provjerite uzemljenje:<\/strong><\/p><ul data-start=\"820\" data-end=\"1011\"><li class=\"\" data-start=\"820\" data-end=\"929\"><p class=\"\" data-start=\"822\" data-end=\"929\">Osigurajte pravilno uzemljenje aktuatora kako biste izbjegli elektri\u010dne smetnje ili potencijalne kratke spojeve.<\/p><\/li><li class=\"\" data-start=\"933\" data-end=\"1011\"><p class=\"\" data-start=\"935\" data-end=\"1011\">Neispravan spoj uzemljenja mo\u017ee uzrokovati nepravilno pona\u0161anje ili kvar u radu.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"1013\" data-end=\"1212\"><p class=\"\" data-start=\"1016\" data-end=\"1063\"><strong data-start=\"1016\" data-end=\"1063\">Potvrdite o\u017ei\u010denje za vanjske komponente:<\/strong><\/p><ul data-start=\"1067\" data-end=\"1212\"><li class=\"\" data-start=\"1067\" data-end=\"1208\"><p class=\"\" data-start=\"1069\" data-end=\"1208\">Ako su spojeni vanjski ure\u0111aji poput grani\u010dnih sklopki, senzora ili dodatnih upravlja\u010dkih modula, provjerite je li o\u017ei\u010denje sigurno i ispravno.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"1213\" data-end=\"1403\"><p class=\"\" data-start=\"1216\" data-end=\"1245\"><strong data-start=\"1216\" data-end=\"1245\">Testirajte upravlja\u010dki krug:<\/strong><\/p><ul data-start=\"1249\" data-end=\"1403\"><li class=\"\" data-start=\"1249\" data-end=\"1351\"><p class=\"\" data-start=\"1251\" data-end=\"1351\">Za provjeru upravlja\u010dkog kruga, uklju\u010duju\u0107i ulazni napon na upravlja\u010dkim terminalima, koristite multimetar.<\/p><\/li><li class=\"\" data-start=\"1355\" data-end=\"1403\"><p class=\"\" data-start=\"1357\" data-end=\"1403\">Potvrdite da je prisutan o\u010dekivani raspon napona.<\/p><\/li><\/ul><\/li><\/ol><p class=\"\" data-start=\"1405\" data-end=\"1634\">Nakon \u0161to potvrdite da je o\u017ei\u010denje ispravno, nastavite s testiranjem aktuatora kako biste osigurali da ispravno radi. Ako se problemi nastave i nakon provjere o\u017ei\u010denja, mo\u017eda \u0107e biti potreban daljnji pregled unutarnjih komponenti aktuatora.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-422047d elementor-widget elementor-widget-template\" data-id=\"422047d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"template.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-template\">\n\t\t\t\t\t<div data-elementor-type=\"section\" data-elementor-id=\"10970\" class=\"elementor elementor-10970\" data-elementor-post-type=\"elementor_library\">\n\t\t\t<div class=\"elementor-element elementor-element-19a6173 e-flex e-con-boxed e-con e-parent\" data-id=\"19a6173\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-984e463 e-con-full e-flex e-con e-child\" data-id=\"984e463\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d08c8ca elementor-widget elementor-widget-heading\" data-id=\"d08c8ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">E - Modulacija pomo\u0107u upravlja\u010dke jedinice<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e3dcbb5 elementor-widget elementor-widget-image\" data-id=\"e3dcbb5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"400\" height=\"330\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-e.webp\" class=\"attachment-full size-full wp-image-4857\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668E\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4396a8e elementor-widget elementor-widget-text-editor\" data-id=\"4396a8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Ulaznica: 4~20 mA \/ 0~10 V<\/li><li>Izlaz: 4~20 mA \/ 0~10 V<\/li><\/ul><p>\u00a0<\/p><p><strong>Detalji povezivanja:<\/strong><\/p><ol><li>Spajanje AC85-220V napajanja na L i neutralni na N.<\/li><li>Spajanje izvora ulaznog signala 4-20mA\/2-10V iz upravlja\u010dkog sustava na ulaz-\/+.<\/li><li>Spajanje izlaza -\/+ na sustav za slanje polo\u017eaja ventila u stvarnom vremenu.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ff65758 e-con-full e-flex e-con e-parent\" data-id=\"ff65758\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-d5dc048 e-con-full e-flex e-con e-child\" data-id=\"d5dc048\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-527200f elementor-widget elementor-widget-text-editor\" data-id=\"527200f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Napomena:<\/p><ul><li>Kolo unutar prekri\u017eenih linija je unutarnje kolo aktuatora. Dok je kolo izvan njih demonstracija elektri\u010dne veze za kori\u0161tenje aktuatora.<\/li><li>Ako imate druge specifi\u010dne zahtjeve u vezi s povezivanjem kruga, slobodno kontaktirajte na\u0161u tehni\u010dku podr\u0161ku.\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-09f9fde elementor-widget elementor-widget-text-editor\" data-id=\"09f9fde\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Prilikom rje\u0161avanja problema na licu mjesta, mo\u017eete odmah kontaktirati na\u0161 tim za tehni\u010dku podr\u0161ku kako bismo zajedno rije\u0161ili problem i odredili rje\u0161enje.<\/p><p>Kontakt broj: 13026331611 (g. Chen)<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Ovaj vodi\u010d odnosi se na DCL ultra male moduliraju\u0107e aktuatore, model kako slijedi: DCL-02E Uobi\u010dajeni kvarovi i metode rje\u0161avanja problema Kvar Mogu\u0107i uzrok Metoda rje\u0161avanja problema Pogon se ne otvara ili zatvara pri pokretanju 1. Neispravno o\u017ei\u010denje Provjerite o\u017ei\u010denje prema dijagramu o\u017ei\u010denja aktuatora kako biste potvrdili da je ispravno. 2. Neispravno napajanje [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[103],"tags":[53],"class_list":["post-6034","post","type-post","status-publish","format-standard","hentry","category-mr-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/hr\/wp-json\/wp\/v2\/posts\/6034","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/hr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/hr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/hr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/hr\/wp-json\/wp\/v2\/comments?post=6034"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/hr\/wp-json\/wp\/v2\/posts\/6034\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/hr\/wp-json\/wp\/v2\/media?parent=6034"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/hr\/wp-json\/wp\/v2\/categories?post=6034"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/hr\/wp-json\/wp\/v2\/tags?post=6034"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}