{"id":9257,"date":"2024-07-05T15:43:31","date_gmt":"2024-07-05T07:43:31","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=9257"},"modified":"2025-03-31T06:18:52","modified_gmt":"2025-03-31T06:18:52","slug":"dc-fb3","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/da_dk\/stotte\/um-aktuator\/dc-fb3","title":{"rendered":"DC-FB3 Brugermanual"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"9257\" class=\"elementor elementor-9257\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-342a362 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"342a362\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-aaa43ff\" data-id=\"aaa43ff\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-41c310b elementor-widget elementor-widget-text-editor\" data-id=\"41c310b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>DC-FB3-modulet, n\u00e5r det er installeret i den elektriske DCL-aktuator, muligg\u00f8r styring af ventilens position ved hj\u00e6lp af Modbus-TCP\/IP. Installationen er vist nedenfor:<\/p><figure style=\"width: 351px\" class=\"wp-caption alignnone\"><img fetchpriority=\"high\" decoding=\"async\" src=\"\/dam\/um\/images\/\/dc-fb3.webp\" alt=\"\" width=\"351\" height=\"406\" \/><figcaption class=\"wp-caption-text\">DC-FB3<\/figcaption><\/figure><h4>\u00a0<\/h4><figure style=\"width: 446px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"\" src=\"\/dam\/um\/images\/dcl-actuator-with-dc-fb3-scaled.webp\" alt=\"\" width=\"446\" height=\"559\" \/><figcaption class=\"wp-caption-text\">DC-FB3 installeret i DCL-aktuatoren<\/figcaption><\/figure><h2><strong>1. Styring af DCL elektrisk aktuator via Modbus-TCP\/IP ved hj\u00e6lp af standardparametre<\/strong><\/h2><p>DC-FB3 er forudkonfigureret i klienttilstand. Ved at bruge standardparametrene for MAC, IP, Gateway, Server og Port kan du styre DCL&#039;s elektriske aktuator via Modbus-TCP\/IP. Standardparametrene er angivet i den bl\u00e5 boks p\u00e5 billedet nedenfor.<\/p><p>N\u00e5r du bruger standardparametrene, kan du springe trin 2 over og forts\u00e6tte direkte til trin 3 ved hj\u00e6lp af Modbus-TCP\/IP til at styre den elektriske DCL-aktuator.<\/p><figure style=\"width: 500px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"\" src=\"\/dam\/um\/images\/dcl-actuator-with-dc-fb3-flag-scaled.webp\" alt=\"\" width=\"500\" height=\"627\" \/><figcaption class=\"wp-caption-text\">DCL Modbus TCP\/IP-aktuator<\/figcaption><\/figure><h2><strong>2. \u00c6ndring af TCP\/IP-netv\u00e6rksparametre<\/strong><\/h2><h3><strong>2.1 Tilslut DC-FB3 til pc ved hj\u00e6lp af DC-FB1 (USB til RS485)<\/strong><\/h3><figure style=\"width: 500px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"\/dam\/um\/images\/\/connect-dc-fb3-to-pc.webp\" alt=\"\" width=\"500\" height=\"374\" \/><figcaption class=\"wp-caption-text\">Tilslutning af DCL-aktuator med Modbus TCP\/IP til computer<\/figcaption><\/figure><p>Ledningsf\u00f8ringen til tilslutning af DC-FB3 er som f\u00f8lger:<\/p><ul><li><p><strong>R\u00f8d boks 1<\/strong>Tilsluttes til AC220V str\u00f8mforsyning.<\/p><\/li><li><p><strong>Gr\u00f8n boks 4<\/strong>Tilslut til RS485-gr\u00e6nsefladen (A\/B) p\u00e5 DC-FB1.<\/p><\/li><li><p><strong>DC-FB1 USB<\/strong>Tilsluttes pc&#039;en.<\/p><\/li><\/ul><p>For yderligere oplysninger, se brugermanualen til DC-FB1.<\/p><h5>\u00a0<\/h5><h3><strong>2.2 Brug konfigurationssoftware p\u00e5 pc til at indstille netv\u00e6rksparametre<\/strong><\/h3><p><strong>Download konfigurationssoftware<\/strong>Installer den n\u00f8dvendige konfigurationssoftware til indstilling af netv\u00e6rksparametrene.<\/p><p><strong>V\u00e6lg korrekt port<\/strong>\u00c5bn konfigurationssoftwaren, v\u00e6lg den korrekte port, og klik p\u00e5 <strong>FORBINDE<\/strong> for at tilslutte til DC-FB3.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/um\/images\/\/dc-fb3-config3.webp\" width=\"681\" height=\"473\" \/><\/p><p>N\u00e5r den er tilsluttet, vil konfigurationssoftwaren automatisk l\u00e6se parametrene fra DC-FB3.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/um\/images\/\/dc-fb3-config2.webp\" width=\"676\" height=\"467\" \/><\/p><p><strong>Skift netv\u00e6rksparametre<\/strong>N\u00e5r du har \u00e6ndret netv\u00e6rksparametrene, skal du klikke p\u00e5 <strong>SPARE<\/strong> for at gemme de opdaterede parametre i DC-FB3.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/um\/images\/\/dc-fb3-config1.webp\" width=\"677\" height=\"472\" \/><\/p><h2><strong>3. Styr DCL-aktuatoren via Modbus-TCP\/IP<\/strong><\/h2><h3><strong>Hardwareforbindelser<\/strong><\/h3><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" src=\"\/dam\/um\/images\/dcl-actuator-with-dc-fb3-flag-scaled.webp\" width=\"500\" height=\"627\" \/><\/p><ul><li>Tilslut AC220V str\u00f8mforsyningen til terminalerne markeret med den r\u00f8de boks 1<\/li><li>S\u00e6t RJ45-stikket i stikket markeret med den gule boks 2<\/li><\/ul><p>Nu kan du styre aktuatoren via Modbus-RTU-kommandoer ved at f\u00f8lge <a href=\"\/da_dk\/stotte\/um-aktuator\/um-sf-zc-modbus\/\">DCL-aktuator Modbus-applikationsmanual<\/a><\/p><p><a href=\"\/da_dk\/stotte\/um-aktuator\/um-sf-zc-modbus\/\">F\u00e5 mere at vide<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4060921 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"4060921\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-78394cd\" data-id=\"78394cd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4f45092 elementor-widget elementor-widget-text-editor\" data-id=\"4f45092\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"\/da_dk\/content\/dam\/downloads\/app\/DLC_DC-FB3-v1.17.zip\/\" target=\"_blank\" rel=\"noopener\"><span style=\"text-decoration: underline;\">Download ops\u00e6tningssoftware<\/span><\/a><\/p><p><a href=\"\/da_dk\/um\/dc-fb1\/\" target=\"_blank\" rel=\"noopener\"><span style=\"text-decoration: underline;\">Se brugsanvisningen til DC-FB1<\/span><\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>DC-FB3-modulet, n\u00e5r det er installeret i den elektriske DCL-aktuator, giver mulighed for at styre ventilens position ved hj\u00e6lp af Modbus-TCP\/IP. Installationen er vist nedenfor: 1. Styring af DCL elektrisk aktuator via Modbus-TCP\/IP ved hj\u00e6lp af standardparametre DC-FB3 er forudkonfigureret i klienttilstand. Ved hj\u00e6lp af standardparametrene for MAC, IP, Gateway, Server og Port kan du styre [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[9],"tags":[],"class_list":["post-9257","post","type-post","status-publish","format-standard","hentry","category-um-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/posts\/9257","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/comments?post=9257"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/posts\/9257\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/media?parent=9257"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/categories?post=9257"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/tags?post=9257"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}