{"id":5308,"date":"2023-05-25T14:38:18","date_gmt":"2023-05-25T06:38:18","guid":{"rendered":"http:\/\/www.dcl-controls.com\/?p=5308"},"modified":"2025-03-23T06:24:19","modified_gmt":"2025-03-23T06:24:19","slug":"set-up-dcl-actuator","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/fr_be\/soutien\/comment-actionner-lactionneur\/configurer-lactionneur-dcl","title":{"rendered":"Comment installer une \u00e9lectrovanne modulante ?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5308\" class=\"elementor elementor-5308\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c3b7996 e-con-full e-flex e-con e-child\" data-id=\"c3b7996\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-11d7691 elementor-widget elementor-widget-heading\" data-id=\"11d7691\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">1. Installation de l&#039;actionneur sur la vanne<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9720240 elementor-widget elementor-widget-text-editor\" data-id=\"9720240\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Suivez les instructions d&#039;installation dans <strong data-start=\"145\" data-end=\"193\">\u00ab\u00a0Comment installer l\u2019actionneur sur la vanne\u00a0\u00bb<\/strong> Installez correctement l&#039;actionneur sur la vanne. V\u00e9rifiez le bon fonctionnement en testant manuellement le mouvement de la vanne.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea3a72d elementor-widget elementor-widget-heading\" data-id=\"ea3a72d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2. R\u00e9glage des but\u00e9es m\u00e9caniques en position compl\u00e8tement ferm\u00e9e<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f43def1 elementor-widget elementor-widget-text-editor\" data-id=\"f43def1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li class=\"\" data-start=\"380\" data-end=\"532\"><p class=\"\" data-start=\"382\" data-end=\"532\">Utilisez le volant pour d\u00e9placer la vanne vers la position suivante : <strong data-start=\"425\" data-end=\"450\">position compl\u00e8tement ferm\u00e9e<\/strong>. Veillez \u00e0 ce que la but\u00e9e m\u00e9canique ne touche pas la vis de r\u00e9glage ni le bo\u00eetier.<\/p><\/li><li class=\"\" data-start=\"533\" data-end=\"706\"><p class=\"\" data-start=\"535\" data-end=\"706\">Desserrez le <strong data-start=\"546\" data-end=\"575\">vis de blocage de la plaque d&#039;\u00e9chelle<\/strong>, ajustez la plaque gradu\u00e9e de sorte que l&#039;aiguille s&#039;aligne avec le <strong data-start=\"636\" data-end=\"653\">marque du 0 degr\u00e9<\/strong> (Position FERM\u00c9E), puis serrez la vis de verrouillage.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c4faa9b elementor-widget elementor-widget-heading\" data-id=\"c4faa9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">3. R\u00e9glage des but\u00e9es m\u00e9caniques en position compl\u00e8tement ouverte<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69328ab elementor-widget elementor-widget-text-editor\" data-id=\"69328ab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul data-start=\"778\" data-end=\"1048\"><li class=\"\" data-start=\"778\" data-end=\"928\"><p class=\"\" data-start=\"780\" data-end=\"928\">Utilisez le volant pour d\u00e9placer la vanne vers la position suivante : <strong data-start=\"823\" data-end=\"846\">poste enti\u00e8rement ouvert<\/strong>. Veillez \u00e0 ce que la but\u00e9e m\u00e9canique ne touche pas la vis de r\u00e9glage ni le bo\u00eetier.<\/p><\/li><li class=\"\" data-start=\"929\" data-end=\"1048\"><p class=\"\" data-start=\"931\" data-end=\"1048\">Si la course de la soupape est de 90\u00b0, l&#039;aiguille doit \u00eatre align\u00e9e avec le <strong data-start=\"995\" data-end=\"1012\">marque du 0 degr\u00e9<\/strong> (Position OUVERTE) sur la plaque gradu\u00e9e.<\/p><\/li><\/ul><p class=\"\" data-start=\"1050\" data-end=\"1072\"><strong data-start=\"1050\" data-end=\"1070\">Remarques importantes\u00a0:<\/strong><\/p><ul data-start=\"1073\" data-end=\"1878\"><li class=\"\" data-start=\"1073\" data-end=\"1230\"><p class=\"\" data-start=\"1075\" data-end=\"1230\">Sauf indication contraire, lors de la mise au point en usine, l&#039;angle de course de l&#039;actionneur entre les positions compl\u00e8tement ferm\u00e9e et compl\u00e8tement ouverte est g\u00e9n\u00e9ralement <strong data-start=\"1220\" data-end=\"1227\">90\u00b0<\/strong>.<\/p><\/li><li class=\"\" data-start=\"1231\" data-end=\"1447\"><p class=\"\" data-start=\"1233\" data-end=\"1447\">Apr\u00e8s appariement des vannes, si les positions compl\u00e8tement ferm\u00e9e et compl\u00e8tement ouverte de l&#039;actionneur ne correspondent pas \u00e0 celles de la vanne, des ajustements doivent \u00eatre effectu\u00e9s. Assurez-vous que les but\u00e9es m\u00e9caniques sont r\u00e9gl\u00e9es conform\u00e9ment au sch\u00e9ma ci-dessous.<\/p><\/li><li class=\"\" data-start=\"1448\" data-end=\"1665\"><p class=\"\" data-start=\"1450\" data-end=\"1665\">Tous les actionneurs modulants (type E) prennent d\u00e9j\u00e0 en compte les variations potentielles de la plage de fonctionnement du potentiom\u00e8tre lors de l&#039;adaptation des vannes. Par cons\u00e9quent, aucun r\u00e9glage du potentiom\u00e8tre ni des engrenages n&#039;est g\u00e9n\u00e9ralement n\u00e9cessaire.<\/p><\/li><li class=\"\" data-start=\"1666\" data-end=\"1878\"><p class=\"\" data-start=\"1668\" data-end=\"1878\">Les bornes de c\u00e2blage doivent \u00eatre correctement connect\u00e9es comme indiqu\u00e9 sur le sch\u00e9ma afin d&#039;\u00e9viter d&#039;endommager le servocontr\u00f4leur. Ne connectez pas le <strong data-start=\"1798\" data-end=\"1809\">&quot;pouvoir&quot;<\/strong> terminal vers le <strong data-start=\"1826\" data-end=\"1844\">\u00ab signal d\u2019entr\u00e9e \u00bb<\/strong> ou <strong data-start=\"1848\" data-end=\"1867\">\u00ab signal de sortie \u00bb<\/strong> terminaux.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-752675b elementor-widget elementor-widget-image\" data-id=\"752675b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"271\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/position-limiter-setting-cn.webp\" class=\"attachment-full size-full wp-image-5316\" alt=\"\u534e\u6613\u79d1\u6280 \u673a\u68b0\u7535\u6c14\u9650\u4f4d\u5173\u7cfb \u793a\u610f\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ae7eee elementor-widget elementor-widget-heading\" data-id=\"6ae7eee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">4. Explication du panneau de commande du servomoteur<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b3a45f5 e-con-full e-flex e-con e-child\" data-id=\"b3a45f5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-b6af4cd e-con-full e-flex e-con e-child\" data-id=\"b6af4cd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b5e8e96 elementor-widget elementor-widget-image\" data-id=\"b5e8e96\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"600\" height=\"599\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/sf-lc-servo-control-pack-cn.webp\" class=\"attachment-full size-full wp-image-5318\" alt=\"\u534e\u6613\u79d1\u6280\u7535\u52a8\u6267\u884c\u5668 LC\u63a7\u5236\u6a21\u5757 \u63a5\u53e3\u793a\u610f\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4f5c1c9 e-con-full e-flex e-con e-child\" data-id=\"4f5c1c9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-144627d elementor-widget elementor-widget-image\" data-id=\"144627d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"600\" height=\"606\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/sf-zc-servo-control-pack-cn.webp\" class=\"attachment-full size-full wp-image-5320\" alt=\"\u534e\u6613\u79d1\u6280\u7535\u52a8\u9600 \u63a7\u5236\u6a21\u5757 \u63a5\u53e3\u793a\u610f\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1bbbb68 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"1bbbb68\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"1933\" data-end=\"1951\"><strong data-start=\"1933\" data-end=\"1951\">Fonctions cl\u00e9s :<\/strong><\/p><ul data-start=\"1952\" data-end=\"2214\"><li class=\"\" data-start=\"1952\" data-end=\"2036\"><p class=\"\" data-start=\"1954\" data-end=\"2036\"><strong data-start=\"1954\" data-end=\"1963\">Ouvrir:<\/strong> Dans <strong data-start=\"1967\" data-end=\"1982\">\u00ab D\u00e9finir l\u2019\u00e9tat \u00bb<\/strong>Appuyez sur cette touche pour ouvrir la vanne. Rel\u00e2chez-la pour arr\u00eater.<\/p><\/li><li class=\"\" data-start=\"2037\" data-end=\"2122\"><p class=\"\" data-start=\"2039\" data-end=\"2122\"><strong data-start=\"2039\" data-end=\"2048\">Fermer:<\/strong> Dans <strong data-start=\"2052\" data-end=\"2067\">\u00ab D\u00e9finir l\u2019\u00e9tat \u00bb<\/strong>Appuyez sur cette touche pour fermer la vanne. Rel\u00e2chez-la pour arr\u00eater.<\/p><\/li><li class=\"\" data-start=\"2123\" data-end=\"2214\"><p class=\"\" data-start=\"2125\" data-end=\"2214\"><strong data-start=\"2125\" data-end=\"2133\">Ensemble:<\/strong> Dans <strong data-start=\"2137\" data-end=\"2152\">\u00ab D\u00e9finir l\u2019\u00e9tat \u00bb<\/strong>, utiliser avec <strong data-start=\"2163\" data-end=\"2171\">Ouvrir<\/strong> ou <strong data-start=\"2175\" data-end=\"2183\">Fermer<\/strong> pour r\u00e9aliser des fonctions sp\u00e9cifiques.<\/p><\/li><\/ul><p class=\"\" data-start=\"2216\" data-end=\"2239\"><strong data-start=\"2216\" data-end=\"2239\">Commutateurs de s\u00e9lection\u00a0:<\/strong><\/p><ul data-start=\"2240\" data-end=\"2661\"><li class=\"\" data-start=\"2240\" data-end=\"2485\"><p class=\"\" data-start=\"2242\" data-end=\"2404\"><strong data-start=\"2242\" data-end=\"2268\">SA (S\u00e9lection du signal) :<\/strong> S\u00e9lectionnez le type de signal d&#039;entr\u00e9e (direct ou inverse) et d\u00e9finissez l&#039;\u00e9tat. Assurez-vous que l&#039;appareil est sous tension pour que la modification soit prise en compte.<\/p><ul data-start=\"2407\" data-end=\"2485\"><li class=\"\" data-start=\"2407\" data-end=\"2432\"><p class=\"\" data-start=\"2409\" data-end=\"2432\"><strong data-start=\"2409\" data-end=\"2414\">1<\/strong> \u2013 Action directe<\/p><\/li><li class=\"\" data-start=\"2435\" data-end=\"2456\"><p class=\"\" data-start=\"2437\" data-end=\"2456\"><strong data-start=\"2437\" data-end=\"2442\">2<\/strong> \u2013 D\u00e9finir l&#039;\u00e9tat<\/p><\/li><li class=\"\" data-start=\"2459\" data-end=\"2485\"><p class=\"\" data-start=\"2461\" data-end=\"2485\"><strong data-start=\"2461\" data-end=\"2466\">3<\/strong> \u2013 Action inverse<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"2486\" data-end=\"2661\"><p class=\"\" data-start=\"2488\" data-end=\"2560\"><strong data-start=\"2488\" data-end=\"2521\">SB (Gestion des d\u00e9faillances de signal) :<\/strong> S\u00e9lectionnez la m\u00e9thode de gestion des d\u00e9faillances de signal.<\/p><ul data-start=\"2563\" data-end=\"2661\"><li class=\"\" data-start=\"2563\" data-end=\"2591\"><p class=\"\" data-start=\"2565\" data-end=\"2591\"><strong data-start=\"2565\" data-end=\"2570\">1<\/strong> \u2013 Vanne compl\u00e8tement ouverte<\/p><\/li><li class=\"\" data-start=\"2594\" data-end=\"2630\"><p class=\"\" data-start=\"2596\" data-end=\"2630\"><strong data-start=\"2596\" data-end=\"2601\">2<\/strong> \u2013 La vanne maintient sa position<\/p><\/li><li class=\"\" data-start=\"2633\" data-end=\"2661\"><p class=\"\" data-start=\"2635\" data-end=\"2661\"><strong data-start=\"2635\" data-end=\"2640\">3<\/strong> \u2013 Vanne compl\u00e8tement ferm\u00e9e<\/p><\/li><\/ul><\/li><\/ul><p class=\"\" data-start=\"2663\" data-end=\"2700\"><strong data-start=\"2663\" data-end=\"2698\">Potentiom\u00e8tre de r\u00e9glage de la zone morte\u00a0:<\/strong><\/p><ul data-start=\"2701\" data-end=\"2838\"><li class=\"\" data-start=\"2701\" data-end=\"2838\"><p class=\"\" data-start=\"2703\" data-end=\"2838\">Ajustez la valeur de la zone morte \u00e0 partir de <strong data-start=\"2734\" data-end=\"2750\">0,5% \u00e0 5,0%<\/strong> (param\u00e8tres d&#039;usine par d\u00e9faut) <strong data-start=\"2775\" data-end=\"2783\">1.5%<\/strong>Chaque r\u00e9glage augmente la zone morte de <strong data-start=\"2829\" data-end=\"2837\">0.5%<\/strong>.<\/p><\/li><\/ul><p class=\"\" data-start=\"2840\" data-end=\"2857\"><strong data-start=\"2840\" data-end=\"2855\">Indicateurs :<\/strong><\/p><ul data-start=\"2858\" data-end=\"3262\"><li class=\"\" data-start=\"2858\" data-end=\"2937\"><p class=\"\" data-start=\"2860\" data-end=\"2937\"><strong data-start=\"2860\" data-end=\"2875\">L1 (Vert) :<\/strong> Voyant de mise sous tension (s&#039;allume lorsque le contr\u00f4leur est aliment\u00e9).<\/p><\/li><li class=\"\" data-start=\"2938\" data-end=\"3024\"><p class=\"\" data-start=\"2940\" data-end=\"3024\"><strong data-start=\"2940\" data-end=\"2953\">L2 (Rouge) :<\/strong> Indicateur de panne du signal d&#039;entr\u00e9e (s&#039;allume en cas de panne du signal d&#039;entr\u00e9e).<\/p><\/li><li class=\"\" data-start=\"3025\" data-end=\"3169\"><p class=\"\" data-start=\"3027\" data-end=\"3169\"><strong data-start=\"3027\" data-end=\"3040\">L3 (Rouge) :<\/strong> Indicateur de d\u00e9faut du circuit de d\u00e9tection de position (s&#039;allume en cas de probl\u00e8me avec le c\u00e2blage ou le composant du potentiom\u00e8tre de position).<\/p><\/li><li class=\"\" data-start=\"3170\" data-end=\"3262\"><p class=\"\" data-start=\"3172\" data-end=\"3262\"><strong data-start=\"3172\" data-end=\"3185\">L4 (Rouge) :<\/strong> Indicateur de blocage m\u00e9canique (s&#039;allume en cas de blocage du m\u00e9canisme).<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-355ac67 elementor-widget elementor-widget-heading\" data-id=\"355ac67\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">5. Param\u00e8tres<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fef02da elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"fef02da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"3291\" data-end=\"3316\"><strong data-start=\"3291\" data-end=\"3314\">Entr\u00e9e dans l&#039;\u00e9tat d\u00e9fini\u00a0:<\/strong><\/p><ul data-start=\"3317\" data-end=\"3539\"><li class=\"\" data-start=\"3317\" data-end=\"3539\"><p class=\"\" data-start=\"3319\" data-end=\"3539\">R\u00e9glez le <strong data-start=\"3327\" data-end=\"3340\">Interrupteur SA<\/strong> position <strong data-start=\"3353\" data-end=\"3358\">2<\/strong>, entrant dans <strong data-start=\"3373\" data-end=\"3386\">D\u00e9finir l&#039;\u00e9tat<\/strong>, o\u00f9 des fonctions telles que l&#039;\u00e9talonnage de la course, la gestion des pannes de signal, le r\u00e9glage de la zone morte, le fonctionnement manuel et l&#039;\u00e9talonnage du courant de sortie peuvent \u00eatre configur\u00e9es.<\/p><\/li><\/ul><p class=\"\" data-start=\"3541\" data-end=\"3564\"><strong data-start=\"3541\" data-end=\"3564\">Calibrage de la course :<\/strong><\/p><ul data-start=\"3565\" data-end=\"4167\"><li class=\"\" data-start=\"3565\" data-end=\"3870\"><p class=\"\" data-start=\"3567\" data-end=\"3598\"><strong data-start=\"3567\" data-end=\"3596\">\u00c9talonnage enti\u00e8rement ferm\u00e9\u00a0:<\/strong><\/p><ul data-start=\"3601\" data-end=\"3870\"><li class=\"\" data-start=\"3601\" data-end=\"3867\"><p class=\"\" data-start=\"3603\" data-end=\"3867\">Utiliser <strong data-start=\"3607\" data-end=\"3615\">Ouvrir<\/strong> ou <strong data-start=\"3619\" data-end=\"3627\">Fermer<\/strong> Pour fermer compl\u00e8tement la vanne, appuyez sur le bouton et maintenez-le enfonc\u00e9. <strong data-start=\"3695\" data-end=\"3702\">Ensemble<\/strong> bouton, puis appuyez sur <strong data-start=\"3722\" data-end=\"3730\">Fermer<\/strong>Maintenez les deux boutons enfonc\u00e9s pendant environ <strong data-start=\"3768\" data-end=\"3781\">4 secondes<\/strong> jusqu&#039;\u00e0 <strong data-start=\"3788\" data-end=\"3794\">L2<\/strong> Le voyant s&#039;allume. Rel\u00e2chez les deux boutons pour terminer l&#039;\u00e9talonnage complet en position ferm\u00e9e.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"3871\" data-end=\"4167\"><p class=\"\" data-start=\"3873\" data-end=\"3902\"><strong data-start=\"3873\" data-end=\"3900\">\u00c9talonnage enti\u00e8rement ouvert\u00a0:<\/strong><\/p><ul data-start=\"3905\" data-end=\"4167\"><li class=\"\" data-start=\"3905\" data-end=\"4167\"><p class=\"\" data-start=\"3907\" data-end=\"4167\">Utiliser <strong data-start=\"3911\" data-end=\"3919\">Ouvrir<\/strong> ou <strong data-start=\"3923\" data-end=\"3931\">Fermer<\/strong> pour ouvrir compl\u00e8tement la vanne. Appuyez et maintenez enfonc\u00e9 le <strong data-start=\"3997\" data-end=\"4004\">Ensemble<\/strong> bouton, puis appuyez sur <strong data-start=\"4024\" data-end=\"4032\">Ouvrir<\/strong>Maintenez les deux boutons enfonc\u00e9s pendant environ <strong data-start=\"4070\" data-end=\"4083\">4 secondes<\/strong> jusqu&#039;\u00e0 <strong data-start=\"4090\" data-end=\"4096\">L2<\/strong> Le voyant s&#039;allume. Rel\u00e2chez les deux boutons pour terminer l&#039;\u00e9talonnage complet.<\/p><\/li><\/ul><\/li><\/ul><p class=\"\" data-start=\"4169\" data-end=\"4205\"><strong data-start=\"4169\" data-end=\"4203\">Gestion des d\u00e9faillances des signaux d&#039;entr\u00e9e\u00a0:<\/strong><\/p><ul data-start=\"4206\" data-end=\"4511\"><li class=\"\" data-start=\"4206\" data-end=\"4391\"><p class=\"\" data-start=\"4208\" data-end=\"4292\">Utilisez le <strong data-start=\"4216\" data-end=\"4229\">Interrupteur SB<\/strong> pour s\u00e9lectionner comment le syst\u00e8me doit g\u00e9rer les d\u00e9faillances du signal d&#039;entr\u00e9e\u00a0:<\/p><ul data-start=\"4295\" data-end=\"4391\"><li class=\"\" data-start=\"4295\" data-end=\"4323\"><p class=\"\" data-start=\"4297\" data-end=\"4323\"><strong data-start=\"4297\" data-end=\"4302\">1<\/strong> \u2013 Vanne compl\u00e8tement ouverte<\/p><\/li><li class=\"\" data-start=\"4326\" data-end=\"4358\"><p class=\"\" data-start=\"4328\" data-end=\"4358\"><strong data-start=\"4328\" data-end=\"4333\">2<\/strong> \u2013 La vanne maintient sa position<\/p><\/li><li class=\"\" data-start=\"4361\" data-end=\"4391\"><p class=\"\" data-start=\"4363\" data-end=\"4391\"><strong data-start=\"4363\" data-end=\"4368\">3<\/strong> \u2013 Vanne compl\u00e8tement ferm\u00e9e<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"4392\" data-end=\"4511\"><p class=\"\" data-start=\"4394\" data-end=\"4511\">Remarque : Modifier le <strong data-start=\"4413\" data-end=\"4426\">Interrupteur SB<\/strong> est efficace m\u00eame en mode automatique (lorsque <strong data-start=\"4478\" data-end=\"4484\">SA<\/strong> est r\u00e9gl\u00e9 sur <strong data-start=\"4495\" data-end=\"4500\">1<\/strong> ou <strong data-start=\"4504\" data-end=\"4509\">3<\/strong>).<\/p><\/li><\/ul><p class=\"\" data-start=\"4513\" data-end=\"4542\"><strong data-start=\"4513\" data-end=\"4540\">R\u00e9glage de la valeur de la zone morte\u00a0:<\/strong><\/p><ul data-start=\"4543\" data-end=\"4737\"><li class=\"\" data-start=\"4543\" data-end=\"4737\"><p class=\"\" data-start=\"4545\" data-end=\"4737\">Faites pivoter le <strong data-start=\"4556\" data-end=\"4582\">potentiom\u00e8tre \u00e0 zone morte<\/strong> Tournez dans le sens horaire pour augmenter la zone morte et dans le sens antihoraire pour la diminuer. Chaque incr\u00e9ment modifie la zone morte de <strong data-start=\"4695\" data-end=\"4703\">0.5%<\/strong>La valeur par d\u00e9faut d&#039;usine est <strong data-start=\"4728\" data-end=\"4736\">1.5%<\/strong>.<\/p><\/li><\/ul><p class=\"\" data-start=\"4739\" data-end=\"4837\">Vous pouvez ouvrir ou fermer manuellement la vanne \u00e0 l&#039;aide de la <strong data-start=\"4790\" data-end=\"4798\">Ouvrir<\/strong> ou <strong data-start=\"4802\" data-end=\"4810\">Fermer<\/strong> cl\u00e9s dans le <strong data-start=\"4823\" data-end=\"4836\">D\u00e9finir l&#039;\u00e9tat<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80849e9 elementor-widget elementor-widget-heading\" data-id=\"80849e9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">6. Op\u00e9ration<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-422d8e7 elementor-widget elementor-widget-text-editor\" data-id=\"422d8e7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"4867\" data-end=\"4902\"><strong data-start=\"4867\" data-end=\"4900\">Passage en mode automatique\u00a0:<\/strong><\/p><ul data-start=\"4903\" data-end=\"5074\"><li class=\"\" data-start=\"4903\" data-end=\"5074\"><p class=\"\" data-start=\"4905\" data-end=\"5074\">R\u00e9glez le <strong data-start=\"4913\" data-end=\"4926\">Interrupteur SA<\/strong> \u00e0 <strong data-start=\"4930\" data-end=\"4935\">1<\/strong> ou <strong data-start=\"4939\" data-end=\"4944\">3<\/strong> entrer <strong data-start=\"4954\" data-end=\"4977\">Fonctionnement automatique<\/strong>Dans ce mode, la position et le signal de sortie de l&#039;actionneur suivent les variations du signal d&#039;entr\u00e9e.<\/p><\/li><\/ul><p class=\"\" data-start=\"5076\" data-end=\"5087\"><strong data-start=\"5076\" data-end=\"5085\">Note:<\/strong><\/p><ul data-start=\"5088\" data-end=\"5362\"><li class=\"\" data-start=\"5088\" data-end=\"5225\"><p class=\"\" data-start=\"5090\" data-end=\"5225\">Dans <strong data-start=\"5093\" data-end=\"5111\">Action inverse<\/strong>, un <strong data-start=\"5115\" data-end=\"5122\">4 mA<\/strong> L&#039;entr\u00e9e correspond \u00e0 un <strong data-start=\"5146\" data-end=\"5154\">100%<\/strong> ouverture de la vanne, tandis qu&#039;une <strong data-start=\"5178\" data-end=\"5186\">20 mA<\/strong> L&#039;entr\u00e9e correspond \u00e0 un <strong data-start=\"5210\" data-end=\"5216\">0%<\/strong> ouverture.<\/p><\/li><li class=\"\" data-start=\"5226\" data-end=\"5362\"><p class=\"\" data-start=\"5228\" data-end=\"5362\">Le servocontr\u00f4leur a un niveau de pr\u00e9cision de <strong data-start=\"5274\" data-end=\"5285\">Classe 1<\/strong>, avec une erreur fondamentale d&#039;au plus <strong data-start=\"5322\" data-end=\"5329\">\u00b11%<\/strong> et une hyst\u00e9r\u00e9sis inf\u00e9rieure \u00e0 <strong data-start=\"5355\" data-end=\"5361\">1%<\/strong>.<\/p><\/li><\/ul><p class=\"\" data-start=\"5364\" data-end=\"5402\"><strong data-start=\"5364\" data-end=\"5402\">Courant de sortie en fonction de la position de la vanne\u00a0:<\/strong><\/p><div class=\"overflow-x-auto contain-inline-size\"><table data-start=\"5404\" data-end=\"5655\"><thead data-start=\"5404\" data-end=\"5465\"><tr data-start=\"5404\" data-end=\"5465\"><th data-start=\"5404\" data-end=\"5419\">Signal d&#039;entr\u00e9e<\/th><th data-start=\"5419\" data-end=\"5428\">4 mA<\/th><th data-start=\"5428\" data-end=\"5437\">8 mA<\/th><th data-start=\"5437\" data-end=\"5446\">12 mA<\/th><th data-start=\"5446\" data-end=\"5455\">16 mA<\/th><th data-start=\"5455\" data-end=\"5465\">20 mA<\/th><\/tr><\/thead><tbody data-start=\"5528\" data-end=\"5655\"><tr data-start=\"5528\" data-end=\"5591\"><td>Position de la vanne<\/td><td>0%<\/td><td>25%<\/td><td>50%<\/td><td>75%<\/td><td>100%<\/td><\/tr><tr data-start=\"5592\" data-end=\"5655\"><td>Courant de sortie<\/td><td>4 mA<\/td><td>8 mA<\/td><td>12 mA<\/td><td>16 mA<\/td><td>20 mA<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d54eb82 elementor-widget elementor-widget-heading\" data-id=\"d54eb82\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">7. \u00c9talonnage du courant de sortie<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-669115e elementor-widget elementor-widget-text-editor\" data-id=\"669115e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5702\" data-end=\"5963\"><strong data-start=\"5702\" data-end=\"5726\">Calibrage en usine\u00a0:<\/strong><br data-start=\"5726\" data-end=\"5729\" \/>Le servocontr\u00f4leur est calibr\u00e9 en usine, aucun r\u00e9glage par l&#039;utilisateur n&#039;est donc g\u00e9n\u00e9ralement n\u00e9cessaire. Toutefois, si le courant de sortie en position compl\u00e8tement ferm\u00e9e (4 mA) ou compl\u00e8tement ouverte (20 mA) s&#039;\u00e9carte de plus de [valeur manquante], [valeur manquante]. <strong data-start=\"5926\" data-end=\"5932\">1%<\/strong>, vous devrez peut-\u00eatre le calibrer.<\/p><p class=\"\" data-start=\"5965\" data-end=\"5987\"><strong data-start=\"5965\" data-end=\"5987\">\u00c9tapes d&#039;\u00e9talonnage\u00a0:<\/strong><\/p><ol data-start=\"5988\" data-end=\"6547\"><li class=\"\" data-start=\"5988\" data-end=\"6035\"><p class=\"\" data-start=\"5991\" data-end=\"6035\">Connectez un <strong data-start=\"6001\" data-end=\"6020\">Amp\u00e8rem\u00e8tre CC 20 mA<\/strong> \u00e0 la sortie.<\/p><\/li><li class=\"\" data-start=\"6036\" data-end=\"6095\"><p class=\"\" data-start=\"6039\" data-end=\"6095\">R\u00e9glez le <strong data-start=\"6047\" data-end=\"6060\">Interrupteur SA<\/strong> \u00e0 <strong data-start=\"6064\" data-end=\"6069\">2<\/strong> entrer <strong data-start=\"6079\" data-end=\"6092\">D\u00e9finir l&#039;\u00e9tat<\/strong>.<\/p><\/li><li class=\"\" data-start=\"6096\" data-end=\"6196\"><p class=\"\" data-start=\"6099\" data-end=\"6196\">Appuyez et maintenez enfonc\u00e9 le <strong data-start=\"6118\" data-end=\"6125\">Ensemble<\/strong> bouton, puis appuyez simultan\u00e9ment sur le <strong data-start=\"6164\" data-end=\"6172\">Ouvrir<\/strong> et <strong data-start=\"6177\" data-end=\"6185\">Fermer<\/strong> boutons.<\/p><\/li><li class=\"\" data-start=\"6197\" data-end=\"6358\"><p class=\"\" data-start=\"6200\" data-end=\"6358\">Quand <strong data-start=\"6205\" data-end=\"6211\">L2<\/strong> Le voyant s&#039;allume, rel\u00e2chez tous les boutons et le syst\u00e8me entrera en marche. <strong data-start=\"6270\" data-end=\"6289\">Calibrage 4 mA<\/strong>Ajustez le courant \u00e0 <strong data-start=\"6313\" data-end=\"6320\">4 mA<\/strong> en utilisant le <strong data-start=\"6331\" data-end=\"6339\">Ouvrir<\/strong> et <strong data-start=\"6344\" data-end=\"6352\">Fermer<\/strong> cl\u00e9s.<\/p><\/li><li class=\"\" data-start=\"6359\" data-end=\"6547\"><p class=\"\" data-start=\"6362\" data-end=\"6547\">Apr\u00e8s avoir termin\u00e9 le <strong data-start=\"6383\" data-end=\"6402\">Calibrage 4 mA<\/strong>, appuyez et maintenez <strong data-start=\"6419\" data-end=\"6426\">Ensemble<\/strong> encore une fois et attendez <strong data-start=\"6446\" data-end=\"6452\">L2<\/strong> allumer. Rel\u00e2chez ensuite pour entrer. <strong data-start=\"6491\" data-end=\"6511\">Calibrage \u00e0 20 mA<\/strong> et ajuster le courant \u00e0 <strong data-start=\"6538\" data-end=\"6546\">20 mA<\/strong>.<\/p><\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64cb79a elementor-widget elementor-widget-heading\" data-id=\"64cb79a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">8. Diagnostic et d\u00e9pannage des pannes<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cf7d399 elementor-widget elementor-widget-text-editor\" data-id=\"cf7d399\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"flex max-w-full flex-col flex-grow\"><div class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 whitespace-normal break-words text-start [.text-message+&amp;]:mt-5\" dir=\"auto\" data-message-author-role=\"assistant\" data-message-id=\"1cd8ba4b-b609-46a1-82a1-72b8dd7af669\" data-message-model-slug=\"gpt-4o-mini\"><div class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\"><div class=\"markdown prose w-full break-words dark:prose-invert light\"><p class=\"\" data-start=\"6603\" data-end=\"6630\"><strong data-start=\"6603\" data-end=\"6630\">Voyants indicateurs de d\u00e9faut\u00a0:<\/strong><\/p><ul data-start=\"6631\" data-end=\"7071\"><li class=\"\" data-start=\"6631\" data-end=\"6844\"><p class=\"\" data-start=\"6633\" data-end=\"6709\"><strong data-start=\"6633\" data-end=\"6650\">L2 s&#039;allume :<\/strong><br data-start=\"6650\" data-end=\"6653\" \/>Panne du signal d&#039;entr\u00e9e \u2014 v\u00e9rifiez la tension du signal d&#039;entr\u00e9e.<\/p><ul data-start=\"6712\" data-end=\"6844\"><li class=\"\" data-start=\"6712\" data-end=\"6841\"><p class=\"\" data-start=\"6714\" data-end=\"6841\">Si la tension est anormale (en dehors de la plage 0,88-4,4 V), v\u00e9rifiez les circuits ouverts, les courts-circuits ou les sources de signal incorrectes.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"6845\" data-end=\"6978\"><p class=\"\" data-start=\"6847\" data-end=\"6978\"><strong data-start=\"6847\" data-end=\"6864\">L3 s&#039;allume :<\/strong><br data-start=\"6864\" data-end=\"6867\" \/>D\u00e9faut de d\u00e9tection de position\u00a0\u2014 v\u00e9rifiez le potentiom\u00e8tre pour d\u00e9tecter tout probl\u00e8me tel qu\u2019un circuit ouvert, un court-circuit ou un dommage.<\/p><\/li><li class=\"\" data-start=\"6982\" data-end=\"7071\"><p class=\"\" data-start=\"6984\" data-end=\"7071\"><strong data-start=\"6984\" data-end=\"7001\">L4 s&#039;allume :<\/strong><br data-start=\"7001\" data-end=\"7004\" \/>Blocage m\u00e9canique\u00a0\u2014 v\u00e9rifiez les connexions du moteur et de l\u2019actionneur pour d\u00e9tecter tout blocage.<\/p><\/li><\/ul><p class=\"\" data-start=\"7073\" data-end=\"7314\"><strong data-start=\"7073\" data-end=\"7103\">Inad\u00e9quation entre la valve et le signal\u00a0:<\/strong><br data-start=\"7103\" data-end=\"7106\" \/>Si la course de l&#039;actionneur ne correspond pas au signal d&#039;entr\u00e9e, ou si l&#039;actionneur ne peut pas effectuer sa course compl\u00e8te, cela peut indiquer un probl\u00e8me avec le contr\u00f4leur servo ou le circuit du potentiom\u00e8tre de r\u00e9glage de la zone morte.<\/p><p class=\"\" data-start=\"7316\" data-end=\"7402\">Pour obtenir de l&#039;aide suppl\u00e9mentaire, suivez les \u00e9tapes de d\u00e9pannage d\u00e9crites pour chaque code d&#039;erreur.<\/p><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>1. Installation de l&#039;actionneur sur la vanne\u00a0: Suivez les instructions d&#039;installation d\u00e9crites dans la section \u00ab\u00a0Comment installer l&#039;actionneur sur la vanne\u00a0\u00bb pour installer correctement l&#039;actionneur sur la vanne. V\u00e9rifiez le bon fonctionnement en testant manuellement le mouvement de la vanne. 2. R\u00e9glage des but\u00e9es m\u00e9caniques en position ferm\u00e9e\u00a0: Utilisez le volant pour amener la vanne en position ferm\u00e9e.<\/p>","protected":false},"author":1,"featured_media":10944,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[100],"tags":[53],"class_list":["post-5308","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-how-to-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/fr_be\/wp-json\/wp\/v2\/posts\/5308","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/fr_be\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/fr_be\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/fr_be\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/fr_be\/wp-json\/wp\/v2\/comments?post=5308"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/fr_be\/wp-json\/wp\/v2\/posts\/5308\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/fr_be\/wp-json\/wp\/v2\/media\/10944"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/fr_be\/wp-json\/wp\/v2\/media?parent=5308"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/fr_be\/wp-json\/wp\/v2\/categories?post=5308"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/fr_be\/wp-json\/wp\/v2\/tags?post=5308"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}