{"id":6393,"date":"2023-08-31T19:23:28","date_gmt":"2023-08-31T11:23:28","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6393"},"modified":"2025-03-31T07:02:40","modified_gmt":"2025-03-31T07:02:40","slug":"en15714-2-actuator-duty-classification","status":"publish","type":"post","link":"https:\/\/dclactuator.com\/da_dk\/stotte\/ts-aktuator\/en15714-2-aktuatorens-driftsklassificering","title":{"rendered":"EN15714-2 Klassificering af elektrisk aktuatorstyring (drift)"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6393\" class=\"elementor elementor-6393\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-c4425ee elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"c4425ee\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-592bf2f\" data-id=\"592bf2f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5ac9aa3 elementor-widget elementor-widget-image\" data-id=\"5ac9aa3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"646\" height=\"914\" src=\"https:\/\/dclactuator.com\/wp-content\/uploads\/2023\/08\/en15714-2-en.webp\" class=\"attachment-full size-full wp-image-6403\" alt=\"\u7535\u52a8\u6267\u884c\u5668\u63a7\u5236\u65b9\u5f0f(duty )\u7684\u5206\u7c7b\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2d2988c elementor-widget elementor-widget-text-editor\" data-id=\"2d2988c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2><strong>Kontrol af arbejdsklassifikationer:<\/strong><\/h2><ul><li><h4><strong>Klasse A: ON-OFF-type (t\u00e6nd\/sluk)<\/strong><\/h4><\/li><\/ul><ul><li style=\"list-style-type: none;\"><ul><li><p><strong>Funktion<\/strong>: Aktuatoren skal kunne drive ventilen gennem hele dens slagl\u00e6ngde fra helt \u00e5ben til helt lukket (og omvendt).<\/p><\/li><li><p><strong>Typisk brug<\/strong>: Anvendelser, hvor ventiler enten er helt \u00e5bne eller helt lukkede.<\/p><\/li><\/ul><\/li><li><h4><strong>Klasse B: Finjustering\/positionsjustering Type<\/strong><\/h4><ul><li><p><strong style=\"font-size: 16px;\">Funktion<\/strong><span style=\"font-size: 16px;\">: Aktuatoren flytter lejlighedsvis ventilen til en hvilken som helst position (helt \u00e5ben, mellemliggende eller helt lukket).<\/span><\/p><\/li><li><p><strong style=\"font-size: 16px;\">Typisk brug<\/strong><span style=\"font-size: 16px;\">: Anvendelser, der kr\u00e6ver lejlighedsvis justering, men ikke kontinuerlig bev\u00e6gelse.<\/span><\/p><\/li><\/ul><\/li><li><h4><strong>Klasse C: Modulerende type<\/strong><\/h4><ul><li><p><strong>Funktion<\/strong>: Aktuatoren flytter ofte ventilen mellem helt \u00e5bne og helt lukkede positioner.<\/p><\/li><li><p><strong>Typisk brug<\/strong>: Anvendelser, der kr\u00e6ver kontinuerlig og hyppig modulering af ventilpositionen.<\/p><\/li><\/ul><\/li><li><h4><strong>Klasse D: Kontinuerlig modulerende type<\/strong><\/h4><ul><li><p><strong>Funktion<\/strong>: Aktuatoren flytter kontinuerligt ventilen til en hvilken som helst position mellem helt \u00e5ben og helt lukket.<\/p><\/li><li><p><strong>Typisk brug<\/strong>: Anvendelser med kontinuerlige eller meget hyppige justeringer.<\/p><\/li><\/ul><\/li><\/ul><hr \/><h2><strong>Krav til aktuatorens livscyklus:<\/strong><\/h2><p>Aktuatorens design skal overholde de specificerede standarder for driftslevetid. For modulerende og kontinuerligt modulerende aktuatorer er deres holdbarhed baseret p\u00e5 kontinuerlige starter inden for 30% af deres slagl\u00e6ngde.<\/p><h4><strong>Test af levetid for part-turn-aktuatorer:<\/strong><\/h4><table><thead><tr><th>Omr\u00e5de for nominelt drejningsmoment (Nm)<\/th><th>Klasse A\/B (ON-OFF)<\/th><th>Klasse C (modulerende)<\/th><th>Klasse D (kontinuerligt modulerende)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 125<\/td><td>10.000 cyklusser<\/td><td>1.800.000 cyklusser<\/td><td>10.000.000 cyklusser<\/td><\/tr><tr><td>126-1000<\/td><td>10.000 cyklusser<\/td><td>1.200.000 cyklusser<\/td><td>10.000.000 cyklusser<\/td><\/tr><tr><td>1001-4000<\/td><td>5.000 cyklusser<\/td><td>500.000 cyklusser<\/td><td>5.000.000 cyklusser<\/td><\/tr><tr><td>4001-32000<\/td><td>5.000 cyklusser<\/td><td>250.000 cyklusser<\/td><td>Skal aftales<\/td><\/tr><tr><td>&gt; 32000<\/td><td>1.000 cyklusser<\/td><td>Skal aftales<\/td><td>Skal aftales<\/td><\/tr><\/tbody><\/table><ul><li><p><strong>Driftscyklusser<\/strong>: En cyklus omfatter to retninger med 90\u00b0 slagl\u00e6ngde (\u00e5ben 90\u00b0 + lukket 90\u00b0), baseret p\u00e5 mindst 30% gennemsnitlig belastning med nominelt drejningsmoment, med mindst 5% nominelt drejningsmoment i hver ende af slagl\u00e6ngden.<\/p><\/li><li><p><strong>Opstartscyklusser<\/strong>: En opstart indeb\u00e6rer at flytte aktuatoren mindst 1% af dens slagl\u00e6ngde med mindst 30% nominelt drejningsmoment.<\/p><\/li><\/ul><hr \/><h4><strong>Test af levetid for multi-turn-aktuatorer:<\/strong><\/h4><table><thead><tr><th>Omr\u00e5de for nominelt drejningsmoment (Nm)<\/th><th>Maks. tryk (kN)<\/th><th>Klasse A\/B (ON-OFF)<\/th><th>Klasse C (modulerende)<\/th><th>Klasse D (kontinuerligt modulerende)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 100<\/td><td>&lt;= 40<\/td><td>10.000 cyklusser<\/td><td>1.800.000 cyklusser<\/td><td>10.000.000 cyklusser<\/td><\/tr><tr><td>101-700<\/td><td>&lt;= 150<\/td><td>10.000 cyklusser<\/td><td>1.200.000 cyklusser<\/td><td>10.000.000 cyklusser<\/td><\/tr><tr><td>701-2500<\/td><td>&lt;= 325<\/td><td>5.000 cyklusser<\/td><td>500.000 cyklusser<\/td><td>5.000.000 cyklusser<\/td><\/tr><tr><td>2501-10000<\/td><td>&lt;= 1100<\/td><td>5.000 cyklusser<\/td><td>250.000 cyklusser<\/td><td>Skal aftales<\/td><\/tr><tr><td>&gt; 10000<\/td><td>&gt; 1100<\/td><td>1.000 cyklusser<\/td><td>Skal aftales<\/td><td>Skal aftales<\/td><\/tr><\/tbody><\/table><hr \/><h4><strong>Levetidstest af line\u00e6re aktuatorer:<\/strong><\/h4><table><thead><tr><th>Nominelt trykomr\u00e5de (kN)<\/th><th>Klasse A\/B (ON-OFF)<\/th><th>Klasse C (modulerende)<\/th><th>Klasse D (kontinuerligt modulerende)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 20<\/td><td>10.000 cyklusser<\/td><td>1.800.000 cyklusser<\/td><td>10.000.000 cyklusser<\/td><\/tr><tr><td>21-70<\/td><td>10.000 cyklusser<\/td><td>1.200.000 cyklusser<\/td><td>10.000.000 cyklusser<\/td><\/tr><tr><td>71-150<\/td><td>5.000 cyklusser<\/td><td>500.000 cyklusser<\/td><td>5.000.000 cyklusser<\/td><\/tr><tr><td>151-325<\/td><td>2.500 cyklusser<\/td><td>250.000 cyklusser<\/td><td>Skal aftales<\/td><\/tr><tr><td>&gt; 325<\/td><td>1.000 cyklusser<\/td><td>Skal aftales<\/td><td>Skal aftales<\/td><\/tr><\/tbody><\/table><hr \/><h2><strong>Krav til justeringsfrekvens (pr. time):<\/strong><\/h2><h4><strong>Part-Turn-aktuatorer:<\/strong><\/h4><table><thead><tr><th>Omr\u00e5de for nominelt drejningsmoment (Nm)<\/th><th>Klasse A (ON-OFF)<\/th><th>Klasse B (ON-OFF)<\/th><th>Klasse C (modulerende)<\/th><th>Klasse D (kontinuerligt modulerende)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 125<\/td><td>15 cyklusser\/time<\/td><td>120 starter\/time<\/td><td>1.200 starter\/time<\/td><td>3.600 starter\/time<\/td><\/tr><tr><td>126-1000<\/td><td>10 cyklusser\/time<\/td><td>60 starter\/time<\/td><td>600 starter\/time<\/td><td>1.800 starter\/time<\/td><\/tr><tr><td>1001-4000<\/td><td>5 cyklusser\/time<\/td><td>30 starter\/time<\/td><td>300 starter\/time<\/td><td>600 starter\/time<\/td><\/tr><tr><td>4001-32000<\/td><td>5 cyklusser\/time<\/td><td>15 starter\/time<\/td><td>60 starter\/time<\/td><td>N.A.<\/td><\/tr><tr><td>&gt; 32000<\/td><td>5 cyklusser\/time<\/td><td>5 starter\/time<\/td><td>30 starter\/time<\/td><td>N.A.<\/td><\/tr><\/tbody><\/table><hr \/><h4><strong>Multi-Turn-aktuatorer:<\/strong><\/h4><table><thead><tr><th>Omr\u00e5de for nominelt drejningsmoment (Nm)<\/th><th>Klasse A (ON-OFF)<\/th><th>Klasse B (ON-OFF)<\/th><th>Klasse C (modulerende)<\/th><th>Klasse D (kontinuerligt modulerende)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 100<\/td><td>15 minutter\/time<\/td><td>30 starter\/time<\/td><td>1.200 starter\/time<\/td><td>3.600 starter\/time<\/td><\/tr><tr><td>101-700<\/td><td>15 minutter\/time<\/td><td>20 starter\/time<\/td><td>600 starter\/time<\/td><td>1.800 starter\/time<\/td><\/tr><tr><td>701-2500<\/td><td>15 minutter\/time<\/td><td>15 starter\/time<\/td><td>300 starter\/time<\/td><td>600 starter\/time<\/td><\/tr><tr><td>2501-10000<\/td><td>15 minutter\/time<\/td><td>10 starter\/time<\/td><td>60 starter\/time<\/td><td>N.A.<\/td><\/tr><tr><td>&gt; 10000<\/td><td>15 minutter\/time<\/td><td>5 starter\/time<\/td><td>30 starter\/time<\/td><td>N.A.<\/td><\/tr><\/tbody><\/table><hr \/><h4><strong>Line\u00e6re aktuatorer:<\/strong><\/h4><table><thead><tr><th>Nominelt trykomr\u00e5de (kN)<\/th><th>Klasse A (ON-OFF)<\/th><th>Klasse B (ON-OFF)<\/th><th>Klasse C (modulerende)<\/th><th>Klasse D (kontinuerligt modulerende)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 20<\/td><td>15 cyklusser\/time<\/td><td>30 starter\/time<\/td><td>1.200 starter\/time<\/td><td>3.600 starter\/time<\/td><\/tr><tr><td>21-70<\/td><td>10 cyklusser\/time<\/td><td>15 starter\/time<\/td><td>600 starter\/time<\/td><td>1.800 starter\/time<\/td><\/tr><tr><td>&gt; 70<\/td><td>5 cyklusser\/time<\/td><td>5 starter\/time<\/td><td>30 starter\/time<\/td><td>TBA<\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-192baa1 elementor-widget elementor-widget-text-editor\" data-id=\"192baa1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Relevante standarder:<\/p><p><em>EN15714-1<\/em><\/p><p><em>EN 12570\uff0cIndustriventiler - Metode til bestemmelse af driftselementst\u00f8rrelse<\/em><br \/><em>EN 60529\uff0c\u5916\u58f3\u9632\u7b49\u7ea7\uff08IP\u4ee3\u7801\uff09\uff08IEC 60529:1989\uff09<\/em><br \/><em>EN ISO 5210:1996\uff0c\u5de5\u4e1a\u9600\u95e8--\u591a\u56de\u8f6c\u9600\u95e8\u6267\u884c\u673a\u6784\u9644\u4ef6\uff081SO 5210:1991\uff09<\/em><br \/><em>EN ISO 5211\uff0c\u5de5\u4e1a\u9600\u95e8-\u90e8\u5206\u56de\u8f6c\u9600\u95e8\u6267\u884c\u673a\u6784\u9644\u4ef6\uff08ISO 5211-2001\uff09<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Klassificering af kontrolopgaver: Klasse A: ON-OFF-type (On\/Off) Funktion: Aktuatoren skal drive ventilen gennem hele dens slagl\u00e6ngde fra helt \u00e5ben til helt lukket (og omvendt). Typisk anvendelse: Applikationer, hvor ventiler enten er helt \u00e5bne eller helt lukkede. Klasse B: Finjustering\/positionsjusteringstype Funktion: Aktuatoren flytter lejlighedsvis ventilen til [...]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[3],"tags":[53,66,57,52,55,65],"class_list":["post-6393","post","type-post","status-publish","format-standard","hentry","category-ts-actuator","tag-actuator","tag-explosion-proof-actuator","tag-general-actuator","tag-fast-move-actuator","tag-tech-ref","tag-very-small-actuator-tag"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/posts\/6393","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/comments?post=6393"}],"version-history":[{"count":0,"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/posts\/6393\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/media?parent=6393"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/categories?post=6393"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclactuator.com\/da_dk\/wp-json\/wp\/v2\/tags?post=6393"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}