{"id":6077,"date":"2023-08-10T15:42:35","date_gmt":"2023-08-10T07:42:35","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6077"},"modified":"2025-03-31T08:09:15","modified_gmt":"2025-03-31T08:09:15","slug":"how-actuator-with-bus-works","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/es_cl\/apoyo\/el-actuador\/como-funciona-un-actuador-con-bus","title":{"rendered":"C\u00f3mo funcionan los actuadores con funciones de bus: Modbus, CAN, Ethernet, Profibus"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6077\" class=\"elementor elementor-6077\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-05aec29 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"05aec29\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4dc31e3\" data-id=\"4dc31e3\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-11f2047 elementor-widget elementor-widget-text-editor\" data-id=\"11f2047\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0Al instalar una v\u00e1lvula de control el\u00e9ctrica DCL con funcionalidad de bus en una tuber\u00eda, puede controlar un conjunto de v\u00e1lvulas de control el\u00e9ctricas a trav\u00e9s del bus (Modbus, CAN, Ethernet, Profibus) para lograr un control sincronizado del grupo de v\u00e1lvulas.<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone\" src=\"\/wp-content\/uploads\/2023\/08\/actuator-with-bus-application.webp\" alt=\"Uso del control por bus para actuadores DCL\" width=\"1000\" height=\"555\" \/><\/p><ul><li>El sistema de control se comunica con el actuador mediante un protocolo de comunicaci\u00f3n por bus, enviando comandos para controlar la posici\u00f3n de la v\u00e1lvula. El actuador mueve la v\u00e1lvula a la posici\u00f3n especificada seg\u00fan los comandos del bus.<\/li><li>Si se produce un error en el bus, el actuador accionar\u00e1 la v\u00e1lvula para abrirla completamente, cerrarla completamente o mantener la posici\u00f3n de la v\u00e1lvula seg\u00fan la configuraci\u00f3n del usuario durante el error del bus.<\/li><li>Si se interrumpe el suministro el\u00e9ctrico al actuador durante el funcionamiento de la v\u00e1lvula, el actuador se detendr\u00e1 y la v\u00e1lvula el\u00e9ctrica permanecer\u00e1 en su posici\u00f3n actual.<\/li><\/ul><p><strong>Nota:<\/strong> El diagrama de circuito anterior muestra el funcionamiento b\u00e1sico de un actuador de tipo interruptor (v\u00e1lvula el\u00e9ctrica). En aplicaciones pr\u00e1cticas, tambi\u00e9n deben considerarse componentes de protecci\u00f3n adicionales, como fusibles y limitadores de corriente.<\/p><p><strong>Tres estados<\/strong><\/p><figure style=\"width: 422px\" class=\"wp-caption alignnone\"><img decoding=\"async\" src=\"\/dam\/downloads\/user-manual\/vale-closed.webp\" alt=\"V\u00e1lvula el\u00e9ctrica cerrada\" width=\"422\" height=\"388\" \/><figcaption class=\"wp-caption-text\">V\u00e1lvula el\u00e9ctrica cerrada<\/figcaption><\/figure><figure style=\"width: 487px\" class=\"wp-caption alignnone\"><img decoding=\"async\" src=\"\/dam\/tech\/images\/vale-opening.webp\" alt=\"Regulaci\u00f3n del flujo\" width=\"487\" height=\"378\" \/><figcaption class=\"wp-caption-text\">Regulaci\u00f3n del flujo<\/figcaption><\/figure><figure style=\"width: 466px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" src=\"\/dam\/downloads\/user-manual\/vale-open.webp\" alt=\"V\u00e1lvula el\u00e9ctrica completamente abierta\" width=\"466\" height=\"388\" \/><figcaption class=\"wp-caption-text\">V\u00e1lvula el\u00e9ctrica completamente abierta<\/figcaption><\/figure><p>\u00a0<\/p><p>\u00a0<\/p><p><strong>Obt\u00e9n m\u00e1s informaci\u00f3n sobre<\/strong><\/p><p><a href=\"\/es_cl\/apoyo\/actuador-um\/um-sf-zc-modbus\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" src=\"\/dam\/tech\/images\/modbus-rs485.webp\" width=\"269\" height=\"159\" \/><\/a><\/p><p><a href=\"\/es_cl\/apoyo\/actuador-um\/um-sf-zc-modbus\/\"><span style=\"text-decoration: underline;\">Control de actuadores el\u00e9ctricos DCL mediante Modbus\/RS485<\/span><\/a><\/p><p>\u00a0<\/p><p><a href=\"\/es_cl\/apoyo\/actuador-um\/dc-fb3\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" src=\"\/dam\/tech\/images\/modbus-tcpip.webp\" width=\"249\" height=\"147\" \/><\/a><br \/><a href=\"\/es_cl\/apoyo\/actuador-um\/dc-fb3\/\"><span style=\"text-decoration: underline;\">Control de actuadores el\u00e9ctricos DCL mediante Modbus\/TCP-IP<\/span><\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u00a0When you install a DCL electric control valve with bus functionality on a pipeline, you can control a set of electric control valves through the bus (Modbus, CAN, Ethernet, Profibus) to achieve synchronized control of the valve cluster. The control system communicates with the actuator via a bus communication protocol, sending commands to control the [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[8],"tags":[53,66,62,57,64,52,65],"class_list":["post-6077","post","type-post","status-publish","format-standard","hentry","category-ta-acutator","tag-actuator","tag-explosion-proof-actuator","tag-first-step","tag-general-actuator","tag-modulating-actuator","tag-fast-move-actuator","tag-very-small-actuator-tag"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/es_cl\/wp-json\/wp\/v2\/posts\/6077","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/es_cl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/es_cl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/es_cl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/es_cl\/wp-json\/wp\/v2\/comments?post=6077"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/es_cl\/wp-json\/wp\/v2\/posts\/6077\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/es_cl\/wp-json\/wp\/v2\/media?parent=6077"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/es_cl\/wp-json\/wp\/v2\/categories?post=6077"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/es_cl\/wp-json\/wp\/v2\/tags?post=6077"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}