{"id":6034,"date":"2023-08-03T20:40:54","date_gmt":"2023-08-03T12:40:54","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6034"},"modified":"2025-03-27T09:36:11","modified_gmt":"2025-03-27T09:36:11","slug":"dcl-02-modulating-actuator","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/de_at\/unterstutzung\/herr-aktuator\/dcl-02-modulationsaktuator","title":{"rendered":"H\u00e4ufige Fehler und Fehlerbehebung bei DCL-02 Modulationsaktuatoren"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6034\" class=\"elementor elementor-6034\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4d0a73a e-con-full e-flex e-con e-parent\" data-id=\"4d0a73a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-074db40 e-con-full e-flex e-con e-child\" data-id=\"074db40\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c0eba31 elementor-widget elementor-widget-text-editor\" data-id=\"c0eba31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Diese Anleitung gilt f\u00fcr die ultrakleinen Modulationsaktuatoren der DCL-Serie, Modell wie folgt:<\/p><p>DCL-02E<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-baf5aaf elementor-widget elementor-widget-image\" data-id=\"baf5aaf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-02-valve.webp\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4622d9 elementor-widget elementor-widget-heading\" data-id=\"b4622d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">H\u00e4ufige Fehler und Methoden zur Fehlerbehebung<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e06e825 elementor-widget elementor-widget-text-editor\" data-id=\"e06e825\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>\u00a0<\/h3><table><thead><tr><th><strong>Fehler<\/strong><\/th><th><strong>M\u00f6gliche Ursache<\/strong><\/th><th><strong>Fehlerbehebungsmethode<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>Der Aktor \u00f6ffnet oder schlie\u00dft beim Start nicht.<\/strong><\/td><td>1. Falsche Verkabelung<\/td><td>\u00dcberpr\u00fcfen Sie die Verkabelung anhand des Schaltplans des Aktuators, um sicherzustellen, dass sie korrekt ist.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Falsche Stromversorgung<\/td><td>Stellen Sie sicher, dass die Ausgangsspannung des Netzteils innerhalb von \u00b110% der Nennspannung des Aktuators liegt und der Strom das Dreifache des Nennstroms des Aktuators betr\u00e4gt.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Fehlerhafter Steuerschalter oder Relais<\/td><td>Messen Sie mit einem Multimeter die Eingangsspannung am Schaltanschluss des Aktuators, um sicherzustellen, dass sie dem erwarteten Wert entspricht.<\/td><\/tr><tr><td>\u00a0<\/td><td>4. Fehlanpassung des Steuerungssystems<\/td><td>Verwenden Sie einen mechanischen Schalter, um die Funktionsf\u00e4higkeit des Aktuators zu testen. Wenn der Aktuator ordnungsgem\u00e4\u00df funktioniert, \u00fcberpr\u00fcfen Sie die Ausgangslogik des Steuerungssystems.<\/td><\/tr><tr><td>\u00a0<\/td><td>5. Mehrere Aktuatoren oder Parallelschaltung von Aktuatoren mit anderen Ger\u00e4ten<\/td><td>Schaltaktoren ben\u00f6tigen einen Kondensator. Die Parallelschaltung mit anderen Ger\u00e4ten beeinflusst die Kapazit\u00e4t des Kondensators. Schaltaktoren sollten nur einzeln, nicht parallel, angesteuert werden.<\/td><\/tr><tr><td><strong>Der Aktor kann nur \u00f6ffnen oder schlie\u00dfen<\/strong><\/td><td>1. Falsche Verkabelung<\/td><td>1. Verwenden Sie einen mechanischen Schalter, um die Funktionsf\u00e4higkeit des Aktuators zu testen. Wenn er ordnungsgem\u00e4\u00df funktioniert, \u00fcberpr\u00fcfen Sie die Ausgangslogik des Steuerungssystems.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. \u00dcberpr\u00fcfen Sie die Verkabelung anhand des Schaltplans des Aktuators.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Falsche Einstellung der Nockenwelle (vollst\u00e4ndig ge\u00f6ffnet\/vollst\u00e4ndig geschlossen).<\/td><td>Informationen zur korrekten Nockenpositionierung finden Sie im Abschnitt \u201eEinstellen von elektrischen Ventilen mit Schalter\u201c.<\/td><\/tr><tr><td><strong>Aktor stoppt mitten im Hub<\/strong><\/td><td>1. Ventilblockierung<\/td><td>Pr\u00fcfen Sie, ob das Ventil blockiert ist, beseitigen Sie die Blockade und versuchen Sie es erneut, nachdem der \u00dcberlastschutz des Stellantriebs abgek\u00fchlt ist.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Feste Partikel in der Fl\u00fcssigkeit, die ein Blockieren des Ventils verursachen.<\/td><td>Pr\u00fcfen Sie, ob feste Partikel in der Fl\u00fcssigkeit das Ventil blockieren, beseitigen Sie die Verstopfung und versuchen Sie es erneut, nachdem der \u00dcberlastschutz des Aktuators abgek\u00fchlt ist.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Falsche Einstellung des Anschlagblocks f\u00fcr vollst\u00e4ndiges \u00d6ffnen\/vollst\u00e4ndiges Schlie\u00dfen<\/td><td>Beachten Sie die Hinweise zur korrekten Einstellung der Absperrblockposition in der Rubrik \u201eEinstellen von elektrischen Ventilen mit Schalter\u201c.<\/td><\/tr><tr><td><strong>Der Aktuator l\u00e4sst sich nicht mit dem Griff drehen.<\/strong><\/td><td>1. Feste Partikel in der Fl\u00fcssigkeit, die zum Festfressen des Ventils f\u00fchren<\/td><td>Pr\u00fcfen Sie, ob feste Partikel das Ventil blockieren, beseitigen Sie die Verstopfung und versuchen Sie es erneut, nachdem der \u00dcberlastschutz des Stellantriebs abgek\u00fchlt ist.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Das Ventil klemmt.<\/td><td>Pr\u00fcfen Sie, ob das Ventil klemmt, beseitigen Sie die Blockade und versuchen Sie es erneut, nachdem der \u00dcberlastschutz des Stellantriebs abgek\u00fchlt ist.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Der Verz\u00f6gerungsmechanismus des Aktuators ist besch\u00e4digt.<\/td><td>Entfernen Sie den Stellantrieb vom Ventil und drehen Sie den Griff. L\u00e4sst er sich nicht drehen, ersetzen Sie ihn durch einen neuen Stellantrieb.<\/td><\/tr><tr><td><strong>Kein Ausgang vom Positionsr\u00fcckmeldesignal<\/strong><\/td><td>1. Falsche Schalterverdrahtung<\/td><td>\u00dcberpr\u00fcfen Sie die Verkabelung anhand des Schaltplans des Aktuators, um sicherzustellen, dass sie korrekt ist.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Falsche Einstellung der Nockenwelle (vollst\u00e4ndig ge\u00f6ffnet\/vollst\u00e4ndig geschlossen).<\/td><td>Beachten Sie die Hinweise zur korrekten Einstellung der Nockenposition unter \u201eSo stellen Sie elektrische Schalterventile ein\u201c.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. \u00dcberstrom verursacht Ausfall des Positionsr\u00fcckmeldeschalters<\/td><td>1. Lesen Sie im Abschnitt \u201eEinstellen von elektrischen Ventilen mit Schalter\u201c nach, ob der Nocken f\u00fcr vollst\u00e4ndiges \u00d6ffnen\/vollst\u00e4ndiges Schlie\u00dfen den Positionsr\u00fcckmeldeschalter ordnungsgem\u00e4\u00df bet\u00e4tigt.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. Pr\u00fcfen Sie, ob der Positionsr\u00fcckkopplungskreis angeschlossen ist.<\/td><\/tr><\/tbody><\/table><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6802156 elementor-widget elementor-widget-heading\" data-id=\"6802156\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2. \u00dcberpr\u00fcfen Sie die Anwendungsbedingungen auf Kompatibilit\u00e4t<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be9bb57 elementor-widget elementor-widget-text-editor\" data-id=\"be9bb57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5234\" data-end=\"5479\">Elektrische Stellantriebe k\u00f6nnen ausfallen, wenn sie unsachgem\u00e4\u00df oder unter falschen Anwendungsbedingungen eingesetzt werden. Die Einhaltung der im Produktdatenblatt definierten Spezifikationen tr\u00e4gt zu einem langfristigen und st\u00f6rungsfreien Betrieb bei.<\/p><ul data-start=\"5481\" data-end=\"6708\" data-is-only-node=\"\"><li class=\"\" data-start=\"5481\" data-end=\"5667\"><p class=\"\" data-start=\"5483\" data-end=\"5667\"><strong data-start=\"5483\" data-end=\"5507\">Versorgungsspannung<\/strong>Die Spannung des Netzteils muss innerhalb des Nennbetriebsspannungsbereichs des Aktuators liegen. \u00dcber- oder Unterspannung kann die Lebensdauer des Aktuators verk\u00fcrzen.<\/p><\/li><li class=\"\" data-start=\"5671\" data-end=\"5866\"><p class=\"\" data-start=\"5673\" data-end=\"5866\"><strong data-start=\"5673\" data-end=\"5697\">Stromversorgung<\/strong>Da der Anlaufstrom des Motors viel h\u00f6her ist als der Nennstrom, muss sichergestellt werden, dass das Netzteil eine Nennstromkapazit\u00e4t von mindestens dem Dreifachen des Nennstroms des Aktuators aufweist.<\/p><\/li><li class=\"\" data-start=\"5868\" data-end=\"6082\"><p class=\"\" data-start=\"5870\" data-end=\"6082\"><strong data-start=\"5870\" data-end=\"5885\">Temperatur<\/strong>Stellen Sie sicher, dass der Aktor innerhalb seines Nenntemperaturbereichs arbeitet. Der Betrieb des Aktors au\u00dferhalb des Nenntemperaturbereichs kann zu Fehlfunktionen oder verk\u00fcrzter Lebensdauer und letztendlich zum Ausfall f\u00fchren.<\/p><\/li><li class=\"\" data-start=\"6084\" data-end=\"6498\"><p class=\"\" data-start=\"6086\" data-end=\"6498\"><strong data-start=\"6086\" data-end=\"6101\">Umfeld<\/strong>DCL-Schaltaktuatoren sind gem\u00e4\u00df IP67 witterungsbest\u00e4ndig und eignen sich f\u00fcr den Innen- und Au\u00dfenbereich. Sie bieten Schutz vor Regen, Spritzwasser und UV-Strahlung (Sonnenlicht), was die Lebensdauer des Produkts in der Regel verl\u00e4ngert. In stark korrosiven Umgebungen k\u00f6nnen die elektronischen Bauteile jedoch vorzeitig ausfallen. Nicht explosionsgesch\u00fctzte Aktuatoren d\u00fcrfen nicht in explosionsgef\u00e4hrdeten Bereichen eingesetzt werden.<\/p><\/li><li class=\"\" data-start=\"6500\" data-end=\"6708\"><p class=\"\" data-start=\"6502\" data-end=\"6708\"><strong data-start=\"6502\" data-end=\"6516\">Tastverh\u00e4ltnis<\/strong>Der DCL-Schaltantrieb hat ein Tastverh\u00e4ltnis von 70% (42 Sekunden Betrieb, gefolgt von 18 Sekunden Pause). Wird dieses Tastverh\u00e4ltnis \u00fcberschritten, kann der Motor in den thermischen Schutzmodus schalten.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-823dd6a elementor-widget elementor-widget-heading\" data-id=\"823dd6a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00dcberpr\u00fcfen Sie die Verkabelung des Aktuators.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-32ec269 elementor-widget elementor-widget-text-editor\" data-id=\"32ec269\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"41\" data-end=\"104\">Um einen ordnungsgem\u00e4\u00dfen Betrieb des Aktuators zu gew\u00e4hrleisten, befolgen Sie diese Schritte:<\/p><ol data-start=\"106\" data-end=\"1403\"><li class=\"\" data-start=\"106\" data-end=\"331\"><p class=\"\" data-start=\"109\" data-end=\"156\"><strong data-start=\"109\" data-end=\"156\">\u00dcberpr\u00fcfen Sie die Verkabelung anhand des Schaltplans:<\/strong><\/p><ul data-start=\"160\" data-end=\"331\"><li class=\"\" data-start=\"160\" data-end=\"237\"><p class=\"\" data-start=\"162\" data-end=\"237\">\u00dcberpr\u00fcfen Sie die Verkabelung sorgf\u00e4ltig, um sicherzustellen, dass sie mit dem Schaltplan des Aktuators \u00fcbereinstimmt.<\/p><\/li><li class=\"\" data-start=\"241\" data-end=\"327\"><p class=\"\" data-start=\"243\" data-end=\"327\">Vergewissern Sie sich, dass alle Verbindungen fest sitzen und keine Dr\u00e4hte lose oder getrennt sind.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"332\" data-end=\"558\"><p class=\"\" data-start=\"335\" data-end=\"366\"><strong data-start=\"335\" data-end=\"366\">Auf korrekte Polarit\u00e4t pr\u00fcfen:<\/strong><\/p><ul data-start=\"370\" data-end=\"558\"><li class=\"\" data-start=\"370\" data-end=\"483\"><p class=\"\" data-start=\"372\" data-end=\"483\">Stellen Sie sicher, dass die positiven und negativen Anschl\u00fcsse des Netzteils mit den richtigen Anschl\u00fcssen des Aktuators verbunden sind.<\/p><\/li><li class=\"\" data-start=\"487\" data-end=\"558\"><p class=\"\" data-start=\"489\" data-end=\"558\">Eine falsche Polarit\u00e4t kann zu Fehlfunktionen oder Besch\u00e4digungen des Aktuators f\u00fchren.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"560\" data-end=\"787\"><p class=\"\" data-start=\"563\" data-end=\"601\"><strong data-start=\"563\" data-end=\"601\">\u00dcberpr\u00fcfen Sie die Steuersignalverkabelung:<\/strong><\/p><ul data-start=\"605\" data-end=\"787\"><li class=\"\" data-start=\"605\" data-end=\"687\"><p class=\"\" data-start=\"607\" data-end=\"687\">\u00dcberpr\u00fcfen Sie die Verdrahtung f\u00fcr die Steuersignale (z. B. Eingangssignal, R\u00fcckkopplungssignal).<\/p><\/li><li class=\"\" data-start=\"691\" data-end=\"787\"><p class=\"\" data-start=\"693\" data-end=\"787\">Stellen Sie sicher, dass die Signalleitungen korrekt angeschlossen sind und keine Kurzschl\u00fcsse oder Unterbrechungen aufweisen.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"789\" data-end=\"1011\"><p class=\"\" data-start=\"792\" data-end=\"816\"><strong data-start=\"792\" data-end=\"816\">Erdung pr\u00fcfen:<\/strong><\/p><ul data-start=\"820\" data-end=\"1011\"><li class=\"\" data-start=\"820\" data-end=\"929\"><p class=\"\" data-start=\"822\" data-end=\"929\">Um elektrische St\u00f6rungen oder m\u00f6gliche Kurzschl\u00fcsse zu vermeiden, muss eine ordnungsgem\u00e4\u00dfe Erdung des Aktuators sichergestellt werden.<\/p><\/li><li class=\"\" data-start=\"933\" data-end=\"1011\"><p class=\"\" data-start=\"935\" data-end=\"1011\">Eine fehlerhafte Erdung kann zu unregelm\u00e4\u00dfigem Verhalten oder Funktionsausf\u00e4llen f\u00fchren.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"1013\" data-end=\"1212\"><p class=\"\" data-start=\"1016\" data-end=\"1063\"><strong data-start=\"1016\" data-end=\"1063\">\u00dcberpr\u00fcfen Sie die Verkabelung f\u00fcr externe Komponenten:<\/strong><\/p><ul data-start=\"1067\" data-end=\"1212\"><li class=\"\" data-start=\"1067\" data-end=\"1208\"><p class=\"\" data-start=\"1069\" data-end=\"1208\">Wenn externe Ger\u00e4te wie Endschalter, Sensoren oder zus\u00e4tzliche Steuermodule angeschlossen sind, \u00fcberpr\u00fcfen Sie, ob die Verkabelung sicher und korrekt ist.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"1213\" data-end=\"1403\"><p class=\"\" data-start=\"1216\" data-end=\"1245\"><strong data-start=\"1216\" data-end=\"1245\">Testen Sie den Steuerkreis:<\/strong><\/p><ul data-start=\"1249\" data-end=\"1403\"><li class=\"\" data-start=\"1249\" data-end=\"1351\"><p class=\"\" data-start=\"1251\" data-end=\"1351\">Verwenden Sie ein Multimeter, um den Steuerkreis zu \u00fcberpr\u00fcfen, einschlie\u00dflich der Eingangsspannung an den Steuerklemmen.<\/p><\/li><li class=\"\" data-start=\"1355\" data-end=\"1403\"><p class=\"\" data-start=\"1357\" data-end=\"1403\">Pr\u00fcfen Sie, ob der erwartete Spannungsbereich vorhanden ist.<\/p><\/li><\/ul><\/li><\/ol><p class=\"\" data-start=\"1405\" data-end=\"1634\">Nachdem die korrekte Verkabelung \u00fcberpr\u00fcft wurde, testen Sie den Aktuator, um seine einwandfreie Funktion sicherzustellen. Sollten nach der \u00dcberpr\u00fcfung der Verkabelung weiterhin Probleme auftreten, ist m\u00f6glicherweise eine genauere Untersuchung der internen Komponenten des Aktuators erforderlich.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-422047d elementor-widget elementor-widget-template\" data-id=\"422047d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"template.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-template\">\n\t\t\t\t\t<div data-elementor-type=\"section\" data-elementor-id=\"10970\" class=\"elementor elementor-10970\" data-elementor-post-type=\"elementor_library\">\n\t\t\t<div class=\"elementor-element elementor-element-19a6173 e-flex e-con-boxed e-con e-parent\" data-id=\"19a6173\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-984e463 e-con-full e-flex e-con e-child\" data-id=\"984e463\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d08c8ca elementor-widget elementor-widget-heading\" data-id=\"d08c8ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">E - Modulation mit einer Steuereinheit<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e3dcbb5 elementor-widget elementor-widget-image\" data-id=\"e3dcbb5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"400\" height=\"330\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-e.webp\" class=\"attachment-full size-full wp-image-4857\" alt=\"DCL ist eine E-Mail-Adresse\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4396a8e elementor-widget elementor-widget-text-editor\" data-id=\"4396a8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Eingang: 4~20mA \/ 0~10V<\/li><li>Ausgang: 4~20 mA \/ 0~10 V<\/li><\/ul><p>\u00a0<\/p><p><strong>Verbindungsdetails:<\/strong><\/p><ol><li>Anschluss der Wechselstromleitung (AC85-220V) an L und des Neutralleiters an N.<\/li><li>Anschluss einer 4-20mA\/2-10V Eingangssignalquelle vom Steuerungssystem an Eingang-\/+.<\/li><li>Anschluss von Ausgang -\/+ an das System, um die Ventilposition in Echtzeit auszugeben.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ff65758 e-con-full e-flex e-con e-parent\" data-id=\"ff65758\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-d5dc048 e-con-full e-flex e-con e-child\" data-id=\"d5dc048\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-527200f elementor-widget elementor-widget-text-editor\" data-id=\"527200f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Notiz:<\/p><ul><li>Der Schaltkreis im gestrichelten Kasten ist der interne Schaltkreis des Aktuators. Der Schaltkreis au\u00dferhalb des Kastens veranschaulicht die elektrische Verbindung zum Betrieb des Aktuators.<\/li><li>Falls Sie weitere spezielle Anforderungen an die Anschlussschaltung haben, wenden Sie sich bitte an unseren technischen Support.\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-09f9fde elementor-widget elementor-widget-text-editor\" data-id=\"09f9fde\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bei der Fehlersuche vor Ort k\u00f6nnen Sie sich umgehend an unser technisches Serviceteam wenden, um das Problem gemeinsam zu beheben und die L\u00f6sung zu finden.<\/p><p>Kontaktnummer: 13026331611 (Herr Chen)<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Diese Anleitung gilt f\u00fcr die DCL-Ultraklein-Modulationsantriebe, Modell DCL-02E. H\u00e4ufige Fehler und Fehlerbehebungsmethoden Fehler M\u00f6gliche Ursache Fehlerbehebungsmethode Antrieb \u00f6ffnet oder schlie\u00dft beim Start nicht 1. Falsche Verkabelung \u00dcberpr\u00fcfen Sie die Verkabelung anhand des Verdrahtungsplans des Antriebs, um sicherzustellen, dass sie korrekt ist. 2. Falsche Stromversorgung [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[103],"tags":[53],"class_list":["post-6034","post","type-post","status-publish","format-standard","hentry","category-mr-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/de_at\/wp-json\/wp\/v2\/posts\/6034","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/de_at\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/de_at\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/de_at\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/de_at\/wp-json\/wp\/v2\/comments?post=6034"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/de_at\/wp-json\/wp\/v2\/posts\/6034\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/de_at\/wp-json\/wp\/v2\/media?parent=6034"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/de_at\/wp-json\/wp\/v2\/categories?post=6034"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/de_at\/wp-json\/wp\/v2\/tags?post=6034"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}