{"id":9985,"date":"2025-02-10T03:28:44","date_gmt":"2025-02-10T03:28:44","guid":{"rendered":"https:\/\/dclcontrols.com\/?p=9985"},"modified":"2025-03-28T10:36:19","modified_gmt":"2025-03-28T10:36:19","slug":"fsr-um","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/et_ee\/tugi\/um-ajam\/fsr-um","title":{"rendered":"DCL-ajami ja FSR-iga kasutusjuhend"},"content":{"rendered":"<p><strong>DCL-ajam FSR-iga<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium alignleft\" src=\"https:\/\/dclcontrols.com\/dam\/actuator\/fsr\/images\/dcl-actuator-with-fsr.webp\" width=\"6912\" height=\"5028\" \/><\/p>\n<h5>Juhtpaneel<\/h5>\n<p><img decoding=\"async\" class=\"size-medium alignleft\" src=\"https:\/\/dclcontrols.com\/dam\/actuator\/fsr\/images\/dcl-actuator-fsr-panel.webp\" width=\"1920\" height=\"1964\" \/><\/p>\n<ul>\n<li><strong>\u00dchendus<\/strong>\n<p><strong>P1<\/strong>\uff1aDC24V toide +<\/p>\n<p><strong>P3<\/strong>DC24V toide \u2013<\/p>\n<p><strong>P5<\/strong>Sisend 4\u201320 mA<\/p>\n<p><strong>P7<\/strong>Sisend 4\u201320 mA +<\/p>\n<p><strong>P9<\/strong>V\u00e4ljund 4\u201320 mA<\/p>\n<p><strong>P11<\/strong>V\u00e4ljund 4\u201320 mA +<\/p>\n<p><strong>P2<\/strong>SISSE\/V\u00c4LJA Sisend COM<\/p>\n<p><strong>P4<\/strong>ON\/OFF sisend avatud<\/p>\n<p><strong>P6<\/strong>ON\/OFF sisendi sulgemine<\/p>\n<p><strong>P8<\/strong>SISSE\/V\u00c4LJA v\u00e4ljund COM<\/p>\n<p><strong>P10<\/strong>ON\/OFF v\u00e4ljund avatud<\/p>\n<p><strong>P12<\/strong>ON\/OFF v\u00e4ljund sulgemine<\/li>\n<li><strong>Nupp<\/strong>\n<p><strong>KO<\/strong>: Kasutatakse seadistusre\u017eiimis. Vajutage seda nuppu ajami avamiseks.<br \/>\nPeatamiseks vajutage samaaegselt nuppe \u201eSet\u201c ja \u201eOpen\u201c.<br \/>\nseadke t\u00e4ielikult avatud asend.<\/p>\n<p><strong>KC:<\/strong> Kasutatakse seadistusre\u017eiimis. Vajutage seda nuppu ajami sulgemiseks.<br \/>\npeatamiseks vajutage samaaegselt nuppe \u201eSet\u201c ja \u201eShut\u201c.<br \/>\nm\u00e4\u00e4rake t\u00e4ielikult suletud asend.<\/p>\n<p><strong>KS:<\/strong> Kasutatakse seadistusre\u017eiimis. Kasutage seda nuppu koos<br \/>\nteised parameetrite konfigureerimiseks.<\/li>\n<li><strong>L\u00fcliti<\/strong>\n<p><strong>L\u00f5una-Aafrika Vabariik<\/strong>: T\u00f6\u00f6re\u017eiimi m\u00e4\u00e4ramine (vaikimisi on seatud v\u00e4\u00e4rtusele 1):<\/li>\n<\/ul>\n<blockquote><p><strong>1<\/strong>\u2013Normaalne modulatsioon <strong>2<\/strong>\u2013Seadistusre\u017eiim <strong>3<\/strong>\u2013P\u00f6\u00f6rdmodulatsioon<\/p><\/blockquote>\n<p><strong>SB<\/strong>Ohutusasendi m\u00e4\u00e4ramine (vaikimisi on seatud v\u00e4\u00e4rtusele 1):<\/p>\n<blockquote><p><strong>1<\/strong>\u2013S\u00f5ida t\u00e4ielikult avatud asendisse <strong>2<\/strong>\u2013Hoia positsiooni <strong>3<\/strong>\u2013S\u00f5ida t\u00e4ielikult<br \/>\nSulge<\/p><\/blockquote>\n<ul>\n<li><strong>N\u00e4idustus<\/strong>\n<p><strong>L1<\/strong>Roheline, toiteindikaator;<\/p>\n<p><strong>L2<\/strong>Punane, sisendsignaali viga, s\u00fcttib, kui sisendsignaal on l\u00e4bi<br \/>\nvahemik;<\/p>\n<p><strong>L3<\/strong>Punane, potentsiomeetri viga, s\u00fcttib, kui potentsiomeeter on<br \/>\nebanormaalne v\u00f5i \u00fchendusjuhe on katki;<\/p>\n<p><strong>L4<\/strong>Punane, kinnij\u00e4\u00e4nud veateade, s\u00fcttib, kui ajamit ei saa k\u00e4ivitada<br \/>\navamiseks v\u00f5i sulgemiseks.<\/li>\n<\/ul>\n<p><strong>Seaded<\/strong><\/p>\n<blockquote><p>Seadistusre\u017eiimi sisenemiseks l\u00fclitage SA asendisse 2. Seej\u00e4rel saate seadistada<br \/>\nt\u00f6\u00f6 p\u00f6\u00f6rlemisvahemik, ohutusasendi m\u00e4\u00e4ramine, sisendi kalibreerimine<br \/>\nja v\u00e4ljundsignaal jne.<\/p><\/blockquote>\n<ul>\n<li><strong>T\u00f6\u00f6ulatus<\/strong>\n<p><strong>T\u00e4ielikult suletud asendi konfigureerimine<\/strong>\uff1a<\/li>\n<\/ul>\n<ol>\n<li>Vajutage ventiili t\u00e4ielikuks sulgemiseks nuppu Ava\/Sulge.<br \/>\npositsioon.<\/li>\n<li>Hoidke all nuppu Set ja seej\u00e4rel nuppu Shut, kuni L2 on sisse l\u00fclitatud.<br \/>\numbes 3-4 sekundit hiljem, mis t\u00e4hendab t\u00e4ielikku suletud asendit<br \/>\nkonfiguratsioon on tehtud.<\/li>\n<li>N\u00fc\u00fcd saate need kaks nuppu vabastada.\n<p><strong>T\u00e4ielikult avatud asendi konfigureerimine<\/strong>\uff1a<\/li>\n<\/ol>\n<p><!-- --><\/p>\n<ol>\n<li>Vajutage ventiili t\u00e4ielikuks avamiseks nuppu Ava\/Sulge.<br \/>\npositsioon.<\/li>\n<li>Hoidke all nuppu Set ja seej\u00e4rel nuppu Open, kuni L2 s\u00fcttib.<br \/>\numbes 3-4 sekundit hiljem, mis t\u00e4hendab t\u00e4ielikult avatud asendit<br \/>\nkonfiguratsioon on tehtud.<\/li>\n<li>N\u00fc\u00fcd saate need kaks nuppu vabastada.\n<p><em>[M\u00e4rkus: Kui t\u00e4ielikult avatud ja suletud asend konfigureeriti<br \/>\nsamas asendis, siis seadistamine \u00f5nnestub. Aga<br \/>\n]{.underline} ajam ei p\u00f6\u00f6rle modulatsioonire\u017eiimis.<\/em><\/li>\n<\/ol>\n<ul>\n<li><strong>M\u00e4\u00e4rake ohutusasend<\/strong><\/li>\n<\/ul>\n<p>Seadke SB abil soovitud ohutusasend toitekatkestuse korral.<br \/>\nalla v\u00f5i sisendsignaal oli vigane.<\/p>\n<ul>\n<li>Keera SB asendisse 1, et lasta ajamil ventiili t\u00e4ielikult avada.<br \/>\npositsioon.<\/li>\n<li>Keera SB asendisse 2, et ajam hoiaks klapi praegust asendit.<\/li>\n<li>Keera SB asendisse 3, et lasta ajamil ventiili t\u00e4ielikult sulgeda.<br \/>\npositsioon.<\/p>\n<p>See konfiguratsiooni osa on tavaliselt ebavajalik, konfigureerige uuesti<br \/>\nneed, kui see t\u00f5esti loeb.<\/li>\n<\/ul>\n<p><!-- --><\/p>\n<ul>\n<li><strong>4\u201320 mA v\u00e4ljundi kalibreerimine<\/strong><\/li>\n<\/ul>\n<ol>\n<li>Keera SA 2 peale<\/li>\n<li>Voolu j\u00e4lgimiseks \u00fchendage signaali v\u00e4ljundiga ampermeeter.<\/li>\n<li>Hoidke seadistusnuppu all ja seej\u00e4rel avage ja sulgege samaaegselt, kuni L2 on<br \/>\nsisse l\u00fclitatud, mis t\u00e4hendab, et sisenetakse 4mA kalibreerimisre\u017eiimi. N\u00fc\u00fcd saate<br \/>\nv\u00f5iks need 3 nuppu vabastada.<\/li>\n<li>4 mA voolutugevuse reguleerimiseks vajutage nuppu Ava (suurenda) v\u00f5i Sulge (v\u00e4henda).<\/li>\n<li>Hoidke seadistusnuppu all, kuni L2 l\u00fclitub v\u00e4lja ja seej\u00e4rel uuesti sisse.<br \/>\n20 mA kalibreerimise alustamiseks vabastage nupp.<\/li>\n<li>20 mA reguleerimiseks vajutage nuppu Ava (suurenda) v\u00f5i Sulge (v\u00e4henda).<\/li>\n<li>Hoidke seadistusnuppu all, kuni L2 l\u00fclitub v\u00e4lja ja seej\u00e4rel uuesti sisse.<br \/>\nKalibreerimisprotsessi l\u00f5puleviimiseks vabastage nupp.<\/li>\n<\/ol>\n<ul>\n<li><strong>4\u201320 mA sisendi kalibreerimine<\/strong><\/li>\n<\/ul>\n<ol>\n<li>Keera SA 2 peale<\/li>\n<li>\u00dchendage 4-20mA vooluallikas signaali sisendiga, et genereerida<br \/>\nviide.<\/li>\n<li>Hoidke nuppu Set all, kuni L2 hakkab vilkuma, seej\u00e4rel vabastage Set. Hoidke lahti.<br \/>\nja sulguvad samaaegselt, kuni L3 hakkab vilkuma, mis n\u00e4itab<br \/>\nkalibreerimisre\u017eiimi sisenemisel vabastage n\u00fc\u00fcd need kaks nuppu.<\/li>\n<li>Genereerige sisendile 4 mA v\u00f5rdlusvool, hoidke nuppu seatud ja seej\u00e4rel sulgege, kuni L4 on v\u00e4lja l\u00fclitatud.<br \/>\np\u00f5leb, mis n\u00e4itab, et voolu sisend kalibreeriti<br \/>\n4 mA v\u00f5rdlusvool. N\u00fc\u00fcd v\u00f5iksite m\u00f5lemad nupud vabastada.<\/li>\n<li>Genereerige sisendile 20 mA v\u00f5rdlusvool, hoidke nuppu \u201eSet\u201c ja seej\u00e4rel sulgege l\u00fcliti, kuni L4 on v\u00e4lja l\u00fclitatud.<br \/>\np\u00f5leb, mis n\u00e4itab, et voolu sisend kalibreeriti vastavalt<br \/>\n20 mA v\u00f5rdlusvool. N\u00fc\u00fcd v\u00f5iksite m\u00f5lemad nupud vabastada.<\/li>\n<li>Hoidke nuppu Set all, kuni L3 l\u00f5petab vilkumise, mis n\u00e4itab kalibreerimise toimumist<br \/>\nl\u00f5petatud.<\/li>\n<\/ol>\n<p><strong>Hakka kasutama<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignleft size-medium\" src=\"https:\/\/dclcontrols.com\/dam\/actuator\/fsr\/images\/dcl-actuator-fsr-plug.webp\" width=\"1920\" height=\"2083\" \/><\/p>\n<ul>\n<li><strong>Modulatsioon 4\u201320 mA voolutugevusega<\/strong><\/li>\n<\/ul>\n<p>Modulatsiooni alustamiseks keerake SA v\u00e4\u00e4rtusele 1.<\/p>\n<ul>\n<li>T\u00e4iturmehhanism liigutab ventiili kindlasse asendisse vastavalt<br \/>\n4-20mA sisendsignaal on m\u00e4\u00e4ratud.<\/li>\n<li>4-20mA v\u00e4ljundsignaal v\u00e4ljastab klapi asendi reaalses asendis.<br \/>\naeg.<\/li>\n<li>\u201eSISSE\/V\u00c4LJA v\u00e4ljund avatud\u201d v\u00e4ljastab signaali (\u00fchenda COM-iga), kui<br \/>\nventiil viidi t\u00e4ielikult avatud asendisse.<\/li>\n<li>\u201eSISSE\/V\u00c4LJA v\u00e4ljundi sulgemine\u201d annab signaali (\u00fchenda COM-pordiga), kui<br \/>\nventiil viidi t\u00e4ielikult suletud asendisse.<\/li>\n<li>T\u00e4iturmootor viib ventiili ohutusasendisse, kui toide on sisse l\u00fclitatud.<br \/>\nVoolukatkestus v\u00f5i sisendsignaal oli vigane.<\/li>\n<li>P\u00e4rast toite sissel\u00fclitamist naaseb ajam modulatsioonire\u017eiimi ja<br \/>\nsisendsignaal taastati.<\/p>\n<p><em>[M\u00e4rkus: P\u00f6\u00f6rdtoimingu aktiveerimiseks v\u00f5ite SA v\u00e4\u00e4rtuseks 3 keerata.]<br \/>\nmille puhul 4 mA sisendv\u00e4\u00e4rtus edastatakse 20 mA-na ja 20 mA edastatakse<br \/>\nedastatakse 4 mA-na. Seega on modulatsioon t\u00e4pselt selline<br \/>\n\u00fcmberp\u00f6\u00f6ratud.]{.allajoonitud}<\/em><\/p>\n<p><img decoding=\"async\" src=\"media\/image4.png\" alt=\"1714094198309\" \/>{width=&quot;6,720833333333333&quot;<br \/>\nk\u00f5rgus =\u201d1,0701388888888889 tolli\u201d}<\/li>\n<\/ul>\n<p><!-- --><\/p>\n<ul>\n<li><strong>SISSE\/V\u00c4LJA passiivse digitaalsisendiga<\/strong><\/li>\n<\/ul>\n<p>Modulatsiooni alustamiseks keerake SA v\u00e4\u00e4rtusele 1.<\/p>\n<ul>\n<li>T\u00e4iturmehhanism viib ventiili t\u00e4ielikult avatud asendisse, kui<br \/>\n\u201eSISSE\/V\u00c4LJA v\u00e4ljund avatud\u201d oli aktiivne (\u00fchenda COM-iga).<\/li>\n<li>T\u00e4iturmehhanism viib ventiili t\u00e4ielikult suletud asendisse, kui<br \/>\n\u201eSISSE\/V\u00c4LJA v\u00e4ljundi sulgemine\u201d toimis (\u00fchenda COM-iga).<\/li>\n<li>\u201eSISSE\/V\u00c4LJA v\u00e4ljund avatud\u201d v\u00e4ljastab signaali (\u00fchenda COM-iga), kui<br \/>\nventiil viidi t\u00e4ielikult avatud asendisse.<\/li>\n<li>\u201eSISSE\/V\u00c4LJA v\u00e4ljundi sulgemine\u201d annab signaali (\u00fchenda COM-pordiga), kui<br \/>\nventiil viidi t\u00e4ielikult suletud asendisse.<\/li>\n<li>4-20mA v\u00e4ljundsignaal v\u00e4ljastab klapi asendi reaalses asendis.<br \/>\naeg.<\/li>\n<li>T\u00e4iturmootor viib ventiili ohutusasendisse, kui toide on sisse l\u00fclitatud.<br \/>\nv\u00f5im oli katkenud.<\/li>\n<li>P\u00e4rast toite v\u00e4ljal\u00fclitamist naaseb ajam modulatsioonire\u017eiimi.<br \/>\ntaastunud.<\/li>\n<\/ul>\n<p><!-- --><\/p>\n<ul>\n<li><strong>Modulatsioon Modbus-RTU\/RS485 abil<\/strong><\/li>\n<\/ul>\n<p>Lisateabe saamiseks v\u00f5tke meiega \u00fchendust\u2026<\/p>\n<p><strong>Veaindikaator<\/strong><\/p>\n<ul>\n<li><strong>L2: Sisendsignaali viga<\/strong>\n<p>Sisendsignaal on katkenud v\u00f5i j\u00e4\u00e4b vahemikust v\u00e4lja (&lt;2,5 mA v\u00f5i &gt; 21,5 mA)<\/li>\n<li><strong>L3: Asukoha m\u00f5\u00f5tmise viga<\/strong>\n<p>Potentsiomeeter v\u00f5i \u00fchendusjuhe on katki<\/li>\n<li><strong>L4: Kinnij\u00e4\u00e4nud viga<\/strong>\n<p>Ventiil oli kinni kiilunud ja ajam ei saanud ventiili asendisse viia.<br \/>\neeldatav positsioon.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>DCL-ajam FSR-i juhtpaneeli \u00fchendusega P1: DC24V toide + P3: DC24V toide \u2013 P5: 4-20mA sisend \u2013 P7: 4-20mA sisend + P9: 4-20mA v\u00e4ljund \u2013 P11: 4-20mA v\u00e4ljund + P2: ON\/OFF sisend COM P4: ON\/OFF sisend avatud P6: ON\/OFF sisend suletud P8: ON\/OFF v\u00e4ljund COM P10: ON\/OFF v\u00e4ljund avatud P12: ON\/OFF v\u00e4ljund sulgemise nupp KO: Kasutatakse seadistusre\u017eiimis. Vajutage seda nuppu, et avada [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[9],"tags":[],"class_list":["post-9985","post","type-post","status-publish","format-standard","hentry","category-um-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/et_ee\/wp-json\/wp\/v2\/posts\/9985","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/et_ee\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/et_ee\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/et_ee\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/et_ee\/wp-json\/wp\/v2\/comments?post=9985"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/et_ee\/wp-json\/wp\/v2\/posts\/9985\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/et_ee\/wp-json\/wp\/v2\/media?parent=9985"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/et_ee\/wp-json\/wp\/v2\/categories?post=9985"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/et_ee\/wp-json\/wp\/v2\/tags?post=9985"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}